Effects of urban morphology on anthropogenic heat dispersion in tropical high-density residential areas

被引:65
作者
Adelia, A. S. [1 ]
Yuan, C. [1 ]
Liu, L. [1 ]
Shan, R. Q. [1 ]
机构
[1] Natl Univ Singapore, Sch Design & Environm, Dept Architecture, Singapore, Singapore
关键词
Anthropogenic heat dispersion; Buoyancy effect; Building design; CFD; Urban heat island; WIND-TUNNEL; POLLUTANT DISPERSION; BUOYANT FLOWS; TEMPERATURE; BUILDINGS; TOKYO; VENTILATION; ENVIRONMENT; SIMULATION; SINGAPORE;
D O I
10.1016/j.enbuild.2019.01.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Anthropogenic heat is constantly emitted to the urban environment in which could trigger a vicious cycle: risen the air temperature, subsequently increase the cooling-energy consumption and further intensify the urban heat island effect. While extensive studies had been conducted to estimate the magnitude of anthropogenic heat emission in urban areas, research that investigates the behaviour of anthropogenic heat dispersion in the outdoor environment is limited. This research aims to understand the interaction between the airflow and the flux of heat rejected from the high-rise residential buildings, and effects of heat flux on the air temperature in the street canyon. Parametric study is performed by using Computational Fluid Dynamics (CFD) simulation method, and the results indicate that, emission position and building porosity play an important role in anthropogenic heat removal from the street canyon. Single strategy, such as building height variance, can help to reduce the street canyon temperature to some extents, but the impact can be more significant when it is coupled with other strategies. At the end, a case study is conducted to evaluate the practicability of the suggested mitigation strategies in real urban design practice. This study bridges the knowledge gap between the complex aerodynamic physics and the real urban planning and design practices. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:368 / 383
页数:16
相关论文
共 39 条
[1]   A wind tunnel study on three-dimensional buoyant flows in street canyons with different roof shapes and building lengths [J].
Allegrini, Jonas .
BUILDING AND ENVIRONMENT, 2018, 143 :71-88
[2]   Wind tunnel measurements of buoyant flows in street canyons [J].
Allegrini, Jonas ;
Dorer, Viktor ;
Carmeliet, Jan .
BUILDING AND ENVIRONMENT, 2013, 59 :315-326
[3]   Global to city scale urban anthropogenic heat flux: model and variability [J].
Allen, L. ;
Lindberg, F. ;
Grimmond, C. S. B. .
INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2011, 31 (13) :1990-2005
[4]  
[Anonymous], POP TRENDS 2016
[5]  
[Anonymous], FLUENT 12 US GUID
[6]  
[Anonymous], 2012, ANN EN REV 2011
[7]   Urban-scale CFD analysis in support of a climate-sensitive design for the Tokyo Bay area [J].
Ashie, Yasunobu ;
Kono, Takaaki .
INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2011, 31 (02) :174-188
[8]   Influence of a depth of a recessed space to flow due to air-conditioner heat rejection [J].
Bojic, M ;
Lee, M ;
Yik, F .
ENERGY AND BUILDINGS, 2002, 34 (01) :33-43
[9]   Flow and temperatures outside a high-rise residential building due to heat rejection by its air-conditioners [J].
Bojic, M ;
Lee, M ;
Yik, F .
ENERGY AND BUILDINGS, 2001, 33 (07) :737-751
[10]   Stuck in a stack-Temperature measurements of the microclimate around split type condensing units in a high rise building in Singapore [J].
Bruelisauer, Marcel ;
Meggers, Forrest ;
Saber, Esmail ;
Li, Cheng ;
Leibundgut, Hansjuerg .
ENERGY AND BUILDINGS, 2014, 71 :28-37