Metal-on-Metal Hip Resurfacing Radiographic Evaluation Techniques

被引:12
作者
Ramakrishnan, Raina [1 ]
Jaffe, William L. [2 ]
Kennedy, William R. [3 ]
机构
[1] Stryker Orthopaed, Dept Clin Res, Mahwah, NJ 07430 USA
[2] NYU, Hosp Joint Dis, Dept Orthopaed Surg, New York, NY USA
[3] Kennedy White Ortho Ctr, Sarasota, FL USA
关键词
hip resurfacing; metal-on-metal; radiographic analysis; femoral component subsidence; neck impingement;
D O I
10.1016/j.arth.2007.09.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hip surfacing devices require a new radiographic evaluation technique owing to femoral components with short or no stems. Fourteen US surgeons implanted 1148 metal-on-metal hip resurfacing (HR) devices in a US-FDA-IDE clinical trial, which began in 2001. In this multi-center, prospective Study, 337 patients (mean age, 50.1 years) were enrolled as a Study group of unilateral HR arthroplasties. Radiographs of 292 HR arthroplasties at a minimum 2-year follow-up (maximum 3 years) were reviewed. There were 10 patients with radiographic evidence of femoral component instability beyond 2 years, as evidenced by subsidence >= 5mm. of these, 7 did not have clinical symptoms associated with femoral component instability. in the Study group, 24 revisions were reported, of which 8 were due to femoral neck fractures, 4 were due to acetabular component loosening, 11 Were Clue to femoral component loosening, and 1 due to dislocation.
引用
收藏
页码:1099 / 1104
页数:6
相关论文
共 11 条
  • [1] Metal-on-metal hybrid surface arthroplasty:: Two to six-year follow-up study
    Amstutz, HC
    Beaulé, PE
    Dorey, FJ
    Le Duff, MJ
    Campbell, PA
    Gruen, TA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) : 28 - 39
  • [2] [Anonymous], 1979, CLIN ORTHOP RELAT RE
  • [3] EBRA-FCA for measurement of migration of the femoral component in surface arthroplasty of the hip
    Beaulé, PE
    Krismer, M
    Mayrhofer, P
    Wanner, S
    Le Duff, M
    Mattesich, M
    Stoeckl, B
    Amstutz, HC
    Biedermann, R
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (05): : 741 - 744
  • [4] Beaulé PE, 2004, CLIN ORTHOP RELAT R, P87
  • [5] Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement
    Biedermann, R
    Krismer, M
    Stöckl, B
    Mayrhofer, P
    Ornstein, E
    Franzén, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (02): : 266 - 272
  • [6] ECTOPIC OSSIFICATION FOLLOWING TOTAL HIP-REPLACEMENT - INCIDENCE AND A METHOD OF CLASSIFICATION
    BROOKER, AF
    BOWERMAN, JW
    ROBINSON, RA
    RILEY, LH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1973, A 55 (08) : 1629 - 1632
  • [7] DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
  • [9] NONPARAMETRIC-ESTIMATION FROM INCOMPLETE OBSERVATIONS
    KAPLAN, EL
    MEIER, P
    [J]. JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1958, 53 (282) : 457 - 481
  • [10] The effect of femoral rotation on the projected femoral neck-shaft angle
    Kay, RM
    Jaki, KA
    Skaggs, DL
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2000, 20 (06) : 736 - 739