Effectivity of lead aprons to reduce the radiation dose of patient in CT.

被引:31
作者
Hidajat, N
Schroder, RJ
Vogl, T
Schedel, H
Felix, R
机构
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1996年 / 165卷 / 05期
关键词
dose reduction; radiation shield; computed tomography; thyroid gland; gonad;
D O I
10.1055/s-2007-1015790
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Investigation of the efficacy of lead apron, testis capsule and thyroid collar for dose reduction in uterus, ovaries, testes and thyroid gland in computed tomography examinations. Methods: At an Alderson-Rando-phantom dose of uterus, ovaries, testes and thyroid gland was measured with thermoluminescent dosemeters. CT of the upper abdomen, the whole abdomen and the skull were simulated without and with lead shielding. As lead shielding, a lead apron was attached around the pelvis of the phantom in case of CT of the upper abdomen, a testis capsule was used in CT of the whole abdomen and a thyroid collar in CT of the skull. Results: In CT of the upper abdomen the lead apron did not lead to any recognisable dose reduction in uterus and ovaries. In CT of the whole abdomen the testis capsule led to a dose reduction in testes of 95% (1.39 mSv) and in CT of the skull the thyroid collar to a dose reduction in thyroid gland of 23% (0.19 mSv). Conclusions: In abdominal CT examinations the testis capsule is an important instrument to reduce the dose of the testes whereas the lead apron is not appropriate for a dose reduction in the uterus and ovaries. In CT of the skull the thyroid collar can remarkably reduce the scattered radiation exposure of the thyroid gland and should be recommended.
引用
收藏
页码:462 / 465
页数:4
相关论文
共 9 条
[1]  
Drexler G, 1993, BESTIMMUNG ORGANDOSE
[2]  
FELSENBERG D, 1990, FORTSCHR RONTG NEUEN, V153, P516
[3]   REVIEW ARTICLE - RADIATION PROTECTION IN DENTAL RADIOLOGY [J].
HORNER, K .
BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (803) :1041-1049
[4]   RADIATION-DOSE REDUCTION IN CT OF THE PEDIATRIC PELVIS [J].
KAMEL, IR ;
HERNANDEZ, RJ ;
MARTIN, JE ;
SCHLESINGER, AE ;
NIKLASON, LT ;
GUIRE, KE .
RADIOLOGY, 1994, 190 (03) :683-687
[5]   RADIATION EXPOSURE DURING CT USING STANDARD AND SPIRAL TECHNIQUES [J].
LANGKOWSKI, JH ;
POGODA, P ;
HESS, A .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01) :3-11
[6]   GT OF THE CHEST - MINIMAL TUBE CURRENT REQUIRED FOR GOOD IMAGE QUALITY WITH THE LEAST RADIATION-DOSE [J].
MAYO, JR ;
HARTMAN, TE ;
LEE, KS ;
PRIMACK, SL ;
VEDAL, S ;
MULLER, NL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (03) :603-607
[7]  
REICH H, 1990, DOSIMETRIE STRAHLENS
[8]  
SEIFERT H, 1995, DTSCH ARTZEBL, V92, pA1769
[9]  
Stieve F E, 1981, Rontgenpraxis, V34, P87