Comparison of multivariate calibration and discriminant analysis in evaluating NIR spectroscopy for determination of meat tenderness

被引:21
|
作者
Naes, T
Hildrum, KI
机构
[1] Matforsk, N-1432 Ås
关键词
multivariate calibration; PCR; classification; discriminant analysis; meat tenderness; NIR; near-infrared;
D O I
10.1366/0003702971940198
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Often the primary goal of analytical measurement tasks is not to find good estimates of continuous reference values but rather to determine whether a sample belongs to one of a number of categories or subgroups. In this paper the potential of different statistical techniques in the classification of raw beef samples in tenderness subgroups was studied. The reference values were based on sensory analysis of beef tenderness of 90 samples from bovine M. longissimus dorsi muscles. The sample set was divided into three categories--very tough, intermediate, and very tender--according to degree of tenderness. A training set of samples was used to find the relationship between category and near-infrared (NIR) spectroscopic measurements. The study indicates that classical discriminant analysis has advantages in comparison to multivariate calibration methods [i.e., principal component repression (PCR)], in this application. One reason for this observation seems to be that PCR underestimates high measurement values and overestimates Low values. In this way most samples are assigned to the intermediate group of samples, causing a small number of erroneous classifications for the intermediate subgroup, but a large number of errors for the two extreme groups. With the use of PCR the number of correct classifications in the extreme subgroups was as love as 23%, while the use of discriminate analysis increased this number to almost 60%. The number of classifications in correct or neighbor subgroup for the two extreme subgroups was equal to 97%. A ''bias-correction'' was also attempted for PCR, and this gave results comparable to the best results obtained by discriminant analysis methods. Test sets used NTR analysis of fresh, raw beef samples with different processing. While this spectroscopic approach had previously been shown to be useful with frozen products, it appears unsuitable at this time for fresh beef. However, its marginal analytical utility proved useful in evaluating the two classification approaches employed in this study.
引用
收藏
页码:350 / 357
页数:8
相关论文
共 50 条
  • [11] Determination of amylose content in starch using Raman spectroscopy and multivariate calibration analysis
    Mariana R. Almeida
    Rafael S. Alves
    Laura B. L. R. Nascimbem
    Rodrigo Stephani
    Ronei J. Poppi
    Luiz Fernando C. de Oliveira
    Analytical and Bioanalytical Chemistry, 2010, 397 : 2693 - 2701
  • [12] Comparison of multivariate calibration techniques applied to experimental NIR data sets
    Centner, V
    Verdú-Andrés, J
    Walczak, B
    Jouan-Rimbaud, D
    Despagne, F
    Pasti, L
    Poppi, R
    Massart, DL
    de Noord, OE
    APPLIED SPECTROSCOPY, 2000, 54 (04) : 608 - 623
  • [13] Fluorescence Spectroscopy as a Tool for Determination of Coumarins by Multivariate Calibration
    Roman Poláček
    Pavel Májek
    Katarína Hroboňová
    Jana Sádecká
    Journal of Fluorescence, 2015, 25 : 297 - 303
  • [14] Fluorescence Spectroscopy as a Tool for Determination of Coumarins by Multivariate Calibration
    Polacek, Roman
    Majek, Pavel
    Hrobonova, Katarina
    Sadecka, Jana
    JOURNAL OF FLUORESCENCE, 2015, 25 (02) : 297 - 303
  • [15] Multivariate calibration models using NIR spectroscopy on pulp and paper industrial applications
    Antti, H
    Sjostrom, M
    Wallbacks, L
    JOURNAL OF CHEMOMETRICS, 1996, 10 (5-6) : 591 - 603
  • [16] Multivariate calibration models using NIR spectroscopy on pulp and paper industrial applications
    Antti, Henrik
    Sjöström, Michael
    Wallbäcks, Lars
    Journal of Chemometrics, 10 (5-6): : 591 - 603
  • [17] Determination of polymer blends composed of polycarbonate and rubber entities using near-infrared (NIR) spectroscopy and multivariate calibration
    Sulub, Yusuf
    DeRudder, James
    POLYMER TESTING, 2013, 32 (04) : 802 - 809
  • [18] Determination of sucrose in date fruits (Phoenix dactylifera L.) growing in the Sultanate of Oman by NIR spectroscopy and multivariate calibration
    Mabood, Fazal
    Al-Harrasi, Ahmed
    Bogue, Ricard
    Jabeen, Farah
    Hussain, Javid
    Hafidh, A.
    Hind, K.
    Ahmed, M. A. G.
    Manzoor, A.
    Hussain, Hidayat
    Rehman, Najeeb Ur
    Iman, S. H.
    Said, Jahina J.
    Hamood, Sara A.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 150 : 170 - 174
  • [19] NIR fiber-optic method with multivariate calibration analysis for determination of inorganic compounds in aqueous solutions
    Han, L
    Lucas, D
    Littlejohn, D
    Kyauk, S
    APPLIED SPECTROSCOPY, 2000, 54 (10) : 1447 - 1452
  • [20] Combining portable NIR spectroscopy and multivariate calibration for the determination of ethanol in fermented alcoholic beverages by a multi-product model
    da Costa Fulgencio, Ana Carolina
    Passos Resende, Glaucimar Alex
    Fontoura Teixeira, Marden Claret
    Botelho, Bruno Goncalves
    Sena, Marcelo Martins
    TALANTA OPEN, 2023, 7