Recondensation performance of liquid helium cryostat for a 28 GHz electron cyclotron resonance ion source

被引:2
作者
Choi, Seyong [1 ]
Lee, Byoung-Seob [1 ]
Park, Jin Yong [1 ]
Ok, Jung-Woo [1 ]
Shin, Chang Seouk [1 ]
Yoon, Jang-Hee [1 ]
Won, Mi-Sook [1 ]
Kim, Byoung-Chul [2 ]
机构
[1] Korea Basic Sci Inst, Busan Ctr, Pusan 609735, South Korea
[2] Korea Res Inst Stand & Sci, Ctr Ionizing Radiat, Taejon 305340, South Korea
关键词
D O I
10.1063/1.4828710
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cryostat performance is essential for the stable operation of a superconducting magnet. A closed-cycle liquid helium cryostat was adopted for use for a superconducting electron cyclotron resonance (ECR) ion source by recondensing liquid helium vapor. The goal was to maintain the liquid helium filled reservoir at a constant level without transferring any liquid helium during the normal operation of the ECR ion source. To accomplish this, Gifford-McMahon (GM) refrigerators, which have two cold heads, were installed on the top of the cryostat. The cooling power of the GM cryocooler is 1.5W at the second stage and 50 W at the first stage. Each stage was connected to the liquid helium reservoir, a radiation shield including high-T-c current lead, and related items. Before commissioning the ECR ion source, a preliminary evaluation of the recondensation performance was carried out with the magnet in partial operation. The design of the cryostat, its fabrication, and the experimental results are reported. (C) 2013 AIP Publishing LLC.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Implementation of an operator intervention system for remote control of the RIKEN 28 GHz superconducting electron cyclotron resonance ion source
    Uchiyama, A.
    Furukawa, K.
    Higurashi, Y.
    Nakagawa, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02)
  • [42] Multiple charge ion beam generation with a 2.45 GHz electron cyclotron resonance ion source
    Yuan Xu
    ShiXiang Peng
    HaiTao Ren
    JiaMei Wen
    AiLin Zhang
    Tao Zhang
    JingFeng Zhang
    WenBin Wu
    ZhiYu Guo
    JiaEr Chen
    Science China(Physics,Mechanics & Astronomy), 2017, Mechanics & Astronomy)2017 (06) : 79 - 82
  • [43] Ion beam production with an antenna type 2.45 GHz electron cyclotron resonance ion source
    Liu, Y. G.
    Liu, J. L.
    Wu, Q.
    Sun, L. T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (02)
  • [44] Multiple charge ion beam generation with a 2.45 GHz electron cyclotron resonance ion source
    Yuan Xu
    ShiXiang Peng
    HaiTao Ren
    JiaMei Wen
    AiLin Zhang
    Tao Zhang
    JingFeng Zhang
    WenBin Wu
    ZhiYu Guo
    JiaEr Chen
    Science China Physics, Mechanics & Astronomy, 2017, 60
  • [45] Development of a 2.45 GHz electron cyclotron resonance ion source for ion-implanter application
    Sekiguchi, M.
    Matsushita, H.
    Jonoshita, I.
    Kabasawa, M.
    Review of Scientific Instruments, 1998, 69 (2 pt 2):
  • [46] Multiple charge ion beam generation with a 2.45 GHz electron cyclotron resonance ion source
    Xu, Yuan
    Peng, ShiXiang
    Ren, HaiTao
    Wen, JiaMei
    Zhang, AiLin
    Zhang, Tao
    Zhang, JingFeng
    Wu, WenBin
    Guo, ZhiYu
    Chen, JiaEr
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2017, 60 (06)
  • [47] Development of a 2.45 GHz electron cyclotron resonance ion source for ion-implanter application
    Sekiguchi, M
    Matsushita, H
    Jonoshita, I
    Kabasawa, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) : 837 - 839
  • [48] Experiments on a 14.5 GHz electron cyclotron resonance source
    Hill, CE
    Langbein, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02) : 643 - 645
  • [49] The effect of plasma electrode collar structure on the performance of the JYFL 14 GHz electron cyclotron resonance ion source
    Toivanen, V.
    Tarvainen, O.
    Komppula, J.
    Koivisto, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 726 : 41 - 46
  • [50] Electron cyclotron resonance ion source for ion thruster
    Satori, S
    Nishiyama, K
    Kuninaka, H
    Kuriki, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1996, 35 (1A): : 274 - 275