Temperature mapping in bread dough using SE and GE two-point MRI methods: experimental and theoretical estimation of uncertainty

被引:11
作者
Lucas, Tiphaine [1 ]
Musse, Maja
Bornert, Melanie
Davenel, Armel
Quellec, Stephane
机构
[1] Irstea, Food Proc Engn Res Unit, F-35044 Rennes, France
关键词
MRI; Temperature mapping; T-1; Dough; Bread; Uncertainty; Food; NMR; RESONANCE FREQUENCY-SHIFT; ECHO SEQUENCE; T1; RELAXATION; FLIP ANGLES; FLASH MRI; T-1; THERMOMETRY; FERMENTATION; VALIDATION; ACCURATE;
D O I
10.1016/j.mri.2011.09.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two-dimensional (2D)-SE, 2D-GE and tri-dimensional (3D)-GE two-point T-1-weighted MRI methods were evaluated in this study in order to maximize the accuracy of temperature mapping of bread dough during thermal processing. Uncertainties were propagated throughout each protocol of measurement, and comparisons demonstrated that all the methods with comparable acquisition times minimized the temperature uncertainty to similar extent. The experimental uncertainties obtained with low-field MRI were also compared to the theoretical estimations. Some discrepancies were reported between experimental and theoretical values of uncertainties of temperature; however, experimental and theoretical trends with varying parameters agreed to a large extent for both SE and GE methods. The 2D-SE method was chosen for further applications on prefermented dough because of its lower sensitivity to susceptibility differences in porous media. It was applied for temperature mapping in prefermented dough during chilling prior to freezing and compared locally to optical fiber measurements. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:431 / 445
页数:15
相关论文
共 37 条
[1]  
[Anonymous], 1993, Guide to the Expression of Uncertainty in Measurement, V1st, P101
[2]   Continuous monitoring of dough fermentation and bread baking by magnetic resonance microscopy [J].
Bajd, Franci ;
Sersa, Igor .
MAGNETIC RESONANCE IMAGING, 2011, 29 (03) :434-442
[3]  
Bernstein MA., 2004, Handbook of MRI pulse sequences, P1017
[4]   Non-invasive temperature mapping using MRI:: Comparison of two methods based on chemical shift and T1-relaxation [J].
Bertsch, F ;
Mattner, J ;
Stehling, MK ;
Müller-Lisse, U ;
Peller, M ;
Loeffler, R ;
Weber, J ;
Messmer, K ;
Wilmanns, W ;
Issels, R ;
Reiser, M .
MAGNETIC RESONANCE IMAGING, 1998, 16 (04) :393-403
[5]   SPIN-LATTICE RELAXATION-TIME MEASUREMENT BY MEANS OF A TURBOFLASH TECHNIQUE [J].
BLUML, S ;
SCHAD, LR ;
STEPANOW, B ;
LORENZ, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :289-295
[6]   Simultaneous monitoring of temperature and T1:: Methods and preliminary results of application to drug delivery using thermosensitive liposomes [J].
Bos, C ;
Lepetit-Coiffé, M ;
Quesson, B ;
Moonen, CTW .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (04) :1020-1024
[7]   FAST AND PRECISE T1 IMAGING USING A TOMROP SEQUENCE [J].
BRIX, G ;
SCHAD, LR ;
DEIMLING, M ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :351-356
[8]  
Brookes JA, 1999, JMRI-J MAGN RESON IM, V9, P163, DOI 10.1002/(SICI)1522-2586(199902)9:2<163::AID-JMRI3>3.0.CO
[9]  
2-L
[10]  
Cauvain SP, 1998, TECHNOLOGY BREADMAKI, P149