Surgical Approach and Hip Laterality Affect Accuracy of Acetabular Component Placement in Primary Total Hip Arthroplasty

被引:0
|
作者
Crawford, David A. [1 ]
Adams, Joanne B. [2 ]
Hobbs, Gerald R. [3 ]
Lombardi, Adolph V., Jr. [2 ,4 ,5 ,6 ]
Berend, Keith R. [2 ,4 ,5 ]
机构
[1] Joint Implant Surg, New Albany, OH 43054 USA
[2] Joint Implant Surg Inc, New Albany, OH USA
[3] West Virginia Univ, Dept Stat, Morgantown, WV USA
[4] White Fence Surg Suites, New Albany, OH USA
[5] Mt Carmel Hlth Syst, Columbus, OH USA
[6] Ohio State Univ, Dept Orthopaed, Wexner Med Ctr, Columbus, OH USA
来源
SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH | 2019年 / 35卷
关键词
DIRECT ANTERIOR APPROACH; MEASURING CUP ORIENTATION; INTRAOPERATIVE FLUOROSCOPY; POSTERIOR APPROACH; LEARNING-CURVE; SAFE ZONE; POSITION; REPLACEMENT; ANTEVERSION; DISLOCATIONS;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Controversy remains if the anterior approach improves acetabular component alignment, and many studies have compared approaches with different surgeons over different timeframes. The purpose of this study was to assess a single surgeon's experience over a one-year timeframe and radiographically compare acetabular component positioning with the direct anterior versus direct lateral approach. Secondarily, this study compares acetabular component position differences between right and left hips for a right-hand dominant surgeon. Materials and Methods: Postoperative radiographs of 289 primary total hip arthroplasties (THAs) performed by a single right-hand dominant surgeon in 2014 were reviewed for abduction, anteversion, and medial cup seating. Component position was compared to surgical approach with 152 direct anterior (DA) THAs (53%) and 137 direct lateral (DL) THAs (47%). The operative side was also compared to surgeon hand dominance. Surgeons target was 40 degrees abduction, 20 degrees anteversion +/- 5 degrees, and seating to the teardrop +/- 5mm. Lewinnek target was also assessed. Results: DA hips had a significantly lower abduction angle (p=0.04), less abduction target outliers (p<0.001), less abduction Lewinnek outliers (p<0.001), less target anteversion outliers (p<0.001), closer seating to teardrop (p<0.001), and less seating outliers (p<0.001). The combined target and Lewinnek safe zone were achieved more often in DA (p<0.001, p=0.042). Controlling for body mass index (BMI), the combined target achievement remained significantly better for DA (p=0.02), but combined Lewinnek was not significant (p=0.07). In the DA approach, right hips had a significantly lower abduction angle (p=0.03), less Lewinnek anteversion outliers (p=0.043), and less combined Lewinnek outliers (p=0.027). In the DL group, right hips had significantly higher anteversion angles (p=0.004) and Lewinnek anteversion outliers (p=0.033). Conclusion: The anterior approach improved target abduction, anteversion, and medialization compared to the direct lateral approach. Significant differences in component positioning were found in both approaches based on the surgeons dominant and non-dominant side.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The reliability and accuracy of measuring anteversion of the acetabular component on plain anteroposterior and lateral radiographs after total hip arthroplasty
    Shin, W. C.
    Lee, S. M.
    Lee, K. W.
    Cho, H. J.
    Lee, J. S.
    Suh, K. T.
    BONE & JOINT JOURNAL, 2015, 97B (05) : 611 - 616
  • [22] Acetabular and Femoral Component Positioning Using Direct Anterior Approach Versus Posterior Approach in Total Hip Arthroplasty
    Goyal, Tarun
    Choudhury, Arghya Kundu
    Paul, Souvik
    Gupta, Tushar
    Das, Lakshmana
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (05) : 1215 - 1224
  • [23] The accuracy of acetabular cup placement in primary total hip arthroplasty using an image-free navigation system
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [24] The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
    Park, Yang Soo
    Shin, Won Chul
    Lee, Sang Min
    Kwak, Sang Ho
    Bae, Jung Yun
    Suh, Kuen Tak
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [25] Accuracy and Precision of Version Angle Measurements of the Acetabular Component After Total Hip Arthroplasty
    Nishino, Hanae
    Nakamura, Shigeru
    Arai, Noriyuki
    Matsushita, Takashi
    JOURNAL OF ARTHROPLASTY, 2013, 28 (09) : 1644 - 1647
  • [26] Effect of Pelvic Obliquity on the Orientation of the Acetabular Component in Total Hip Arthroplasty
    Zhou, Xiaoxiao
    Wang, Qi
    Zhang, Xianlong
    Chen, Yunshu
    Shen, Hao
    Jiang, Yao
    JOURNAL OF ARTHROPLASTY, 2012, 27 (02) : 299 - 304
  • [27] Navigating the Reaming of the Acetabular Cavity in Total Hip Arthroplasty: Does it Improve Implantation Accuracy?
    Pagkalos, Joseph
    Chaudary, Muhammad Imran
    Davis, Edward T.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09) : 1749 - 1752
  • [28] Surgical Approaches for Total Hip Arthroplasty
    Vincent M Moretti
    Zachary D Post
    Indian Journal of Orthopaedics, 2017, 51 : 368 - 376
  • [29] Are Acetabular Component Alignment Guides for Total Hip Arthroplasty Accurate?
    Minoda, Yukihide
    Ohzono, Kenji
    Aihara, Masaharu
    Umeda, Naoya
    Tomita, Masuhiro
    Hayakawa, Keiko
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06) : 986 - 989
  • [30] Danish survey of acetabular component positioning practice during primary total hip arthroplasty
    Cotong, Dana
    Troelsen, Anders
    Husted, Henrik
    Gromov, Kirill
    DANISH MEDICAL JOURNAL, 2017, 64 (04):