Prospective self-gating for simultaneous compensation of cardiac and respiratory motion

被引:69
作者
Buehrer, Martin
Curcic, Jelena
Boesiger, Peter
Kozerke, Sebastian
机构
[1] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[2] Swiss Fed Inst Technol, Zurich, Switzerland
关键词
cardiac imaging; self-gating; prospective motion compensation; respiratory motion; real-time filtering; cardiac motion;
D O I
10.1002/mrm.21697
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Segmented cardiac acquisitions generally require the use of an electrocardiogram (ECG) in combination with a breathhold or a respiratory navigator placed on the diaphragm. These techniques necessitate patient cooperation and increase the complexity of cardiac imaging. The ECG signal may be distorted inside the magnet by interferences from radiofrequency and gradient action. Breathhold acquisition limits the total scan time, while navigators on the diaphragm might not fully reflect respiratory-induced motion of the heart. To overcome some of these problems, several self-gating (SG) or "wireless" techniques have recently been presented. All of these approaches, however, are based on either cardiac triggering or respiratory gating, or the data are processed retrospectively, reducing the efficiency of data acquisition. In this work a prospective SG approach for free-breathing imaging is presented that requires neither ECG gating nor respiratory navigation. The motion data used for cardiac triggering and respiratory gating are extracted from the repeatedly acquired k-space center. Based on computer simulations and in vivo data of the heart, it is shown that cardiac as well as respiratory motion can be accurately extracted in real time. Using the method proposed, the scan efficiency could be significantly increased while preserving image quality relative to retrospective SG approaches.
引用
收藏
页码:683 / 690
页数:8
相关论文
共 27 条
[1]  
BUEHRER M, 2006, P 23 ANN M ESMRMB WA
[2]   Automated rectilinear self-gated cardiac cine imaging [J].
Crowe, ME ;
Larson, AC ;
Zhang, Q ;
Carr, J ;
White, RD ;
Li, DB ;
Simonetti, OP .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :782-788
[3]   RF INTERFERENCE SUPPRESSION IN A CARDIAC SYNCHRONIZATION SYSTEM OPERATING IN A HIGH MAGNETIC-FIELD NMR IMAGING-SYSTEM [J].
DAMJI, AA ;
SNYDER, RE ;
ELLINGER, DC ;
WITKOWSKI, FX ;
ALLEN, PS .
MAGNETIC RESONANCE IMAGING, 1988, 6 (06) :637-640
[4]  
Fischer SE, 1999, MAGN RESON MED, V42, P361, DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO
[5]  
2-9
[6]   Comparison between prospective and retrospective triggering for mouse cardiac MRI [J].
Heijman, Edwin ;
de Graaf, Wolter ;
Niessen, Petra ;
Nauerth, Arno ;
van Eys, Guillaume ;
de Graaf, Larry ;
Nicolay, Klaas ;
Strijkers, Gustav J. .
NMR IN BIOMEDICINE, 2007, 20 (04) :439-447
[7]   Cardiac and respiratory double self-gated cine MRI in the mouse at 7 T [J].
Hiba, B ;
Richard, N ;
Janier, M ;
Croisille, P .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :506-513
[8]   Cardiac and respiratory self-gated cine MRI in the mouse: Comparison between radial and rectilinear techniques at 7T [J].
Hiba, Bassem ;
Richard, Nathalie ;
Thibault, Helene ;
Janier, Marc .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (04) :745-753
[9]  
HOFMAN MBM, 1995, J COMPUT ASSIST TOMO, V19, P56
[10]   Motion artifact reduction and vessel enhancement for free-breathing navigator-gated coronary MRA using 3D k-space reordering [J].
Huber, ME ;
Hengesbach, D ;
Botnar, RM ;
Kissinger, KV ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :645-652