Heterogeneity of heterogeneous ion-exchange membranes investigated by chronopotentiometry and X-ray computed microtomography

被引:24
作者
Vobecka, Lucie [1 ]
Svoboda, Milos [1 ,2 ]
Benes, Jan [2 ]
Bellon, Tomas [1 ]
Slouka, Zdenek [1 ,2 ]
机构
[1] Univ Chem & Technol Prague, Dept Chem Engn, Tech 3, Prague 16628 6, Czech Republic
[2] Univ West Bohemia, New Technol Res Ctr, Univ 8, Plzen 30614, Czech Republic
关键词
Heterogeneous ion-exchange membrane; Ion-exchange resin particles; Chronopotentiometry; Sand equation; Structure; X-ray computed microtomography; CONCENTRATION POLARIZATION; ELECTRODIALYSIS MEMBRANES; TRANSITION TIME; CURRENT-RANGE; TRANSPORT; SURFACE; ELECTROCONVECTION; INHOMOGENEITY; MORPHOLOGY; VOLTAGE;
D O I
10.1016/j.memsci.2018.04.049
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Chronopotentiometry is a powerful experimental technique for characterization of ion-exchange membranes, especially phenomena associated with ion transport and the occurrence of overlimiting current. One also uses this technique to estimate heterogeneity of ion-exchange membranes, or more precisely the fractions of conductive and nonconductive regions in the membrane, by measuring so called transition times and their substitution into Sand equation. Here, we test this approach on small pieces of heterogeneous cation-and anion-exchange membranes by combining two experimental techniques, namely chronopotentiometry and X-ray computed microtomography. While chronopotentiometry provides data for the theoretical analysis based on Sand equation, microtomography provides a detailed analysis of the membrane structure both on its surface and in its volume. Such a structural analysis allows for evaluation of volumetric and surface fractions of ion-exchange resin and also quantification of the surface area of the active ion-exchange material on the depletion side of the membrane. We compare the experimental data from both techniques to see how they correlate and discuss the obtained results. We conduct the same experimental investigation on single ion-exchange resin particles which are a component of the aforementioned heterogeneous membranes. The ion-exchange particles can be viewed as homogeneous ion-exchange systems. Our structural analysis by means of the newly developed technique based on micro-computed tomography showed that the volume and the surface compositions of the heterogeneous membranes differ. The surface fraction of the ion-exchange resin is two to three times smaller than the corresponding volumetric fraction. The experimental transition times showed very good agreement with the predictions of the Sand equation in case of the ion-exchange particles. Unlike that the transition times were not well predicted by the Sand equation in case of the heterogeneous ion-exchange membranes. This fact along with observed differences in the structure of these membranes on their surface and in their volume limit the use of the Sand equation to estimate the content of the ion-exchange resin in these membranes.
引用
收藏
页码:127 / 137
页数:11
相关论文
共 50 条
  • [41] Kernel crack characteristics for X-ray computed microtomography (μCT) and their relationship with the breakage rate of maize varieties
    Dong Peng-fei
    Xie Rui-zhi
    Wang Ke-ru
    Ming Bo
    Hou Peng
    Hou Jun-feng
    Xue Jun
    Li Chao-hai
    Li Shao-kun
    JOURNAL OF INTEGRATIVE AGRICULTURE, 2020, 19 (11) : 2680 - 2689
  • [42] Analysis of the structural changes of a pellet/powder bentonite mixture upon wetting by X-ray computed microtomography
    Guerra, Agustin Molinero
    Aimedieu, Patrick
    Bornert, Michel
    Cui, Yu-Jun
    Tang, Anh Minh
    Sun, Zhao
    Mokni, Nadia
    Delage, Pierre
    Bernier, Frederic
    APPLIED CLAY SCIENCE, 2018, 165 : 164 - 169
  • [43] Acoustic emission and X-ray computed microtomography characterization of damage accumulation in a woven Cf/SiC composite
    Xue, Yudong
    Wang, Qinglei
    Hu, Jianbao
    Zhou, Haijun
    Shan, Qingliang
    Zhu, Guangxiang
    Kan, Yanmei
    Gao, Le
    Dong, Shaoming
    MATERIALS CHARACTERIZATION, 2019, 155
  • [44] Mapping Microscale Chemical Heterogeneity in Nafion Membranes with X-ray Photoelectron Spectroscopy
    Friedman, Alicia K.
    Shi, Wenqing
    Losovyj, Yaroslav
    Siedle, Allen R.
    Baker, Lane A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (11) : H733 - H741
  • [45] In Situ Characterization of Corrosion Processes of As-Extruded Pure Magnesium Using X-Ray Computed Microtomography
    Zhang, Chi
    Li, Xin
    Liu, Keli
    Tian, Guangyuan
    Wang, Shuo
    Wang, Junsheng
    CORROSION, 2022, 78 (04) : 350 - 358
  • [46] Combined beam hardening artifact correction and quantitative microanalysis of colloidal depositions in deep bed filtration experiments investigated by 3D X-ray computed microtomography
    Ilzig, Thomas
    Guenther, Stefan
    Odenbach, Stefan
    MICRON, 2022, 158
  • [47] X-Ray Computed Microtomography of Sulfide Minerals: Studies of Microinclusions and Implications for the Sm–Nd Dating of Ore Genesis
    P. A. Serov
    R. I. Kadyrov
    A. O. Kalashnikov
    Doklady Earth Sciences, 2022, 507 : S400 - S405
  • [48] Method for Obtaining Silver Nanoparticle Concentrations within a Porous Medium via Synchrotron X-ray Computed Microtomography
    Molnar, Ian L.
    Willson, Clinton S.
    O'Carroll, Denis M.
    Rivers, Mark L.
    Gerhard, Jason I.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (02) : 1114 - 1122
  • [49] Testing the X-ray computed microtomography on microfossil identification: An example from Sergipe-Alagoas Basin, Brazil
    Mouro, Lucas D.
    Vieira, Lucas D.
    Moreira, Anderson C.
    Piovesan, Enelise Katia
    Fernandes, Celso P.
    Fauth, Gerson
    Horodisky, Rodrigo S.
    Ghilardi, Renato Pirani
    Mantovani, Iara F.
    Baecker-Fauth, Simone
    Krahl, Guilherme
    Waichel, Breno Leitao
    da Silva, Mateus Souza
    JOURNAL OF SOUTH AMERICAN EARTH SCIENCES, 2021, 107
  • [50] BIODEGRADATION OF POROUS CALCIUM PHOSPHATE SCAFFOLDS IN AN ECTOPIC BONE FORMATION MODEL STUDIED BY X-RAY COMPUTED MICROTOMOGRAPHY
    Komlev, V. S.
    Mastrogiacomo, M.
    Pereira, R. C.
    Peyrin, F.
    Rustichelli, F.
    Cancedda, R.
    EUROPEAN CELLS & MATERIALS, 2010, 19 : 136 - 146