Heterogeneity of heterogeneous ion-exchange membranes investigated by chronopotentiometry and X-ray computed microtomography

被引:24
作者
Vobecka, Lucie [1 ]
Svoboda, Milos [1 ,2 ]
Benes, Jan [2 ]
Bellon, Tomas [1 ]
Slouka, Zdenek [1 ,2 ]
机构
[1] Univ Chem & Technol Prague, Dept Chem Engn, Tech 3, Prague 16628 6, Czech Republic
[2] Univ West Bohemia, New Technol Res Ctr, Univ 8, Plzen 30614, Czech Republic
关键词
Heterogeneous ion-exchange membrane; Ion-exchange resin particles; Chronopotentiometry; Sand equation; Structure; X-ray computed microtomography; CONCENTRATION POLARIZATION; ELECTRODIALYSIS MEMBRANES; TRANSITION TIME; CURRENT-RANGE; TRANSPORT; SURFACE; ELECTROCONVECTION; INHOMOGENEITY; MORPHOLOGY; VOLTAGE;
D O I
10.1016/j.memsci.2018.04.049
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Chronopotentiometry is a powerful experimental technique for characterization of ion-exchange membranes, especially phenomena associated with ion transport and the occurrence of overlimiting current. One also uses this technique to estimate heterogeneity of ion-exchange membranes, or more precisely the fractions of conductive and nonconductive regions in the membrane, by measuring so called transition times and their substitution into Sand equation. Here, we test this approach on small pieces of heterogeneous cation-and anion-exchange membranes by combining two experimental techniques, namely chronopotentiometry and X-ray computed microtomography. While chronopotentiometry provides data for the theoretical analysis based on Sand equation, microtomography provides a detailed analysis of the membrane structure both on its surface and in its volume. Such a structural analysis allows for evaluation of volumetric and surface fractions of ion-exchange resin and also quantification of the surface area of the active ion-exchange material on the depletion side of the membrane. We compare the experimental data from both techniques to see how they correlate and discuss the obtained results. We conduct the same experimental investigation on single ion-exchange resin particles which are a component of the aforementioned heterogeneous membranes. The ion-exchange particles can be viewed as homogeneous ion-exchange systems. Our structural analysis by means of the newly developed technique based on micro-computed tomography showed that the volume and the surface compositions of the heterogeneous membranes differ. The surface fraction of the ion-exchange resin is two to three times smaller than the corresponding volumetric fraction. The experimental transition times showed very good agreement with the predictions of the Sand equation in case of the ion-exchange particles. Unlike that the transition times were not well predicted by the Sand equation in case of the heterogeneous ion-exchange membranes. This fact along with observed differences in the structure of these membranes on their surface and in their volume limit the use of the Sand equation to estimate the content of the ion-exchange resin in these membranes.
引用
收藏
页码:127 / 137
页数:11
相关论文
共 50 条
  • [31] Development of Plant Roots Network in Polluted Soils: An X-ray Computed Microtomography Investigation
    Seignez, Nicolas
    Gauthier, Arnaud
    Mess, Florias
    Brunel, Celia
    Dubois, Michel
    Potdevin, Jean Luc
    WATER AIR AND SOIL POLLUTION, 2010, 209 (1-4) : 199 - 207
  • [32] Using X-ray Computed Microtomography for Investigation of the Morphology and Composition of the Hard Tooth Tissue
    Pikhur, Oksana L.
    Plotkina, Yulia, V
    Kulkov, Alexander M.
    PROCESSES AND PHENOMENA ON THE BOUNDARY BETWEEN BIOGENIC AND ABIOGENIC NATURE, 2020, : 221 - 232
  • [33] A new numerical modelling method for deformation behaviour of metallic porous materials using X-ray computed microtomography
    Doroszko, M.
    Seweryn, A.
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2017, 689 : 142 - 156
  • [34] Sesamoid Bones in Tuatara (Sphenodon punctatus) Investigated With X-Ray Microtomography, and Implications for Sesamoid Evolution in Lepidosauria
    Regnault, Sophie
    Hutchinson, John R.
    Jones, Marc E. H.
    JOURNAL OF MORPHOLOGY, 2017, 278 (01) : 62 - 72
  • [35] Transport Characteristics of Homogeneous and Heterogeneous Ion-Exchange Membranes in Sodium Chloride, Calcium Chloride, and Sodium Sulfate Solutions
    Sarapulova, V. V.
    Titorova, V. D.
    Nikonenko, V. V.
    Pismenskaya, N. D.
    MEMBRANES AND MEMBRANE TECHNOLOGIES, 2019, 1 (03) : 168 - 182
  • [36] Observation of the microstructural evolution of snow under uniaxial compression using X-ray computed microtomography
    Wang, Xuan
    Baker, Ian
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2013, 118 (22) : 12371 - 12382
  • [37] X-ray computed microtomography of threedimensional microcracks and self-healing in engineered cementitious composites
    Fan, Shuai
    Li, Mo
    SMART MATERIALS AND STRUCTURES, 2015, 24 (01)
  • [38] Morphological Evolution of Zn-Sponge Electrodes Monitored by In Situ X-ray Computed Microtomography
    Bozzini, Benedetto
    Mele, Claudio
    Veneziano, Alessio
    Sodini, Nicola
    Lanzafame, Gabriele
    Taurino, Antonietta
    Mancini, Lucia
    ACS APPLIED ENERGY MATERIALS, 2020, 3 (05) : 4931 - 4940
  • [39] Colloid deposition in monolithic porous media - Experimental investigations using X-ray computed microtomography and magnetic resonance velocimetry
    Mikolajczyk, Gerd
    Huang, Li
    Wilhelm, Michaela
    Dreher, Wolfgang
    Odenbach, Stefan
    CHEMICAL ENGINEERING SCIENCE, 2018, 175 : 257 - 266
  • [40] The formation of interlocked grain in African mahogany (Khaya spp.) analysed by X-ray computed microtomography
    Collings, David A.
    Thomas, Jimmy
    Dijkstra, Stephanie M.
    Harrington, Jonathan J.
    TREE PHYSIOLOGY, 2021, 41 (08) : 1542 - 1557