A new quinoline-based chemosensor in ratiometric sensing of Hg2+ ions

被引:19
作者
Ghosh, Kumaresh [1 ]
Tarafdar, Debojyoti [1 ]
机构
[1] Univ Kalyani, Dept Chem, Kalyani 741235, Nadia, India
关键词
mercury recognition; zinc and cadmium sensing; quinoline-based receptor; ratiometric fluorescence; ratiometric absorbance; RESONANCE ENERGY-TRANSFER; TURN-ON PROBE; FLUORESCENT CHEMOSENSOR; AQUEOUS-SOLUTION; SELECTIVE DETECTION; RHODAMINE; HG(II); RECOGNITION; MOLECULE; RECEPTOR;
D O I
10.1080/10610278.2012.733818
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new quinoline-based chemosensor 1 has been designed and synthesised. Its metal ion-binding properties have been documented in organic and aqueous organic solvents. While chemosensor 1 recognises Hg2+ ions (K a=2.15x104M1) by exhibiting ratiometric change in emission in CHCl3/CH3OH (1:1, v/v), under similar condition both Zn2+ and Cd2+ ions are sensed by significant non-ratiometric increase in emission with measurable red shift. In DMSO/H2O (5:95, v/v), the sensor 1 exhibits a greater selectivity towards Hg2+ ions (K a=9.20x103M1) over the other metal ions examined.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 68 条
[31]   Fluorescent and colorimetric sensors for detection of lead, cadmium, and mercury ions [J].
Kim, Ha Na ;
Ren, Wen Xiu ;
Kim, Jong Seung ;
Yoon, Juyoung .
CHEMICAL SOCIETY REVIEWS, 2012, 41 (08) :3210-3244
[32]   Calixarene-derived fluorescent probes [J].
Kim, Jong Seung ;
Quang, Duong Tuan .
CHEMICAL REVIEWS, 2007, 107 (09) :3780-3799
[33]   Hyperbranched calixarenes: synthesis and applications as fluorescent probes [J].
Kim, Jong Seung ;
Lee, Su Yeon ;
Yoon, Juyoung ;
Vicens, Jacques .
CHEMICAL COMMUNICATIONS, 2009, (32) :4791-4802
[34]   Ratiometric determination of Hg2+ ions based on simple molecular motifs of pyrene and dioxaoctanediamide [J].
Kim, Jun Soo ;
Choi, Myung Gil ;
Song, Ki Cheol ;
No, Kyoung Tai ;
Ahn, Sangdoo ;
Chang, Suk-Kyu .
ORGANIC LETTERS, 2007, 9 (06) :1129-1132
[35]   New fluorescent and colorimetric chemosensors based on the rhodamine and boronic acid groups for the detection of Hg2+ [J].
Kim, Sook Kyung ;
Swamy, K. M. K. ;
Chung, So-Young ;
Kim, Ha Na ;
Kim, Min Jung ;
Jeong, Yongsuk ;
Yoon, Juyoung .
TETRAHEDRON LETTERS, 2010, 51 (25) :3286-3289
[36]   Highly sensitive and selective chemosensor for Hg2+ based on the rhodamine fluorophore [J].
Lee, Min Hee ;
Wu, Jia-Sheng ;
Lee, Jeong Won ;
Jung, Jong Hwa ;
Kim, Jong Seung .
ORGANIC LETTERS, 2007, 9 (13) :2501-2504
[37]   A selective fluorescent ratiometric chemodosimeter for mercury ion [J].
Liu, B ;
Tian, H .
CHEMICAL COMMUNICATIONS, 2005, (25) :3156-3158
[38]   Recognition of Hg2+ Using Diametrically Disubstituted Cyclam Unit [J].
Mahato, Prasenjit ;
Ghosh, Amrita ;
Saha, Sukdeb ;
Mishra, Sandhya ;
Mishra, Sanjiv K. ;
Das, Amitava .
INORGANIC CHEMISTRY, 2010, 49 (24) :11485-11492
[39]   METHYL MERCURY EXPOSURE IN NORTHERN QUEBEC .2. NEUROLOGIC FINDINGS IN CHILDREN [J].
MCKEOWNEYSSEN, GE ;
RUEDY, J ;
NEIMS, A .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1983, 118 (04) :470-479
[40]   Carbohydrate assisted fluorescence turn-on gluco-imino-anthracenyl conjugate as a Hg(II) sensor in milk and blood serum milieu [J].
Mitra, Atanu ;
Mittal, Ankit Kumar ;
Rao, Chebrolu Pulla .
CHEMICAL COMMUNICATIONS, 2011, 47 (09) :2565-2567