Clinical Implications of a Quality Assessment of Transcutaneous CO2 Monitoring in Preterm Infants in Neonatal Intensive Care

被引:7
作者
Hejlesen, Ole K. [1 ]
Cichosz, Simon Lebech [1 ]
Vangsgaard, Steffen [1 ]
Andresen, Mikkel Frank [1 ]
Madsen, Lars Peter [2 ]
机构
[1] Aalborg Univ, Dept Hlth Sci & Technol, Fredrik Bajersvej 7 D1, DK-9220 Aalborg, Denmark
[2] Aalborg Hosp, Dept Pediat, Aalborg, Denmark
来源
MEDICAL INFORMATICS IN A UNITED AND HEALTHY EUROPE | 2009年 / 150卷
关键词
prematurity; neonatal care; CO2; monitoring; transcutaneous CO2;
D O I
10.3233/978-1-60750-044-5-490
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
More than 1% of infants are born premature. Many of these children require special treatment because of immature organs and body functions. CO2 is an important parameter to monitor in order to avoid serious brain damage. Blood sampling of CO2 has several shortcomings and non-invasive transcutaneous CO2 is being investigated in order to assess its potential to contribute with the same type of information as blood CO2 measurements. The present study assesses the quality of transcutaneous CO2 data by comparing it to the "golden standard" blood CO2 data, in order to provide clinicians with a better understanding of the usefulness and limitations of transcutaneous CO2 data in neonatal care. The study shows that for low transcutaneous CO2 the error is relatively high and in most cases the true CO2, represented by the blood CO2, which can be regarded as the "gold standard", is higher than the measured transcutaneous CO2. The opposite is the case for high transcutaneous CO2. It is discussed how this is not due to any systematic error in the equipment, but due to the natural behaviour of noisy data.
引用
收藏
页码:490 / 494
页数:5
相关论文
共 8 条
[1]  
[Anonymous], 2006, FODSL FODS
[2]   Periventricular leucomalacia: a review [J].
Blumenthal, I .
EUROPEAN JOURNAL OF PEDIATRICS, 2004, 163 (08) :435-442
[3]   Medical progress - Hypocapnia [J].
Laffey, JG ;
Kavanagh, BP .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (01) :43-53
[4]   Minimising neonatal brain injury: how research in the past five years has changed my clinical practice [J].
Levene, Malcolm .
ARCHIVES OF DISEASE IN CHILDHOOD, 2007, 92 (03) :261-265
[5]   Are carbon dioxide detectors useful in neonates? [J].
Molloy, E. J. ;
Deakins, K. .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2006, 91 (04) :F295-F298
[6]  
Polin R. A., 2004, FETAL NEONATAL PHYSL, V1
[7]  
RENNIE J, 2005, ROBERTSONS TXB NEONA
[8]   A survey of transcutaneous blood gas monitoring among European neonatal intensive care units [J].
Rüdiger M. ;
Töpfer K. ;
Hammer H. ;
Schmalisch G. ;
Wauer R.R. .
BMC Pediatrics, 5 (1)