共 50 条
Colorimetric and chemiluminescent dual-readout immunochromatographic assay for detection of pesticide residues utilizing g-C3N4/BiFeO3 nanocomposites
被引:130
作者:
Ouyang, Hui
[1
,2
]
Tu, Xinman
[1
,3
]
Fu, Zhifeng
[2
]
Wang, Wenwen
[2
]
Fu, Shaofang
[1
]
Zhu, Chengzhou
[1
]
Du, Dan
[1
]
Lin, Yuehe
[1
]
机构:
[1] Washington State Univ, Sch Mech & Mat Engn, Pullman, WA 99164 USA
[2] Southwest Univ, Coll Pharmaceut Sci, Key Lab Luminescence & Real Time Analyt Chem, Minist Educ, Chongqing 400716, Peoples R China
[3] Nanchang Hangkong Univ, Key Lab Jiangxi Prov Persistent Pollutants Contro, Coll Environm & Chem Engn, Nanchang 330063, Jiangxi, Peoples R China
关键词:
Graphitic carbon nitride/bismuth ferrite nanocomposites;
Dual-readout;
Immunochromatographic assay;
Pesticide residues;
Chemiluminescence;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
GRAPHITIC CARBON NITRIDE;
TANDEM MASS-SPECTROMETRY;
ORGANOPHOSPHORUS PESTICIDES;
VISIBLE-LIGHT;
PHOTOCATALYTIC ACTIVITIES;
CARBAMATE PESTICIDES;
CATALYTIC-ACTIVITY;
GLUCOSE DETECTION;
RAPID DETECTION;
D O I:
10.1016/j.bios.2018.01.033
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
Graphitic carbon nitride/bismuth ferrite nanocomposites (g-C3N4/BiFeO3 NCs) were synthesized by a facile one step sol-gel combustion method and employed as a peroxidase-like catalyst. Based on the catalytical activity on the luminol-H2O2 reaction, the nanocomposites were utilized as a colorimetric/chemiluminescent dual-readout immunochromatographic assay (ICA) for the multiplexed detection of pesticide residues by utilizing chlorpyrifos and carbaryl as the model analytes. In the proposed protocol, chlorpyrifos antibody and carbaryl antibody were tagged to g-C3N4/BiFeO3 NCs for developing the spatially-resolved multianalyte ICA. After two competitive immunoreactions completed on the ICA test strip, the tracer antibodies were captured by the immobilized antigens on two test lines. The accumulation of g-C3N4/BiFeO3 NCs led to the appearance of brown color, which were observed as a colorimetric and semi-quantitative signal. Furthermore, the g-C3N4/BiFeO3 NCs-driven generation of CL signal was collected as a sensitively quantitative signal after initiating the luminol-H2O2 reaction on the test lines. Under the optimal conditions, the limits of detection of chlorpyrifos and carbaryl were both 0.033 ng/mL. The dual-readout ICA was successfully used to detect chlorpyrifos and carbaryl spiked in environmental water and traditional Chinese medicine samples with acceptable recovery values of 80-119% and 90-118%. Due to many advantages including low cost, time efficiency, high sensitivity and good portability, the novel ICA showed great potential in many areas such as drug safety, environmental monitoring and clinical diagnosis.
引用
收藏
页码:43 / 49
页数:7
相关论文