Primary failure of cardiac resynchronization therapy: what are the causes and is it worth considering a second attempt? A single-centre experience

被引:18
作者
Fatemi, Marjaneh [1 ]
Etienne, Yves [1 ]
Castellant, Philippe [1 ]
Blanc, Jean-Jacques [1 ]
机构
[1] CHU Cavale Blanche, Brest Univ Hosp, Dept Cardiol, F-29609 Brest, France
来源
EUROPACE | 2008年 / 10卷 / 11期
关键词
Heart failure; Cardiac resynchronization therapy; Technical success;
D O I
10.1093/europace/eun245
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Cardiac resynchronization therapy (CRT) has been validated as an effective treatment for patients with drug-refractory congestive heart failure and left bundle branch block. Failure of implantation of the left ventricular (LV) lead has been reported in 10-15% of patients. The goal of our study was to determine the causes of failure and the success rate following a repeat procedure by the same operators. Methods and results We reviewed our last 100 consecutive cases of CRT before July 2007. The procedure was considered as unsuccessful if it had to be interrupted before the placement of the LV lead in an appropriate position, because of patient's haemodynamic status or if the procedure duration exceeded 3 h. Cardiac resynchronization therapy was unsuccessful in 10 patients (5 men, mean age: 72 +/- 11 years). The causes of failure of CRT were as follows: no target vein other than the great cardiac vein (n = 5), coronary sinus dissection (n = 1), and a lateral vein too small to provide a stable location for the LV lead (n = 4). A second procedure was attempted in four patients and was successful in all cases. Conclusion In our study results, failure of CRT was observed in 10% of the patients. A second procedure can be attempted in a selected group of patients and is associated with a high success rate.
引用
收藏
页码:1308 / 1312
页数:5
相关论文
共 12 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]   Doppler myocardial Imaging to evaluate the effectiveness of pacing sites in patients receiving biventricular pacing [J].
Ansalone, G ;
Giannantoni, P ;
Ricci, R ;
Trambaiolo, P ;
Fedele, F ;
Santini, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) :489-499
[3]   A method for permanent transvenous left ventricular pacing [J].
Blanc, JJ ;
Benditt, DG ;
Gilard, M ;
Etienne, Y ;
Mansourati, J ;
Lurie, KG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2021-2024
[4]   Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. [J].
Cazeau, S ;
Leclercq, C ;
Lavergne, T ;
Walker, S ;
Varma, C ;
Linde, C ;
Garrigue, S ;
Kappenberger, L ;
Haywood, GA ;
Santini, M ;
Bailleul, C ;
Daubert, JC .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (12) :873-880
[5]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[6]   Permanent left ventricular pacing with transvenous leads inserted into the coronary veins [J].
Daubert, JC ;
Ritter, P ;
Le Breton, H ;
Gras, D ;
LeClercq, C ;
Lazarus, A ;
Mugica, J ;
Mabo, P ;
Cazeau, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01) :239-245
[7]   Evaluation of the coronary venous system using electron beam computed tomography [J].
Gerber, TC ;
Sheedy, PF ;
Bell, MR ;
Hayes, DL ;
Rumberger, JA ;
Behrenbeck, T ;
Holmes, DR ;
Schwartz, RS .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2001, 17 (01) :65-75
[8]   Angiographic anatomy of the coronary sinus and its tributaries [J].
Gilard, M ;
Mansourati, J ;
Etienne, Y ;
Larlet, JM ;
Truong, B ;
Boschat, J ;
Blanc, JJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2280-2284
[9]   Implantation of cardiac resynchronization therapy systems in the CARE-HF trial:: procedural success rate and safety [J].
Gras, D. ;
Boecker, D. ;
Lunati, M. ;
Wellens, H. J. J. ;
Calvert, M. ;
Freemantle, N. ;
Gervais, R. ;
Kappenberger, L. ;
Tavazzi, L. ;
Erdmann, E. ;
Cleland, J. G. F. ;
Daubert, J.-C. .
EUROPACE, 2007, 9 (07) :516-522
[10]   Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883