The effect of the degradation pattern of biodegradable bone plates on the healing process using a biphasic mechano-regulation theory

被引:8
作者
Kowsar, Sara [1 ]
Soheilifard, Reza [1 ]
机构
[1] Hakim Sabzevari Univ, Dept Mech Engn, Sabzevar, Iran
关键词
Finite element analysis; Healing performance; Bioabsorbable bone plates; Tissue differentiation; Degradation pattern; TISSUE DIFFERENTIATION; DISTAL RADIUS; POLYMER-COMPOSITE; FRACTURE; MAGNESIUM; MODEL; FIXATION; ALLOYS; OPTIMIZATION; HISTORY;
D O I
10.1007/s10237-020-01386-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Bone plates are used to treat bone fractures by stabilizing the fracture site and allowing treatments to take place. Mechanical properties of the applied bone plate determine the stability of the fracture site and affect the endochondral ossification process and the healing performance. In recent years, biodegradable bone plates have been used in demand for the elimination of a second surgery to remove the plate. The degradation of these plates into the body environment is commonly accompanied by alterations in the mechanical properties of the bone plate and a shift in the healing performance of the bone. In the present study, the effects of using biodegradable plates with various elastic moduli and degradation patterns, including linear and nonlinear, on the healing process are investigated. A three-dimensional finite element model of the radius bone along with a mechano-regulation theory was used to study the healing performance. Two mechanical stimuli of octahedral shear strain and interstitial fluid flow are considered as the propelling factors of healing. The results of this study indicated that increasing the bone plate's initial elastic modulus accelerates the healing process. However, by increasing the initial Young's modulus of the plate more than 100 GPa, no noticeable alteration is observed. The degradation time period of the plate was seen to be directly related to the speed of the healing process. It is shown, however, that by increasing the degradation time period to more than 8 weeks, the healing performance remains almost unchanged. The results of this work showed that the application of plates with a high enough initial elastic modulus and degradation period can prevent the healing process from decelerating.
引用
收藏
页码:309 / 321
页数:13
相关论文
共 48 条
  • [1] [Anonymous], 2017, ARTICLE INFORM PROCE
  • [2] [Anonymous], 2011, BIOMATERIALS ORTHOPE
  • [3] A model of tissue differentiation and bone remodelling in fractured vertebrae treated with minimally invasive percutaneous fixation
    Boccaccio, A.
    Kelly, D. J.
    Pappalettere, C.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (09) : 947 - 959
  • [4] CORRELATIONS BETWEEN MECHANICAL-STRESS HISTORY AND TISSUE DIFFERENTIATION IN INITIAL FRACTURE-HEALING
    CARTER, DR
    BLENMAN, PR
    BEAUPRE, GS
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (05) : 736 - 748
  • [5] In vivo study of magnesium plate and screw degradation and bone fracture healing
    Chaya, Amy
    Yoshizawa, Sayuri
    Verdelis, Kostas
    Myers, Nicole
    Costello, Bernard J.
    Chou, Da-Tren
    Pal, Siladitya
    Maiti, Spandan
    Kumta, Prashant N.
    Sfeir, Charles
    [J]. ACTA BIOMATERIALIA, 2015, 18 : 262 - 269
  • [6] Design optimisation and experimental evaluation of dorsal double plating fixation for distal radius fracture
    Chen, Alvin Chao-Yu
    Lin, Yu-Hao
    Kuo, Hsien-Nan
    Yu, Tsung-Chih
    Sun, Ming-Tsung
    Lin, Chun-Li
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04): : 527 - 534
  • [7] Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing
    Claes, LE
    Heigele, CA
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (03) : 255 - 266
  • [8] Cook SD, 1997, CLIN ORTHOP RELAT R, P198
  • [9] Bioresorbable screws reinforced with phosphate glass fibre: Manufacturing and mechanical property characterisation
    Felfel, R. M.
    Ahmed, I.
    Parsons, A. J.
    Rudd, C. D.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 17 : 76 - 88
  • [10] Initial mechanical properties of phosphate-glass fibre-reinforced rods for use as resorbable intramedullary nails
    Felfel, R. M.
    Ahmed, I.
    Parsons, A. J.
    Harper, L. T.
    Rudd, C. D.
    [J]. JOURNAL OF MATERIALS SCIENCE, 2012, 47 (12) : 4884 - 4894