Traceability Issue in PM2.5 and PM10 Measurements

被引:42
作者
Aggarwal, S. G. [1 ]
Kumar, S. [1 ]
Mandal, P. [2 ]
Sarangi, B. [1 ]
Singh, K. [1 ]
Pokhariyal, J. [1 ]
Mishra, S. K. [1 ]
Agarwal, S. [2 ]
Sinha, D. [3 ]
Singh, S. [1 ]
Sharma, C. [1 ]
Gupta, P. K. [1 ]
机构
[1] CSIR Natl Phys Lab, New Delhi 110012, India
[2] CSIR Natl Environm Engn Res Inst, Zonal Lab, New Delhi 110028, India
[3] Govt Nagarjun Post Grad Sci Coll, Raipur 492010, Madhya Pradesh, India
来源
MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA | 2013年 / 28卷 / 03期
关键词
PM measurements; Mass and size; Traceability; NAAQS; Gas and aerosol metrology; POROUS-METAL DENUDER; COLLECTION EFFICIENCY; AEROSOL-PARTICLES; SAMPLERS; MASS; CLOSURE; DESIGN; GASES;
D O I
10.1007/s12647-013-0073-x
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Nowadays particle size and mass concentration measurements are the important parameter of the ambient air quality standards of several countries. The regulatory limits of mass concentration of particulate matter (PM) for the size classes of PM2.5 and PM10, i.e., particle sizes of less than or equal to 2.5 and 10 mu m in aerodynamic diameter, respectively in air are defined on yearly and hourly time-weighted-average basis. However, these limits are different in different regulations of the countries. Both of the parameters relate with the human health, climate and other issues, therefore accurate and precise measurement of these parameters are very important. Despite this, so far not much work has progressed in national metrology institutes (NMIs) worldwide on calibration and traceability issue of PM measurements. In this paper in context of PM measurement traceability, we present systematically the (1) air quality regulation in different countries, (2) reference methods for size and mass measurements, (3) variation/error and limitations of PM measurements based on the current results in this study and previously published results, (4) current status of PM size and mass calibration facility, (5) expected uncertainty in PM measurements, (6) add-on uncertainty in other parameters of national ambient air quality standards due to PM measurements, (7) where does traceability of PM issue stand against other parameters of air quality standards and its impact on health and climate, (8) NMIs working on this issue, (9) status at Bureau International des Poids et Mesures (BIPM), France and (10) conclusion. The aim of this paper is to better understand the importance of international system of units (SI) traceability issue in PM measurements, so wherever and whenever it is measured, should be acceptable everywhere, and data should be comparable for improving air quality and thus the quality of life. Funding agencies should be aware of this issue, and accept the results from the principle investigators and team only when their results have the traceability link to SI. NMIs should make program to involve industries in gas and aerosol metrology work to fulfill the requirement of calibration and standards. The regulatory authorities/ministry should work together with NMIs to improve the data quality of ambient measurements. This will greatly help to better make the policies and decisions on the related impacts. These were also the ultimate goals of "one-day pre-AdMet workshop" organized at National Physical Laboratory, New Delhi, India on February 20th, 2013.
引用
收藏
页码:153 / 166
页数:14
相关论文
共 40 条
[11]   Evaporation loss of ammonium nitrate particles during filter sampling [J].
Cheng, YH ;
Tsai, CJ .
JOURNAL OF AEROSOL SCIENCE, 1997, 28 (08) :1553-1567
[12]   A critical evaluation of interlaboratory data on total, elemental, and isotopic carbon in the carbonaceous particle reference material, NIST SRM 1649a [J].
Currie, LA ;
Benner, BA ;
Kessler, JD ;
Klinedinst, DB ;
Klouda, GA ;
Marolf, JV ;
Slater, JF ;
Wise, SA ;
Cachier, H ;
Cary, R ;
Chow, JC ;
Watson, J ;
Druffel, ERM ;
Masiello, CA ;
Eglinton, TI ;
Pearson, A ;
Reddy, CM ;
Gustafsson, Ö ;
Quinn, JG ;
Hartmann, PC ;
Hedges, JI ;
Prentice, KM ;
Kirchstetter, TW ;
Novakov, T ;
Puxbaum, H ;
Schmid, H .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2002, 107 (03) :279-298
[13]   Size matters more than chemistry for cloud-nucleating ability of aerosol particles [J].
Dusek, U. ;
Frank, G. P. ;
Hildebrandt, L. ;
Curtius, J. ;
Schneider, J. ;
Walter, S. ;
Chand, D. ;
Drewnick, F. ;
Hings, S. ;
Jung, D. ;
Borrmann, S. ;
Andreae, M. O. .
SCIENCE, 2006, 312 (5778) :1375-1378
[14]  
Eatough DJ, 2001, AEROSOL SCI TECH, V34, P1
[15]  
European Standard, 1998, EN12341 EUR STAND
[16]  
European Standard, 2005, 14907 EN EUR STAND
[17]  
European Standard, 2005, EN14902 EUR STAND
[18]   Development and Performance Evaluation of Air Sampler with Inertial Filter for Nanoparticle Sampling [J].
Furuuchi, Masami ;
Eryu, Kazunobu ;
Nagura, Mizuki ;
Hata, Mitsuhiko ;
Kato, Takaharu ;
Tajima, Naoko ;
Sekiguchi, Kazuhiko ;
Ehara, Kensei ;
Seto, Takafumi ;
Otani, Yoshio .
AEROSOL AND AIR QUALITY RESEARCH, 2010, 10 (02) :185-192
[19]   Interlaboratory comparison exercise for the determination of As, Cd, Ni and Pb in PM10 in Europe [J].
Gerboles, M. ;
Buzica, D. ;
Brown, R. J. C. ;
Yardley, R. E. ;
Hanus-Illnar, A. ;
Salfinger, M. ;
Vallant, B. ;
Adriaenssens, E. ;
Claeys, N. ;
Roekens, E. ;
Sega, K. ;
Jurasovic, J. ;
Rychlik, S. ;
Rabinak, E. ;
Tanet, G. ;
Passarella, R. ;
Pedroni, V. ;
Karlsson, V. ;
Alleman, L. ;
Pfeffer, U. ;
Gladtke, D. ;
Olschewski, A. ;
O'Leary, B. ;
O'Dwyer, M. ;
Pockeviciute, D. ;
Biel-Cwikowska, J. ;
Tursic, J. .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (20) :3488-3499
[20]  
Gupta P.K., 2012, MSI NEWSL METROL SOC, V2, P2