Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis

被引:21
作者
Kim, Kun-Soo [1 ]
Han, Oneil [2 ]
Gombosuren, Munkhtulga [2 ]
Kim, Sang-Hyo [2 ]
机构
[1] Korea Atom Energy Res Inst, Struct & Seism Safety Res Team, Daedeok Daero 989-111, Daejeon 34057, South Korea
[2] Yonsei Univ, Sch Civil & Environm Engn, Yonsei Ro 50, Seoul 03722, South Korea
关键词
Y-type perfobond rib shear connection; shear behavior; finite element analysis; numerical simulation; HYSTERETIC PERFORMANCE; COMPOSITE BEAMS; BEHAVIOR; RESISTANCE; MODEL; DUCTILITY; CAPACITY;
D O I
10.12989/scs.2019.31.1.053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study presents finite element analysis (FEA) on a Y-type perfobond rib shear connection using Abaqus software. The performance of a shear connection is evaluated by conducting a push-out test. However, in practice, it is inefficient to verify the performance by conducting a push-out test with regard to all design variables pertaining to a shear connector. To overcome this problem, FEA is conducted on various shear connectors to accurately estimate the shear strength of the Y-type perfobond rib shear connection. Previous push-out test results for 14 typical push-out test specimens and those obtained through FEA are compared to analyze the shear behavior including consideration of the design variables. The results show that the developed finite element model successfully reflects the effects of changes in the design variables. In addition, using the developed FEA model, the shear resistance of a stubby Y-type perfobond rib shear connector is evaluated based on the concrete strength and transverse rebar size variables. Then, the existing shear resistance formula is upgraded based on the FEA results.
引用
收藏
页码:53 / 67
页数:15
相关论文
共 39 条
[1]  
ACI Committee, 1999, 318M99 ACI
[2]  
Al-Darzi S. Y. K., 2007, American Journal of Applied Sciences, V4, P122, DOI 10.3844/ajassp.2007.122.127
[3]  
[Anonymous], AB DOC VERS 6 12
[4]  
[Anonymous], 2004, 1992122004A12019 EN
[5]  
CEN, 2004, EN199411
[6]   Shear behaviour of composite dowels in transversely cracked concrete [J].
Classen, Martin ;
Herbrand, Martin .
STRUCTURAL CONCRETE, 2015, 16 (02) :195-206
[7]   Effect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear Connectors [J].
Dai, X. H. ;
Lam, D. ;
Saveri, E. .
JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (11)
[8]  
Hechler O, 2011, COMPOS CONSTR STEEL, VVI, P78
[9]   Numerical analysis of tilted angle shear connectors in steel-concrete composite systems [J].
Khorramian, Koosha ;
Maleki, Shervin ;
Shariati, Mahdi ;
Jalali, Abdolrahim ;
Tahir, M. M. .
STEEL AND COMPOSITE STRUCTURES, 2017, 23 (01) :67-85
[10]   Hysteretic performance of stubby Y-type perfobond rib shear connectors depending on transverse rebar [J].
Kim, Kun-Soo ;
Han, Oneil ;
Choi, Jonghee ;
Kim, Sang-Hyo .
CONSTRUCTION AND BUILDING MATERIALS, 2019, 200 :64-79