Improving the performance of Ground Coupled Heat Exchangers in unsaturated soils

被引:30
|
作者
Platts, Arnold B. [1 ]
Cameron, Don A. [1 ]
Ward, James [1 ]
机构
[1] Univ S Australia, Barbara Hardy Inst, Adelaide, SA 5001, Australia
关键词
Dry soils; Ground wave; Passive cooling; Soil thermal conductivity; ANSYS; 14.5-CFX; THERMAL-CONDUCTIVITY;
D O I
10.1016/j.enbuild.2015.04.050
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ground heat exchangers (GHE) have serious limitations imposed upon them when installed in soils having low thermal conductivity and diffusivity. The restrictions to heat flow are: pipe surface area, the formation low thermal diffusivity and unsaturated soils moisture migration due to elevated temperatures. A comparative theoretical analysis has been conducted to ascertain the feasibility of a 'Membrane Conduction Augmentation System' (MCAS) to improve performance relative to a conventional Horizontal Ground Coupled Heat Exchanger (HGCHE). Results show that significant reductions in HGCHE length for equivalent cooling could be obtained in analyses both cyclic (simulating intermittent air-conditioning usage) and 10 day constant heat transfer stress test. Most significantly, the lower the soil's thermal conductivity and diffusivity the higher the efficiency of the proposed system. The MCAS simulated in the same size trench (300 mm) as that of a conventionally constructed 'direct burial' HGCHE yielded efficiency 46% higher for the 10 day stress test, while the 1200 mm MCAS improved by 150%. Both simulations used soil thermal conductivity of 0.54 W/m.K. Reductions in interface soil temperatures for the MCAS corresponded inversely to the size of the MCAS. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:323 / 335
页数:13
相关论文
共 50 条
  • [41] Performance of heat pumps with direct expansion in vertical ground heat exchangers in heating mode
    De Carli, Michele
    Fiorenzato, Stefano
    Zarrella, Angelo
    ENERGY CONVERSION AND MANAGEMENT, 2015, 95 : 120 - 130
  • [42] Artificial neural networks for predicting the performance of heat pumps with horizontal ground heat exchangers
    Zhou, Yu
    Narsilio, Guillermo
    Makasis, Nikolas
    Soga, Kenichi
    Chen, Peng
    Aye, Lu
    FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [43] Experimental study on the thermal performance of tunnel lining ground heat exchangers
    Zhang, Guozhu
    Xia, Caichu
    Yang, Yong
    Sun, Meng
    Zou, Yichuan
    ENERGY AND BUILDINGS, 2014, 77 : 149 - 157
  • [44] Transient heat transfer simulation, sensitivity analysis, and design optimization of shallow ground heat exchangers with hollow-finned structures for enhanced performance of ground-coupled heat pumps
    Al-Kbodi, Basher Hassan
    Rajeh, Taha
    Zayed, Mohamed E.
    Li, Yang
    Zhao, Jun
    Wu, Jiahui
    Liu, Yuanyuan
    ENERGY AND BUILDINGS, 2024, 305 (305)
  • [46] Revised heat transfer modeling of double-U vertical ground-coupled heat exchangers
    Conti, P.
    Testi, D.
    Grassi, W.
    APPLIED THERMAL ENGINEERING, 2016, 106 : 1257 - 1267
  • [47] An in situ thermal response test for borehole heat exchangers of the ground-coupled heat pump system
    Yang, Weibo
    Chen, Zhenqian
    Shi, Mingheng
    Zhang, Chengbin
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2013, 32 (05) : 489 - 503
  • [48] Compact heat exchangers: Improving heat recovery
    Alfa Laval Lund AB, Sweden
    不详
    Chem. Eng., 2009, 2 (44-47):
  • [49] Study on the coupled heat-water-vapor-mechanics process of unsaturated soils
    Bai, Ruiqiang
    Lai, Yuanming
    Zhang, Mingyi
    Ren, Jingge
    JOURNAL OF HYDROLOGY, 2020, 585
  • [50] Study on the coupled heat-water-vapor-mechanics process of unsaturated soils
    Bai, Ruiqiang
    Lai, Yuanming
    Zhang, Mingyi
    Ren, Jingge
    Journal of Hydrology, 2020, 585