Detection of ultra-low concentration acetylene gas dissolved in oil based on fiber-optic photoacoustic sensing

被引:36
作者
Chen, Ke [1 ]
An, Ran [1 ]
Li, Chenxi [1 ]
Kang, Yuan [1 ]
Ma, Fengxiang [2 ]
Zhao, Xinyu [1 ]
Guo, Min [1 ]
Qi, Hongchao [1 ]
Zhao, Jikuan [1 ]
机构
[1] Dalian Univ Technol, Sch Optoelect Engn & Instrumentat Sci, Dalian 116024, Liaoning, Peoples R China
[2] State Grid Anhui Elect Power Co Ltd, Elect Power Res Inst, Hefei 230601, Anhui, Peoples R China
关键词
Photoacoustic spectroscopy; Optical fiber acoustic sensor; Dissolved gas analysis; Ultra-low concentration gas detection; TRACE-GAS; SENSOR; SPECTROSCOPY; CO;
D O I
10.1016/j.optlastec.2022.108299
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dissolved acetylene gas in oil is the characteristic gas to distinguish overheating and discharge faults of transformer. To realize the detection of ultra-low concentration acetylene in transformer oil, a photoacoustic (PA) gas detection system based on ultra-high sensitive fiber-optic acoustic sensing technique was designed. In order to amplify the power of the laser, an Erbium-doped fiber amplifier (EDFA) was utilized, thereby increasing the intensity of the PA excitation signal. A cantilever based fiber-optic acoustic sensor was utilized to detect the generated PA signal. the interference of carbon dioxide and water vapor on the detection of ultra-low concentration acetylene was studied through analyzing the absorption spectrum. By optimizing the laser modulation parameters, the interference of the interfering gases on the acetylene absorption signal is reduced. Experimental results show that the response time of the system is 9 min with the headspace degassing based oil-gas separation method. The ultra-low concentration of dissolved acetylene gas in oil was tested, and the detection limit reached 0.05 mu L/L. The technical solution provides a new solution for transformer fault detection.
引用
收藏
页数:7
相关论文
共 42 条
[21]   Acoustic microresonator based in-plane quartz-enhanced photoacoustic spectroscopy sensor with a line interaction mode [J].
Lang, Ziting ;
Qiao, Shunda ;
Ma, Yufei .
OPTICS LETTERS, 2022, 47 (06) :1295-1298
[22]   Compact TDLAS based optical sensor for ppb-level ethane detection by use of a 3.34 μm room-temperature CW interband cascade laser [J].
Li, Chunguang ;
Dong, Lei ;
Zheng, Chuantao ;
Tittel, Frank K. .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 232 :188-194
[23]   First-Principle Insight into the Ru-Doped PtSe2 Monolayer for Detection of H2 and C2H2 in Transformer Oil [J].
Li, Dajian ;
Rao, Xiajin ;
Zhang, Lei ;
Zhang, Yubo ;
Ma, Shouxiao ;
Chen, Liangyuan ;
Yu, Zhangting .
ACS OMEGA, 2020, 5 (49) :31872-31879
[24]   Resonant photoacoustic detection of trace gas with DFB diode laser [J].
Li, Jingsong ;
Gao, Xiaoming ;
Fang, Li ;
Zhang, Weijun ;
Cha, Hyungki .
OPTICS AND LASER TECHNOLOGY, 2007, 39 (06) :1144-1149
[25]   Sensitive methane detection based on quartz-enhanced photoacoustic spectroscopy with a high-power diode laser and wavelet filtering [J].
Li, Yu ;
Wang, Ruozhu ;
Tittel, Frank K. ;
Ma, Yufei .
OPTICS AND LASERS IN ENGINEERING, 2020, 132
[26]   Optical fiber tip-based quartz-enhanced photoacoustic sensor for trace gas detection [J].
Li, Zhili ;
Wang, Zhen ;
Wang, Chao ;
Ren, Wei .
APPLIED PHYSICS B-LASERS AND OPTICS, 2016, 122 (05)
[27]   Design and structural optimization of T-resonators for highly sensitive photoacoustic trace gas detection [J].
Liu, Lixian ;
Huan, Huiting ;
Mandelis, Andreas ;
Zhang, Le ;
Guo, Chengfei ;
Li, Wei ;
Zhang, Xueshi ;
Yin, Xukun ;
Shao, Xiaopeng ;
Wang, Duantian .
OPTICS AND LASER TECHNOLOGY, 2022, 148
[28]   Quartz-tuning-fork enhanced photothermal spectroscopy for ultra-high sensitive trace gas detection [J].
Ma, Yufei ;
He, Ying ;
Tong, Yao ;
Yu, Xin ;
Tittel, Frank K. .
OPTICS EXPRESS, 2018, 26 (24) :32103-32110
[29]   Quartz Enhanced Photoacoustic Spectroscopy Based Trace Gas Sensors Using Different Quartz Tuning Forks [J].
Ma, Yufei ;
Yu, Guang ;
Zhang, Jingbo ;
Yu, Xin ;
Sun, Rui ;
Tittel, Frank K. .
SENSORS, 2015, 15 (04) :7596-7604
[30]   QEPAS based ppb-level detection of CO and N2O using a high power CW DFB-QCL [J].
Ma, Yufei ;
Lewicki, Rafal ;
Razeghi, Manijeh ;
Tittel, Frank K. .