A Method of Three-Dimensional Recording of Mandibular Movement Based on Two-Dimensional Image Feature Extraction

被引:14
作者
Yuan, Fusong [1 ,2 ,3 ,4 ]
Sui, Huaxin [1 ,2 ,3 ,4 ]
Li, Zhongke [5 ]
Yang, Huifang [1 ,2 ,3 ,4 ]
Lu, Peijun [1 ,2 ,3 ,4 ]
Wang, Yong [1 ,2 ,3 ,4 ]
Sun, Yuchun [1 ,2 ,3 ,4 ]
机构
[1] Peking Univ Sch & Hosp Stomatol, Ctr Digital Dent, Beijing, Peoples R China
[2] Peking Univ Sch & Hosp Stomatol, Fac Prosthodont, Beijing, Peoples R China
[3] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[4] Minist Hlth, Res Ctr Engn & Technol Digital Dent, Beijing, Peoples R China
[5] Second Artillery Engn Coll, Xian, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 09期
基金
中国国家自然科学基金;
关键词
D O I
10.1371/journal.pone.0137507
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and Objective To develop a real-time recording system based on computer binocular vision and two-dimensional image feature extraction to accurately record mandibular movement in three dimensions. Methods A computer-based binocular vision device with two digital cameras was used in conjunction with a fixed head retention bracket to track occlusal movement. Software was developed for extracting target spatial coordinates in real time based on two-dimensional image feature recognition. A plaster model of a subject's upper and lower dentition were made using conventional methods. A mandibular occlusal splint was made on the plaster model, and then the occlusal surface was removed. Temporal denture base resin was used to make a 3-cm handle extending outside the mouth connecting the anterior labial surface of the occlusal splint with a detection target with intersecting lines designed for spatial coordinate extraction. The subject's head was firmly fixed in place, and the occlusal splint was fully seated on the mandibular dentition. The subject was then asked to make various mouth movements while the mandibular movement target locus point set was recorded. Comparisons between the coordinate values and the actual values of the 30 intersections on the detection target were then analyzed using paired t-tests. Results The three-dimensional trajectory curve shapes of the mandibular movements were consistent with the respective subject movements. Mean XYZ coordinate values and paired t-test results were as follows: X axis: -0.0037 +/- 0.02953, P = 0.502; Y axis: 0.0037 +/- 0.05242, P = 0.704; and Z axis: 0.0007 +/- 0.06040, P = 0.952. The t-test result showed that the coordinate values of the 30 cross points were considered statistically no significant. (P<0.05) Conclusions Use of a real-time recording system of three-dimensional mandibular movement based on computer binocular vision and two-dimensional image feature recognition technology produced a recording accuracy of approximately +/- 0.1 mm, and is therefore suitable for clinical application. Certainly, further research is necessary to confirm the clinical applications of the method.
引用
收藏
页数:8
相关论文
共 13 条
  • [1] An in vitro evaluation of the reliability and validity of an electronic pantograph by testing with five different articulators
    Chang, WSW
    Romberg, E
    Driscoll, CF
    Tabacco, MJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (01) : 83 - 89
  • [2] Modeling of temporomandibular joint function using MRI and jaw-tracking technologies - Mechanics
    Gallo, LM
    [J]. CELLS TISSUES ORGANS, 2005, 180 (01) : 54 - 68
  • [3] FUNCTIONAL MOVEMENTS OF MANDIBLE
    GIBBS, CH
    MESSERMAN, T
    RESWICK, JB
    DERDA, HJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1971, 26 (06) : 604 - +
  • [4] Hanssen N, 2014, INT J COMPUT DENT, V17, P65
  • [5] Kordass Bernd, 2002, Dent Clin North Am, V46, P493, DOI 10.1016/S0011-8532(02)00006-X
  • [6] A MEANS FOR STUDYING MANDIBULAR MOVEMENTS
    MESSERMAN, T
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1967, 17 (01) : 36 - +
  • [7] Missaka Reinaldo, 2008, Braz. oral res., V22, P151, DOI 10.1590/S1806-83242008000200010
  • [8] Denture mobility with six degrees of freedom during function
    Miyashita, K
    Sekita, T
    Minakuchi, S
    Hirano, Y
    Kobayashi, K
    Nagao, M
    [J]. JOURNAL OF ORAL REHABILITATION, 1998, 25 (07) : 545 - 552
  • [9] Local kinematic and anthropometric factors related to the maximum mouth opening in healthy individuals
    Naeije, M
    [J]. JOURNAL OF ORAL REHABILITATION, 2002, 29 (06) : 534 - 539
  • [10] COMPUTERIZED AXIOGRAPHY - PRINCIPLES AND METHODS
    PIEHSLINGER, E
    CELAR, AG
    CELAR, RM
    SLAVICEK, R
    [J]. CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 1991, 9 (04): : 344 - 355