Stator Winding Connection-Mode Management in Line-Start Permanent Magnet Motors to Improve Their Efficiency and Power Factor

被引:25
作者
Ferreira, Fernando J. T. E. [1 ,2 ]
Ge Baoming [3 ]
de Almeida, Anibal T. [2 ]
机构
[1] Polytech Inst Coimbra ISEC IPC, Dept Elect Engn, P-3030199 Coimbra, Portugal
[2] UC, ISR, P-3030290 Coimbra, Portugal
[3] Beijing Jiaotong Univ, Sch Elect Engn, Beijing 100044, Peoples R China
关键词
Efficiency; line-start permanent magnet motor (LSPM); multiflux motor; power factor; star/delta connections; stator winding connection mode; SYNCHRONOUS MOTORS; 3-PHASE; DESIGN;
D O I
10.1109/TEC.2013.2270084
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Three-phase line-start permanent magnet motors (LSPMs) are a recent entrance in the marketplace. In general, such motors are designed to meet IE4/Super-Premium Class requirements. As with squirrel-cage induction motors, LSPMs can benefit in terms of efficiency and power factor from a proper magnetizing flux adjustment as a function of their load. This is important to improve the motor performance when it is oversized and/or driving variable-load fixed-speed applications. In this paper, an experimental study on the improvement potential of steady-state partial-load efficiency and power factor in special multiconnection LSPMs with up to six different flux levels is presented. Some novel conclusions are offered regarding the efficiency and power factor gains and connection-mode management as a function of motor actual load, including the delta-star change in conventional six-terminal LSPMs. With the proposed solution, efficiency gains of 6-8% points and power factor gains of 0.4-0.5 points can be obtained in LSPMs at light partial loads, representing a very significant performance improvement. Moreover, it is demonstrated that reactive power injection into the mains grid is possible with LSPMs.
引用
收藏
页码:523 / 534
页数:12
相关论文
共 27 条
[1]  
BINGYI Z, 2007, PRESENTED AT THE INT
[2]   Adjustable Flux Three-Phase AC Machines With Combined Multiple-Step Star-Delta Winding Connections [J].
Cistelecan, Mihail V. ;
Ferreira, Fernando J. T. E. ;
Popescu, Mihail .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (02) :348-355
[3]  
de Albornoz A.D. C., 2012, ISSNIP Biosignals and Biorobotics Conference: Biosignals and Robotics for Better and Safer Living (BRC), P1, DOI [10.1109/BRC.2012.6222183, DOI 10.1109/BRC.2012.6222183]
[4]  
de Almeida A., 2005, P 4 INT C EN EFF MOT, VI, P149
[5]   STANDARDS FOR EFFICIENCY OF ELECTRIC MOTORS Permanent magnet synchronous motor technology [J].
de Almeida, Anibal T. ;
Ferreira, Fernando J. T. E. ;
Fong, Joao A. C. .
IEEE INDUSTRY APPLICATIONS MAGAZINE, 2011, 17 (01) :12-19
[6]  
DEALMEIDA A, 2013, P IEEE IND COMM POW, P1
[7]   Design and Analysis of Different Line-Start PM Synchronous Motors for Oil-Pump Applications [J].
Ding, Tingting ;
Takorabet, Noureddine ;
Sargos, Francois-Michel ;
Wang, Xiuhe .
IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (03) :1816-1819
[8]  
Ferreira F., 2011, 7 EN EFF MOT DRIV SY
[9]  
FERREIRA F, 2008, 18 INT C EL MACH VIL
[10]  
Ferreira F. J. T. E., 2009, 6 INT C EN EFF MOT D