Influence of hydrostatic pressure on intracoronary indices of stenosis severity in vivo

被引:10
作者
Haerle, Tobias [1 ]
Luz, Mareike [1 ]
Meyer, Sven [1 ]
Vahldiek, Felix [1 ]
van der Harst, Pim [2 ,3 ]
van Dijk, Randy [2 ,3 ]
Ties, Daan [2 ,3 ]
Escaned, Javier [4 ]
Davies, Justin [5 ]
Elsaesser, Albrecht [1 ]
机构
[1] Carl von Ossietzky Univ Oldenburg, European Med Sch Oldenburg Groningen, Klinikum Oldenburg, Dept Cardiol, Rahel Straus Str 10, D-26133 Oldenburg, Germany
[2] Univ Groningen, Univ Med Ctr Groningen, Ctr Med Imaging, Groningen, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Cardiol, Groningen, Netherlands
[4] Hosp Clin San Carlos, Dept Cardiol, Madrid, Spain
[5] Imperial Coll London, Hammersmith Hosp, London, England
关键词
Fractional flow reserve; FFR; Instantaneous wave-free ratio; iFR; Patient position; FRACTIONAL FLOW RESERVE; FREE RATIO IFR; CORONARY-ANGIOGRAPHY; BLOOD-FLOW; IMPACT; REVASCULARIZATION; VALIDATION; REGISTRY; HUMANS; VOLUME;
D O I
10.1007/s00392-017-1174-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background An influence of hydrostatic pressure on intracoronary indices of stenosis severity in vitro was recently reported. We sought to analyze the influence of hydrostatic pressure, caused by the height difference between the distal and proximal pressure sensor after guidewire positioning in the interrogated vessel, on intracoronary pressure measurements in vivo. Methods and results In 30 coronary stenoses, intracoronary pressure measurements were performed in supine, left, and right lateral patient position. Height differences between the distal and proximal pressure sensor were measured by blinded observers. Measurement results of the position with the highest ("high") and lowest height difference ("low") were compared. In group "high", all measured indices were higher: mean difference of fractional flow reserve (FFR) 0.045 (SD 0.033, 95% CI 0.033-0.057, p < 0.0001), of instantaneous wave-free ratio (iFR) 0.043 (SD 0.04, 95% CI 0.029-0.057, p < 0.0001), and of resting Pd/Pa 0.037 (SD 0.034, 95% CI 0.025-0.049, p < 0.0001). Addition of the physically expectable hydrostatic pressure to the distal coronary pressures of the control group abolished the differences: corrected Delta FFR -0.006 (SD 0.027, 95% CI -0.015 to 0.004, p = 0.26), corrected Delta Pd/Pa -0.008 (SD 0.03, 95% CI -0.019 to 0.003, p = 0.18). Adjustment for hydrostatic pressure of FFR values in a standard supine position increased all values in anterior vessels and decreased all values in posterior vessels. The mean changes of FFR due to adjustment were: LAD -0.048 (SD 0.016), CX 0.02 (SD 0.009), RCA 0.02 (SD 0.021). Dichotomous severity classification changed in 12.9% of stenoses. Conclusions The study demonstrates a relevant influence of hydrostatic pressure on intracoronary indices of stenosis severity in vivo, caused by the height differences between distal and proximal pressure sensor.
引用
收藏
页码:222 / 232
页数:11
相关论文
共 20 条
[1]   CORONARY FLOW RESERVE CALCULATED FROM PRESSURE MEASUREMENTS IN HUMANS - VALIDATION WITH POSITRON EMISSION TOMOGRAPHY [J].
DEBRUYNE, B ;
BAUDHUIN, T ;
MELIN, JA ;
PIJLS, NHJ ;
SYS, SU ;
BOL, A ;
PAULUS, WJ ;
HEYNDRICKX, GR ;
WIJNS, W .
CIRCULATION, 1994, 89 (03) :1013-1022
[2]  
Emerson R J, 1994, Am J Crit Care, V3, P289
[3]  
Härle T, 2017, HERZ, V42, P395, DOI 10.1007/s00059-016-4471-z
[4]   Effect of Coronary Anatomy and Hydrostatic Pressure on Intracoronary Indices of Stenosis Severity [J].
Haerle, Tobias ;
Luz, Mareike ;
Meyer, Sven ;
Kronberg, Kay ;
Nickau, Britta ;
Escaned, Javier ;
Davies, Justin ;
Elsaesser, Albrecht .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (08) :764-773
[5]   Real-world use of fractional flow reserve in Germany: results of the prospective ALKK coronary angiography and PCI registry [J].
Haerle, Tobias ;
Zeymer, Uwe ;
Hochadel, Matthias ;
Zahn, Ralf ;
Kerber, Sebastian ;
Zrenner, Bernhard ;
Schaechinger, Volker ;
Lauer, Bernward ;
Runde, Thorsten ;
Elsaesser, Albrecht .
CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (02) :140-150
[6]   Differences between automatically detected and steady-state fractional flow reserve [J].
Haerle, Tobias ;
Meyer, Sven ;
Vahldiek, Felix ;
Elsaesser, Albrecht .
CLINICAL RESEARCH IN CARDIOLOGY, 2016, 105 (02) :127-134
[7]   Comparison of instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) - First real world experience [J].
Haerle, Tobias ;
Bojara, Waldemar ;
Meyer, Sven ;
Elsaesser, Albrecht .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 199 :1-7
[8]   VOLUME AND DENSITY CHANGES OF BIOLOGICAL-FLUIDS WITH TEMPERATURE [J].
HINGHOFERSZALKAY, H .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 59 (06) :1686-1689
[9]   CONTINUOUS MONITORING OF BLOOD-VOLUME CHANGES IN HUMANS [J].
HINGHOFERSZALKAY, H ;
GREENLEAF, JE .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (03) :1003-1007
[10]   METHOD OF HIGH-PRECISION MICROSAMPLE BLOOD AND PLASMA MASS DENSITOMETRY [J].
HINGHOFERSZALKAY, H .