Automated Office Blood Pressure is Associated with Urine Albumin Excretion in Hypertensive Subjects

被引:26
|
作者
Andreadis, Emmanuel A. [1 ]
Agaliotis, Gerasimos D. [1 ]
Angelopoulos, Epameinondas T. [1 ]
Tsakanikas, Athanasios P. [1 ]
Kolyvas, George N. [1 ]
Mousoulis, George P. [1 ]
机构
[1] Evangelismos Gen Hosp, Dept Internal Med 3, Athens, Greece
关键词
ambulatory blood pressure; arterial hypertension; automated office blood pressure; blood pressure; hypertension; microalbuminuria; urine albumin excretion; HOME; MICROALBUMINURIA; RECOMMENDATIONS; VALIDATION; MANAGEMENT; DEVICE; LOAD;
D O I
10.1038/ajh.2012.76
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
BACKGROUND We aimed to investigate the association between automated office blood pressure (AOBP) readings and urine albumin excretion (UAE), and to assess if this association is as close as that between 24-h ambulatory blood pressure (ABP) and UAE. A strong association would suggest that AOBP may serve as an indicator of early renal impairment. METHODS In a sample of 162 hypertensives, we compared AOBP with ABP measurements and their associations with UAE in two consecutive 24-h urine collections measured by an immunoturbidimetric assay. Microalbuminuria was defined as UAE of 30-300 mg/24 h. RESULTS The age of the subjects was 53 +/- 13 (mean +/- s.d.) years. Twenty-two were microalbuminuric. In those, AOBP and 24-h ABP were higher than in the normoalbuminuric subjects: 152 +/- 19 and 147 +/- 20 vs. 138 +/- 15 and 130 +/- 11 mm Hg for systolic blood pressure (SBP), and 97 +/- 15 and 92 +/- 14 vs. 86 +/- 10 and 82 +/- 8 mm Hg for diastolic blood pressure (DBP) (P < 0.001). Correlations between AOBP and 24-h ABP with log-transformed urine albumin were 0.30 (P < 0.001) and 0.43 (P < 0.001) for SBP and 0.27 (P < 0.001) and 0.33 (P < 0.001) for DBP. Adjusting for age, sex, body mass index, and estimated glomerular filtration rate, both AOBP and 24-h ABP were independently associated with urine albumin (P < 0.001 for both associations). Receiver operating characteristics curve analysis showed a similar predictive ability for microalbuminuria for AOBP and for 24-h ABP (area under the curve: 0.819 (P < 0.001) for SBP, 0.836 (P < 0.001) for DBP vs. 0.830 (P < 0.001) for SBP and 0.845 (P < 0.001) for DBP). CONCLUSIONS In this study, microalbuminuria correlated similarly with high-quality AOBP and ABP readings, further supporting the use of AOBP in the clinical setting.
引用
收藏
页码:969 / 973
页数:5
相关论文
共 50 条
  • [1] Automated Office Blood Pressure and 24-h Ambulatory Measurements are Equally Associated With Left Ventricular Mass Index
    Andreadis, Emmanuel A.
    Agaliotis, Gerasimos D.
    Angelopoulos, Epameinondas T.
    Tsakanikas, Athanasios P.
    Chaveles, Loannis A.
    Mousoulis, George P.
    AMERICAN JOURNAL OF HYPERTENSION, 2011, 24 (06) : 661 - 666
  • [2] Relationship of 24-h urinary sodium excretion with blood pressure, arterial distensibility, and urine albumin in Chinese hypertensive patients
    Sun, Ningling
    Xi, Yang
    Han, Weizhong
    Zhao, Lichao
    Wang, Hongyi
    Chen, Yuanyuan
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2015, 17 (0F) : F37 - F43
  • [3] Association of urinary albumin concentration with casual and ambulatory blood pressure: a similar relationship in normotensive and hypertensive subjects
    Gerber, LM
    Schwartz, JE
    Cedeno-Mero, C
    Warren, K
    Pickering, TG
    BLOOD PRESSURE MONITORING, 2001, 6 (05) : 245 - 251
  • [4] The relationship between sodium excretion and blood pressure, urine albumin, central retinal arteriolar equivalent
    Huang, Feng
    Yu, Peng
    Yuan, Yin
    Li, Qiaowei
    Lin, Fan
    Gao, Zhonghai
    Chen, Falin
    Zhu, Pengli
    BMC CARDIOVASCULAR DISORDERS, 2016, 16
  • [5] Comparative accuracies of automated and manual office blood pressure measurements in a Chinese population
    Lee, Eric K. P.
    Zhu, MengTing
    Chan, Dicken C. C.
    Yip, Benjamin H. K.
    McManus, Richard
    Wong, Samuel Y. S.
    HYPERTENSION RESEARCH, 2022, 45 (02) : 324 - 332
  • [6] Urine sodium excretion is related to extracellular water volume but not to blood pressure in 510 normotensive and never-treated hypertensive subjects
    Taurio, Jyrki
    Koskela, Jenni
    Sinisalo, Marjatta
    Tikkakoski, Antti
    Niemela, Onni
    Hamalainen, Mari
    Moilanen, Eeva
    Choudhary, Manoj Kumar
    Mustonen, Jukka
    Nevalainen, Pasi
    Porsti, Ilkka
    BLOOD PRESSURE, 2023, 32 (01)
  • [7] Transvascular albumin leakage and urinary albumin excretion in uncomplicated essential hypertensive subjects
    Pedrinelli, R
    Dell'Omo, G
    Penno, G
    Bandinelli, S
    Giorgi, D
    Di Bello, V
    Mariani, M
    AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (04) : 78A - 78A
  • [8] Automated office blood pressure measurements obtained with and without preceding rest are associated with awake ambulatory blood pressure
    Andreadis, Emmanuel A.
    Geladari, Charalampia V.
    Angelopoulos, Epameinondas T.
    JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (01) : 32 - 38
  • [9] Automated compared to manual office blood pressure and to home blood pressure in hypertensive patients
    Filipovsky, Jan
    Seidlerova, Jitka
    Kratochvil, Zdenek
    Karnosova, Petra
    Hronova, Marketa
    Mayer, Otto, Jr.
    BLOOD PRESSURE, 2016, 25 (04) : 228 - 234
  • [10] Automated office blood pressure measurement by elderly patients in the waiting room
    Toba, Ayumi
    Ishikawa, Joji
    Suzuki, Ayumi
    Harada, Kazumasa
    BLOOD PRESSURE MONITORING, 2021, 26 (05) : 321 - 327