IN-SITU PH VALUE MONITORING SYSTEM OF CONCRETE PORE SOLUTION

被引:0
作者
Zhou, Huaxin [1 ]
Liu, Jiaping [1 ]
Sha, Jianfang [1 ]
Mu, Ru [1 ]
机构
[1] Jiangsu Inst Bldg Sci Co Ltd, Nanjing, Peoples R China
来源
MICROSTRUCTURE RELATED DURABILITY OF CEMENTITIOUS COMPOSITES, VOLS 1 AND 2 | 2008年 / 61卷
关键词
D O I
暂无
中图分类号
TB33 [复合材料];
学科分类号
摘要
A new auto-logger system device of Open-circuit potential(OCP) was introduced in this paper, a method of melt-oxidation at high temperature was adopted to fabricate Ir/IrOx pH electrode, the new auto-logger and in-situ pH value monitoring system for use in cement based porous materials has been invented and tested in solution and in concrete blocks. The results show that the Ir/IrOx pH electrode have excellent sensing, which follow the Nernst law with good linearity in a pH range from 2.0 to 14.0, and have a good long-term stability in alkaline medium. The pH values of concrete pore solution measured by in-situ monitoring system is in good quantitative agreement with that determined by pore solution expression method. The In-situ monitoring system can collect the date and supply useful information to durability evaluation of reinforced concrete.
引用
收藏
页码:1431 / +
页数:3
相关论文
共 20 条
[1]   EXPRESSION AND ANALYSIS OF PORE FLUIDS FROM HARDENED CEMENT PASTES AND MORTARS [J].
BARNEYBACK, RS ;
DIAMOND, S .
CEMENT AND CONCRETE RESEARCH, 1981, 11 (02) :279-285
[2]   Methods of obtaining pore solution from cement pastes and mortars for chloride analysis [J].
Buckley, L. J. ;
Carter, M. A. ;
Wilson, M. A. ;
Scantlebury, J. D. .
CEMENT AND CONCRETE RESEARCH, 2007, 37 (11) :1544-1550
[3]  
CARLOS A, 2002, CEMENT CONCRETE RES, V32, P973
[4]  
CHEN DC, 2003, T NONFERR METAL SOC, P1459
[5]  
COSTA CR, 2008, HAZARDOUS MAT, V153, P616
[6]   ELECTRONIC SEMICONDUCTING OXIDES AS PH SENSORS [J].
FOG, A ;
BUCK, RP .
SENSORS AND ACTUATORS, 1984, 5 (02) :137-146
[7]  
FREDRIK P, 1999, CEMENT CONCRETE RES, V29, P1863
[8]   Thin-film IrOx pH microelectrode for microfluidic-based microsystems [J].
Ges, IA ;
Ivanov, BL ;
Schaffer, DK ;
Lima, EA ;
Werdich, AA ;
Baudenbacher, FJ .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (02) :248-256
[9]   In situ monitoring of pH level with fiber optic evanescent field spectroscopy [J].
Ghandehari, M ;
Vimer, CS .
NDT & E INTERNATIONAL, 2004, 37 (08) :611-616
[10]   A method of reducing oxygen induced drift in iridium oxide pH sensors [J].
Hendrikse, J ;
Olthuis, W ;
Bergveld, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (1-2) :97-103