Low-cost and portable MRI

被引:170
作者
Wald, Lawrence L. [1 ,2 ,3 ]
McDaniel, Patrick C. [1 ,4 ]
Witzel, Thomas [1 ,2 ]
Stockmann, Jason P. [1 ,2 ]
Cooley, Clarissa Zimmerman [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA USA
[2] Harvard Med Sch, Boston, MA 02115 USA
[3] Harvard Massachusetts Inst Technol, Div Hlth Sci & Technol, Cambridge, MA USA
[4] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
关键词
accessible MRI; low-cost MRI; MRI value; portable MRI; point-of-care MRI; RESONANCE-IMAGING SYSTEM; AMBULANCE-BASED THROMBOLYSIS; RESOLUTION NMR-SPECTROSCOPY; ACUTE ISCHEMIC-STROKE; RADIATION-EXPOSURE; MICROTESLA MRI; TOP NMR; FIELD; DESIGN; MOBILE;
D O I
10.1002/jmri.26942
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Research in MRI technology has traditionally expanded diagnostic benefit by developing acquisition techniques and instrumentation to enable MRI scanners to "see more." This typically focuses on improving MRI's sensitivity and spatiotemporal resolution, or expanding its range of biological contrasts and targets. In complement to the clear benefits achieved in this direction, extending the reach of MRI by reducing its cost, siting, and operational burdens also directly benefits healthcare by increasing the number of patients with access to MRI examinations and tilting its cost-benefit equation to allow more frequent and varied use. The introduction of low-cost, and/or truly portable scanners, could also enable new point-of-care and monitoring applications not feasible for today's scanners in centralized settings. While cost and accessibility have always been considered, we have seen tremendous advances in the speed and spatial-temporal capabilities of general-purpose MRI scanners and quantum leaps in patient comfort (such as magnet length and bore diameter), but only modest success in the reduction of cost and siting constraints. The introduction of specialty scanners (eg, extremity, brain-only, or breast-only scanners) have not been commercially successful enough to tilt the balance away from the prevailing model: a general-purpose scanner in a centralized healthcare location. Portable MRI scanners equivalent to their counterparts in ultrasound or even computed tomography have not emerged and MR monitoring devices exist only in research laboratories. Nonetheless, recent advances in hardware and computational technology as well as burgeoning markets for MRI in the developing world has created a resurgence of interest in the topic of low-cost and accessible MRI. This review examines the technical forces and trade-offs that might facilitate a large step forward in the push to "jail-break" MRI from its centralized location in healthcare and allow it to reach larger patient populations and achieve new uses. Technical Efficacy Stage:6 J. Magn. Reson. Imaging 2019. J. Magn. Reson. Imaging 2020;52:686-696.
引用
收藏
页码:686 / 696
页数:11
相关论文
共 96 条
[1]  
Anand S., 2018, A lowcost (andlt
[2]  
$500 USD) FPGAbased console capable of realtime control, P948
[3]   Economics, Helium, and the US Federal Helium Reserve: Summary and Outlook [J].
Anderson, Steven T. .
NATURAL RESOURCES RESEARCH, 2018, 27 (04) :455-477
[4]  
[Anonymous], [No title captured]
[5]  
[Anonymous], 2018, GLOBAL ULTRASOUND EQ
[6]   GARField magnetic resonance profiling of the ingress of model skin-care product ingredients into human skin in vitro [J].
Backhouse, L ;
Dias, M ;
Gorce, JP ;
Hadgraft, K ;
McDonald, PJ ;
Wiechers, JW .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2004, 93 (09) :2274-2283
[7]  
Blucher C, 2017, P 25 ANN M ISMRM HON, P1055
[8]   Desktop NMR and Its Applications From Materials Science To Organic Chemistry [J].
Bluemich, Bernhard ;
Singh, Kawarpal .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2018, 57 (24) :6996-7010
[9]   Noninvasive Testing of Art and Cultural Heritage by Mobile NMR [J].
Bluemich, Bernhard ;
Casanova, Federico ;
Perlo, Juan ;
Presciutti, Federica ;
Anselmi, Chiara ;
Doherty, Brenda .
ACCOUNTS OF CHEMICAL RESEARCH, 2010, 43 (06) :761-770
[10]  
Blümler P, 2016, NEW DEV NMR, V5, P133