Results at a minimum of 10 years of follow-up for AMS and PerFix HA-coated cementless total hip arthroplasty: impact of cross-linked polyethylene on implant longevity

被引:65
作者
Nakashima, Yasuharu [1 ]
Sato, Taishi [1 ]
Yamamoto, Takuaki [1 ]
Motomura, Goro [1 ]
Ohishi, Masanobu [1 ]
Hamai, Satoshi [1 ]
Akiyama, Mio [1 ]
Hirata, Masanobu [1 ]
Hara, Daisuke [1 ]
Iwamoto, Yukihide [1 ]
机构
[1] Kyushu Univ, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
基金
日本学术振兴会;
关键词
MOLECULAR-WEIGHT POLYETHYLENE; ACETABULAR CUPS; YOUNG PATIENT; WEAR DEBRIS; FIXATION; OSTEOLYSIS;
D O I
10.1007/s00776-013-0456-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The purpose of this study was to report results at a minimum of 10 years for hydroxyapatite (HA) coating on the titanium arc-sprayed cementless total hip arthroplasty (THA) and to evaluate the impact of cross-linked polyethylene (XLPE) on implant longevity. Methods A total of 131 consecutive primary THAs in 123 patients using an AMS acetabular cup and a PerFix HA stem were retrospectively reviewed. Conventional PE was used for 62 hips (CPE group) and cross-linked PE for 69 hips (XLPE group), with mean follow-up periods of 13 and 11.5 years, respectively. These patients were reviewed using the Japanese Orthopaedic Association (JOA) Hip Score and evaluated in terms of PE wear, osteolysis, and implant survival. Results The JOA score improved from 42.6 to 83.9 points at the final follow-up. The mean wear rate of 0.12 mm/year in the CPE group was significantly greater than that of XLPE at 0.007 mm/year. In the CPE group, ten (16.1 %) and two (3.2 %) hips, respectively, underwent PE exchange due to severe wear and acetabular revision due to loosening associated with osteolysis. Three patients had revision in the XLPE group: one cup for aseptic loosening, one PE for recurrent dislocation, and one stem for neck fracture. No evident osteolysis was seen in the XLPE group. Kaplan-Meier survivorship with any revision as the end point shows that the 12-year survival rate was 97.7 % for cups, 93.8 % for PE liners, and 99.2 % for stems. Multivariate analysis revealed that the use of XLPE significantly reduced the risk of revision, with the odds ratio (OR) of 4.3. Conclusions AMS and PerFix HA components in this series show excellent implant fixation; however, high rates of PE wear and subsequent osteolysis were limiting factors in long-term success. Low wear rates with XLPE suggest improved implant longevity.
引用
收藏
页码:962 / 968
页数:7
相关论文
共 28 条
[11]  
ENGH CA, 1994, CLIN ORTHOP RELAT R, P89
[12]   Comparative Survival of Uncemented Acetabular Components Following Primary Total Hip Arthroplasty [J].
Howard, James L. ;
Kremers, Hilal Maradit ;
Loechler, Youlonda A. ;
Schleck, Cathy D. ;
Harmsen, William S. ;
Berry, Daniel J. ;
Cabanela, Miguel E. ;
Hanssen, Arlen D. ;
Pagnano, Mark W. ;
Trousdale, Robert T. ;
Lewallen, David G. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (17) :1597-1604
[13]  
Hozack WJ, 1996, CLIN ORTHOP RELAT R, P217
[14]   COMPARISON OF BONE-IMPLANT INTERFACE SHEAR-STRENGTH OF HYDROXYAPATITE-COATED AND ALUMINA-COATED METAL IMPLANTS [J].
INADOME, T ;
HAYASHI, K ;
NAKASHIMA, Y ;
TSUMURA, H ;
SUGIOKA, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01) :19-24
[15]   Outcome in patients lost to follow-up [J].
Joshi, AB ;
Gill, GS ;
Smith, PL .
JOURNAL OF ARTHROPLASTY, 2003, 18 (02) :149-153
[16]   Implant fixation by bone ingrowth [J].
Kienapfel, H ;
Sprey, C ;
Wilke, A ;
Griss, P .
JOURNAL OF ARTHROPLASTY, 1999, 14 (03) :355-368
[17]   Reliability and validity of the Japanese Orthopaedic Association hip score [J].
Kuribayashi, Masaaki ;
Takahashi, Kenji A. ;
Fujioka, Mikihiro ;
Ueshima, Keiichiro ;
Inoue, Shigehiro ;
Kubo, Toshikazu .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2010, 15 (04) :452-458
[18]   History and Systematic Review of Wear and Osteolysis Outcomes for First-generation Highly Crosslinked Polyethylene [J].
Kurtz, Steven M. ;
Gawel, Heather A. ;
Patel, Jasmine D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) :2262-2277
[19]   Survivorship of 2000 Tapered Titanium Porous Plasma-sprayed Femoral Components [J].
Lombardi, Adolph V., Jr. ;
Berend, Keith R. ;
Mallory, Thomas H. ;
Skeels, Michael D. ;
Adams, Joanne B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) :146-154
[20]   Fixation of acetabular cups without cement in total hip arthroplasty - A comparison of three different implant surfaces at a minimum duration of follow-up of five years [J].
Manley, MT ;
Capello, WN ;
D'Antonio, JA ;
Edidin, AA ;
Geesink, RGT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (08) :1175-1185