Delocalized recombination kinetic modelling of the LiF : Mg,Ti glow peak 5 thermoluminescence system

被引:11
作者
Weiss, D. [2 ]
Horowitz, Y. S. [3 ]
Oster, L. [1 ]
机构
[1] Sami Shamoon Coll Engn, Phys Unit, Beer Sheva, Israel
[2] Nucl Res Ctr Negev, IL-84190 Beer Sheva, Israel
[3] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
关键词
D O I
10.1088/0022-3727/41/18/185411
中图分类号
O59 [应用物理学];
学科分类号
摘要
TL kinetic theory based on delocalized recombination mechanisms is successful in predicting many characteristics of TL mechanisms when these are considered singly. However, the greater challenge of predicting a set of measured TL characteristics while using the same, or very nearly the same, parameter values has yet to be adequately addressed. In this work we apply delocalized kinetic modelling to describe four experimentally measured characteristics of the TL behaviour of peak 5 in LiF : Mg, Ti (TLD-100). These include: (i) optical absorption linear/exponentially saturating dose response of the appropriate OA bands with the experimentally measured dose filling constants; (ii) linear/supralinear TL dose response with f (D)(max) = 4-6 at a dose level of similar to 400-600 Gy; (iii) constancy of T-max with dose; (iv) agreement with the experimentally measured behaviour of T-max and f (D)(max) with heating rate. We are successful in describing most of the details of these characteristics; however, we have failed to find parameter values which also correctly describe the dose response behaviour at low dose levels (preceding the linear, then the supralinear region) and the behaviour of f (D)(max) with heating rate. It is suggested that kinetic modelling based on a mixture of localized and delocalized recombination could successfully describe all the characteristics involved.
引用
收藏
页数:9
相关论文
共 41 条
[1]   Modelling the dose response of peaks 4, 5 and 5b, in TLD-100, as a function of recombination temperature [J].
Biderman, S. ;
Oster, L. ;
Horowitz, Y. S. .
RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) :285-288
[2]   EFFECTS OF COOLING AND HEATING RATE ON TRAPPING PARAMETERS IN LIF-MG,TL CRYSTALS [J].
BOS, AJJ ;
VIJVERBERG, RNM ;
PITERS, TM ;
MCKEEVER, SWS .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1992, 25 (08) :1249-1257
[3]  
BOS AJJ, 1990, RADIAT PROT DOSIM, V33, P7
[4]   Dose response of the individual peak for LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (GR-200A) TL materials at the photon energies of 30, 104, 1250 keV [J].
Cai, GG ;
Bestion, N ;
Wang, SS ;
Shen, WX ;
Delard, R ;
Volpiliere, J ;
Fesquet, J ;
Gasiot, J .
RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) :213-215
[5]   Interpretation of very high activation energies and frequency factors in TL as being due to competition between centres [J].
Chen, R ;
HagYahya, A .
RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) :17-20
[6]   A new look at the models of the superlinear dose dependence of thermoluminescence [J].
Chen, R ;
Fogel, G ;
Lee, CK .
RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) :63-68
[7]  
CHEN R, 1984, THERMOLUMINESCENCE T, pCH2
[8]  
Chen R., 1981, ANAL THERMALLY STIMU
[9]   Fast cooling and computerised glow curve deconvolution in routine personnel monitoring with TLD-100 [J].
Figel, M ;
Sprunck, M .
RADIATION PROTECTION DOSIMETRY, 1999, 81 (04) :259-264
[10]   The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P [J].
Horowitz, Y ;
Olko, P .
RADIATION PROTECTION DOSIMETRY, 2004, 109 (04) :331-348