Application of partial discharge testing to motor and generator stator winding maintenance

被引:54
|
作者
Stone, GC
Sedding, HG
Costello, MJ
机构
[1] ONTARIO HYDRO TECHNOL,TORONTO,ON M8Z 5S4,CANADA
[2] TEXACO USA INC,BELLAIRE,TX 77402
关键词
D O I
10.1109/28.491498
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Deterioration of stator winding insulation continues to be one of the predominant-causes of large motor and generator failures. Over the past several years, practical methods have been developed for measuring the partial discharge activity in the high voltage insulation of stator windings, since partial discharges are a symptom of most of the insulation failure mechanisms in motors and generators rated 4 kV or more. The turbine generator analyzer (TGA) test has now been specifically developed to enable industrial plant staff to reliably perform a partial discharge test on operating motors and turbine generators. This paper presents several case studies of the use of these new partial discharge test technologies on rotating machines. Test results show that machines with deteriorated windings have a Partial discharge activity al least 30 times higher than good windings. The availability of these test methods enables plant staff to economically and reliably plan stator winding maintenance, avoid unexpected failures and often extend the time between major maintenance outages.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 50 条
  • [1] Application of partial discharge testing to motor and generator stator winding maintenance
    Power Engineering Inc, Mississauga, Canada
    IEEE Trans Ind Appl, 2 (459-464):
  • [2] APPLICATION OF PARTIAL DISCHARGE TESTING TO HYDRO GENERATOR MAINTENANCE
    KURTZ, M
    LYLES, JF
    STONE, GC
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (08): : 2148 - 2157
  • [3] Analysis on the Ultrasonic Propagate for Partial Discharge in the Generator Stator Winding
    Yang, Yongming
    Jiang, Fan
    Zhang, Zulong
    Lin, Kunming
    ADVANCED MATERIALS AND COMPUTER SCIENCE, PTS 1-3, 2011, 474-476 : 1368 - 1372
  • [4] Analysis on the ultrasonic online location for partial discharge in the stator winding of generator
    Wang, Quan-Di
    Yang, Cheng-He
    Yang, Yong-Ming
    Zhang, Yu-Peng
    Lu, Jun-Jie
    Chongqing Daxue Xuebao/Journal of Chongqing University, 2009, 32 (10): : 1150 - 1153
  • [5] Facilitating Proactive Stator Winding Maintenance Using Partial Discharge Patterns
    Kuppuswamy, Raja
    Rainey, Sandy
    2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 566 - 571
  • [6] Experimental Study of Partial Discharge Pulses Propagation in Stator Winding of Hydro Generator
    Luo, Yuanlin
    Li, Zhaohui
    Chen, Tian
    PROCEEDINGS OF 2017 IEEE 2ND INFORMATION TECHNOLOGY, NETWORKING, ELECTRONIC AND AUTOMATION CONTROL CONFERENCE (ITNEC), 2017, : 773 - 777
  • [7] Diagnosis of stator winding insulation of large generator based on partial discharge measurement
    Yuo, Bo
    Chen, Xiaolin
    Cheng, Yonghong
    Song, Jiancheng
    Xie, Hengkun
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (02) : 387 - 395
  • [8] Application of UHF on partial discharge detection in generator stator bar
    Li, X
    Li, CR
    Wang, W
    Wan, WJ
    Shen, XJ
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2004, : 676 - 678
  • [9] Online Partial Discharge Measurements in an Operating Generator Stator Winding Using UHF Antennas
    Partyka, Mike
    Bridges, Greg E.
    Kordi, Behzad
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (03) : 1593 - 1602
  • [10] Using partial discharge measurement technology to implement predictive maintenance in high voltage motor and generator stator windings
    Stone, G
    Kapler, J
    1997 IEEE/PCA CEMENT INDUSTRY TECHNICAL CONFERENCE - XXXIX CONFERENCE RECORD, 1997, : 63 - 68