Dispersive micro solid-phase extraction for the rapid analysis of synthetic polycyclic musks using thermal desorption gas chromatography-mass spectrometry

被引:43
作者
Chung, Wu-Hsun [1 ,2 ]
Tzing, Shin-Hwa [2 ]
Ding, Wang-Hsien [1 ]
机构
[1] Natl Cent Univ, Dept Chem, Chungli 320, Taiwan
[2] Army Acad ROC, Dept Chem Engn, Chungli 320, Taiwan
关键词
Synthetic musks; Water analysis; Dispersive micro solid-phase extraction; Thermal desorption-GC-MS; LIQUID-LIQUID MICROEXTRACTION; PERSONAL-CARE PRODUCTS; WATER TREATMENT-PLANT; MAGNETIC NANOPARTICLES; AROMATIC-HYDROCARBONS; UV-FILTER; FRAGRANCES; SAMPLES; BIOACCUMULATION; NITROSAMINES;
D O I
10.1016/j.chroma.2013.07.074
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and solvent-free method for the rapid analysis of five synthetic polycyclic musks in water samples is described. The method involves the use of dispersive micro solid-phase extraction (D-mu-SPE) coupled with direct thermal desorption (TD) gas chromatography-mass spectrometry (GC-MS) operating in the selected-ion-storage (SIS) mode. The parameters affecting the extraction efficiency of the target analytes from water sample and the thermal desorption conditions in the GC injection-port were optimized using a central composite design method. The optimal extraction conditions involved immersing 3.2 mg of a typical octadecyl (C18) bonded silica adsorbent (i.e., ENVI-18) in a 10 mL water sample. After extraction by vigorously shaking for 1.0 min, the adsorbents were collected and dried on a filter. The adsorbents were transferred to a micro-vial, which was directly inserted into GC temperature-programmed injector, and the extracted target analytes were then thermally desorbed in the GC injection-port at 337 degrees C for 3.8 min. The limits of quantitation (LOQs) were determined to be 1.2-3.0 ng/L Precision, as indicated by relative standard deviations (RSDs), was less than 9% for both intra- and inter-day analysis. Accuracy, expressed as the mean extraction recovery, was between 74 and 90%. A preliminary analysis of the river water samples revealed that galaxolide (HHCB) and tonalide (AHTN) were the two most common synthetic polycyclic musks present. Using a standard addition method, their concentrations were determined to in the range from 11 to 140 ng/L. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 41 条
[1]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[2]  
[Anonymous], 1998, EURACHEM GUID FITN P
[3]   Multi-walled carbon nanotubes-dispersive solid-phase extraction combined with nano-liquid chromatography for the analysis of pesticides in water samples [J].
Asensio-Ramos, Maria ;
D'Orazio, Giovanni ;
Hernandez-Borges, Javier ;
Rocco, Anna ;
Fanali, Salvatore .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (04) :1113-1123
[4]   Development and application of porous membrane-protected carbon nanotube micro-solid-phase extraction combined with gas chromatography/mass spectrometry [J].
Basheer, C ;
Ainedhary, AA ;
Rao, BSM ;
Valliyaveettil, S ;
Lee, HK .
ANALYTICAL CHEMISTRY, 2006, 78 (08) :2853-2858
[5]   Analysis of musk fragrances in environmental samples [J].
Bester, Kai .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (03) :470-480
[6]   Estrogenic activity of musk fragrances detected by the E-screen assay using human MCF-7 cells [J].
Bitsch, N ;
Dudas, C ;
Körner, W ;
Failing, K ;
Biselli, S ;
Rimkus, G ;
Brunn, H .
ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2002, 43 (03) :257-264
[7]   Liquid chromatography-UV determination and liquid chromatography-atmospheric pressure chemical ionization mass spectrometric characterization of sitosterol and stigmasterol in soybean oil [J].
Careri, M ;
Elviri, L ;
Mangia, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 935 (1-2) :249-257
[8]   Orthogonal array optimization of microwave-assisted derivatization for determination of trace amphetamine and methamphetamine using negative chemical ionization gas chromatography-mass spectrometry [J].
Chung, Li-Wen ;
Lin, Keh-Liang ;
Yang, Thomas Ching-Cherng ;
Lee, Maw-Rong .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) :4083-4089
[9]   Membrane-assisted liquid-liquid extraction coupled with gas chromatography-mass spectrometry for determination of selected polycyclic musk compounds and drugs in water samples [J].
Einsle, T. ;
Paschke, H. ;
Bruns, K. ;
Schrader, S. ;
Popp, P. ;
Moeder, M. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1124 (1-2) :196-204
[10]   Nitromusk compounds in women with gynecological and endocrine dysfunction [J].
Eisenhardt, S ;
Runnebaum, B ;
Bauer, K ;
Gerhard, I .
ENVIRONMENTAL RESEARCH, 2001, 87 (03) :123-130