Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology

被引:87
作者
Ruiz-Rodriguez, Juan C. [1 ,2 ,3 ,10 ]
Ruiz-Sanmartin, Adolf [1 ,2 ]
Ribas, Vicent [4 ]
Caballero, Jesus [1 ,2 ]
Garcia-Roche, Alejandra [1 ]
Riera, Jordi [1 ,3 ]
Nuvials, Xavier [5 ]
de Nadal, Miriam [3 ,6 ]
de Sola-Morales, Oriol [7 ]
Serra, Joaquim [1 ,2 ,3 ]
Rello, Jordi [1 ,3 ,8 ,9 ]
机构
[1] Vall dHebron Univ Hosp, Crit Care Dept, Barcelona, Spain
[2] Univ Autonoma Barcelona, Vall dHebron Res Inst VHIR, Shock Organ Dysfunct & Resuscitat SODIR Res Grp, E-08193 Barcelona, Spain
[3] Univ Autonoma Barcelona, Dept Med, E-08193 Barcelona, Spain
[4] Ctr Recerca Matemat, Barcelona, Spain
[5] Arnau de Vilanova Univ Hosp IRB, Crit Care Dept, Lleida, Spain
[6] Vall dHebron Univ Hosp, Dept Anaesthesiol, Barcelona, Spain
[7] Inst Invest Sanitaria Pere Virgili, Tarragona, Spain
[8] Univ Autonoma Barcelona, Vall dHebron Res Inst VHIR, E-08193 Barcelona, Spain
[9] CIBERES, Barcelona, Spain
[10] Hosp Univ Vall dHebron, Serv Med Intens, Area Gen, Barcelona 08035, Spain
关键词
Non-invasive hemodynamic monitoring; Blood pressure; Photoplethysmography; Critical care; Machine learning; ACCURACY; DEVICE;
D O I
10.1007/s00134-013-2964-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
To develop and validate a continuous non-invasive blood pressure (BP) monitoring system using photoplethysmography (PPG) technology through pulse oximetry (PO). This prospective study was conducted at a critical care department and post-anesthesia care unit of a university teaching hospital. Inclusion criteria were critically ill adult patients undergoing invasive BP measurement with an arterial catheter and PO monitoring. Exclusion criteria were arrhythmia, imminent death condition, and disturbances in the arterial or the PPG curve morphology. Arterial BP and finger PO waves were recorded simultaneously for 30 min. Systolic arterial pressure (SAP), mean arterial pressure (MAP), and diastolic arterial pressure (DAP) were extracted from computer-assisted arterial pulse wave analysis. Inherent traits of both waves were used to construct a regression model with a Deep Belief Network-Restricted Boltzmann Machine (DBN-RBM) from a training cohort of patients and in order to infer BP values from the PO wave. Bland-Altman analysis was performed. A total of 707 patients were enrolled, of whom 135 were excluded. Of the 572 studied, 525 were assigned to the training cohort (TC) and 47 to the validation cohort (VC). After data processing, 53,708 frames were obtained from the TC and 7,715 frames from the VC. The mean prediction biases were -2.98 +/- A 19.35, -3.38 +/- A 10.35, and -3.65 +/- A 8.69 mmHg for SAP, MAP, and DAP respectively. BP can be inferred from PPG using DBN-RBM modeling techniques. The results obtained with this technology are promising, but its intrinsic variability and its wide limits of agreement do not allow clinical application at this time.
引用
收藏
页码:1618 / 1625
页数:8
相关论文
共 25 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   THE OPTICS OF HUMAN-SKIN [J].
ANDERSON, RR ;
PARRISH, JA .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (01) :13-19
[3]   A new noninvasive method to measure blood pressure - Results of a multicenter trial [J].
Belani, K ;
Ozaki, M ;
Hynson, J ;
Hartmann, T ;
Reyford, H ;
Martino, JM ;
Poliac, M ;
Miller, R .
ANESTHESIOLOGY, 1999, 91 (03) :686-692
[4]   Accuracy of radial artery blood pressure determination with the Vasotrac™ [J].
Belani, KG ;
Buckley, JJ ;
Poliac, MO .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (05) :488-496
[5]   Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients [J].
Bur, A ;
Hirschl, MM ;
Herkner, H ;
Oschatz, E ;
Kofler, J ;
Woisetschläger, C ;
Laggner, AN .
CRITICAL CARE MEDICINE, 2000, 28 (02) :371-376
[6]   Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry [J].
Dueck, Ron ;
Goedje, Oliver ;
Clopton, Paul .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (02) :75-83
[7]   Vasotrac® arterial blood pressure and direct arterial blood pressure monitoring during liver transplantation [J].
Findlay, JY ;
Gali, B ;
Keegan, MT ;
Burkle, CM ;
Plevak, DJ .
ANESTHESIA AND ANALGESIA, 2006, 102 (03) :690-693
[8]   Reducing the dimensionality of data with neural networks [J].
Hinton, G. E. ;
Salakhutdinov, R. R. .
SCIENCE, 2006, 313 (5786) :504-507
[9]   A fast learning algorithm for deep belief nets [J].
Hinton, Geoffrey E. ;
Osindero, Simon ;
Teh, Yee-Whye .
NEURAL COMPUTATION, 2006, 18 (07) :1527-1554
[10]   An accuracy evaluation of the T-Line® Tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patients [J].
Janelle, GM ;
Gravenstein, N .
ANESTHESIA AND ANALGESIA, 2006, 102 (02) :484-490