Myocardial perfusion imaging with 13N-Ammonia PET is a strong predictor for outcome

被引:28
|
作者
Fiechter, Michael [1 ,2 ]
Gebhard, Catherine [1 ]
Ghadri, Jelena R. [1 ]
Fuchs, Tobias A. [1 ]
Pazhenkottil, Aju P. [1 ]
Nkoulou, Rene N. [1 ]
Herzog, Bernhard A. [1 ]
Altorfer, Ulrich [1 ]
Gaemperli, Oliver [1 ]
Kaufmann, Philipp A. [1 ,2 ]
机构
[1] Univ Zurich Hosp, Dept Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Zurich Ctr Integrat Human Physiol ZIHP, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Positron emission tomography; N-13-ammonia; Myocardial perfusion imaging; Outcome; POSITRON-EMISSION-TOMOGRAPHY; CORONARY-ARTERY-DISEASE; PROGNOSTIC VALUE; CLINICAL-OUTCOMES; FLOW RESERVE; IMPACT; QUANTIFICATION; CARDIOMYOPATHY; SPECT;
D O I
10.1016/j.ijcard.2012.03.076
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/objectives: The aim of the present study was to assess the long-term predictive value of myocardial perfusion imaging (MPI) with N-13-ammonia positron emission tomography (PET) in patients with suspected myocardial perfusion abnormality. At present, outcome data on the predictive value of MPI in N-13-ammonia PET exist only for rather small patient populations. Methods: Cardiac perfusion was assessed in 943 consecutive patients using N-13-ammonia PET, and follow-up was obtained in 698 (74%). 77 patients who underwent early revascularization (<60 days) were excluded and 621 patients were assigned to normal versus abnormal perfusion for outcome analysis. Hard events (cardiac death and non-fatal myocardial infarction) and major adverse cardiac events (MACE; hard events, hospitalization for cardiac reasons and late revascularization) were investigated using the Kaplan-Meier method. Independent predictors for various cardiac events were identified using Cox proportional hazard regression analysis. Results: During follow-up (5.7 +/- 2.5 years), 275 patients had at least 1 cardiac event, including 102 cardiac deaths and 33 non-fatal myocardial infarction. Abnormal perfusion (n=469) was associated with a higher incidence of MACE (P<0.001) and hard events (P<0.001) throughout the 10-year follow-up period. Conclusions: Cardiac perfusion findings in N-13-ammonia PET are strong predictors of long-term outcome. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1023 / 1026
页数:4
相关论文
共 50 条
  • [1] 13N-Ammonia PET/MR myocardial stress perfusion imaging early experience
    Lau, Jeffrey
    Laforest, Richard
    Zheng, Jie
    Lesniak, Donna
    Priatna, Agus
    Gropler, Robert
    Woodard, Pamela
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [2] A fast nonlinear method for parametric imaging of myocardial perfusion by dynamic 13N-ammonia PET
    Golish, SR
    Hove, JD
    Schelbert, HR
    Gambhir, SS
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (06) : 924 - 931
  • [3] Myocardial perfusion reserve compared with peripheral perfusion reserve: A 13N-ammonia PET study
    Scholtens, Asbjorn M.
    Dierckx, Rudi
    Tio, Rene
    Willems, Antoon T. M.
    Zeebregts, Clark
    Boersma, Hendrikus H.
    Glaudemans, Andor W. J. M.
    Slart, Riemer H. J. A.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [4] Influence of arm positioning on myocardial accumulation and myocardial blood flow in rest and stress 13N-ammonia PET myocardial perfusion imaging
    Kojima, Akihiro
    Ohshima, Satoru
    Tamai, Shin-ichi
    Nishio, Masami
    Tamaki, Tsuneo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [5] PET Imaging of cerebral astrocytoma with 13N-ammonia
    Zhang, Xiangsong
    Liang, Changhong
    Chen, Weian
    Zhou, Dong
    JOURNAL OF NEURO-ONCOLOGY, 2006, 78 (02) : 145 - 151
  • [6] Influence of arm positioning on myocardial accumulation and myocardial blood flow in rest and stress 13N-ammonia PET myocardial perfusion imaging
    Kojima, Akihiro
    Ohshima, Satoru
    Tamai, Shin-ichi
    Nishio, Masami
    Tamaki, Tsuneo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [7] Diagnostic Value of 13N-Ammonia Myocardial Perfusion PET: Added Value of Myocardial Flow Reserve
    Fiechter, Michael
    Ghadri, Jelena R.
    Gebhard, Catherine
    Fuchs, Tobias A.
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Herzog, Bernhard A.
    Wyss, Christophe A.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (08) : 1230 - 1234
  • [8] PET Imaging of cerebral astrocytoma with 13N-ammonia
    Zhang Xiangsong
    Liang Changhong
    Chen Weian
    Zhou Dong
    Journal of Neuro-Oncology, 2006, 78 : 145 - 151
  • [9] Diagnostic accuracy of 13N-ammonia myocardial perfusion imaging with PET-CT in the detection of coronary artery disease
    Fathala, Ahmed
    Aboulkheir, Mervat
    Shoukri, Mohamamed M.
    Alsergani, Hani
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2019, 9 (01) : 35 - 42
  • [10] Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging
    Nina Burkhard
    Bernhard A. Herzog
    Lars Husmann
    Aju P. Pazhenkottil
    Irene A. Burger
    Ronny R. Buechel
    Ines Valenta
    Christophe A. Wyss
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 517 - 521