Lysis-Assisted Balloon (LAB) Thrombectomy. A Declotting Technique for the Treatment of Thrombosed Arteriovenous Dialysis Grafts. 5-Year Experience of 241 Endovascular Procedures

被引:11
作者
Kitrou, Panagiotis M. [1 ]
Papadimatos, Panagiotis [1 ]
Spiliopoulos, Stavros [2 ]
Christeas, Nicolaos [1 ]
Katsanos, Konstantinos [1 ]
Karnabatidis, Dimitris [1 ]
机构
[1] Patras Univ Hosp, Intervent Radiol Dept, Patras, Greece
[2] Attikon Univ Hosp, Intervent Radiol Div, Dept Radiol 2, Athens, Greece
关键词
Thrombolysis; Thrombectomy; Arteriovenous graft; AVG; Dialysis; rtPA; Stent graft; Thrombus; Angioplasty; RANDOMIZED CONTROLLED-TRIAL; PACLITAXEL-COATED BALLOONS; VASCULAR ACCESS; HEMODIALYSIS GRAFT; WAIT TECHNIQUE; SINGLE-CENTER; STENT-GRAFT; ANGIOPLASTY; FISTULAS; STENOSIS;
D O I
10.1007/s00270-017-1813-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This is a retrospective single-center analysis investigating the results of a percutaneous lysis-assisted balloon (LAB) thrombectomy procedure for the treatment of thrombosed arteriovenous dialysis grafts (AVGs). Within 5 years (January 2012-December 2016), 291 declotting procedures were performed for the treatment of thrombosed dialysis arteriovenous fistulas or grafts. Data were available for 129 patients (75 men, 58.1%) with an AVG, undergoing 241 procedures [1.87 procedures/patient (1-10)]. Procedure includes initial lysis with 5 mg recombinant tissue plasminogen activator followed by thrombectomy with a high-pressure balloon for thrombus maceration using "facing sheaths" technique. 61 patients had ae<yen> 2 declotting procedures. In 80 cases (80/241; 33.2%), a stent graft (SG) was used for treatment of persistent stenosis. Main primary outcome measures were clinical success and postintervention assisted primary patency (PAPP). Secondary outcome measures included procedural complications and investigation of independent factors that could influence circuit survival. Median PAPP was 434 days according to Kaplan-Meier survival analysis. Clinical success was 96.26%. In six cases (6/241, 2.49%) declotting failed and a catheter was placed. There were 16 minor (16/241, 6.64%) and no major complications. There was no significant difference in circuit survival regardless of SG use (No SG 406 days vs. SG 349 days; p = 0.24). There was a significant difference in favor of the second declotting compared to the first in 61 patients (first: 162 days vs. second: 447 days; p < 0.0001). LAB thrombectomy resulted in high-circuit survival rates with increased technical success and minimum complications without the use of thrombectomy devices.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 35 条
[1]   Randomized Clinical Trial of Cutting Balloon Angioplasty versus High-Pressure Balloon Angioplasty in Hemodialysis Arteriovenous Fistula Stenoses Resistant to Conventional Balloon Angioplasty [J].
Aftab, Syed Arafat ;
Tay, Kiang Hiong ;
Irani, Farah G. ;
Lo, Richard Hoau Gong ;
Gogna, Apoorva ;
Haaland, Benjamin ;
Tan, Seck Guan ;
Chng, Slew Png ;
Pasupathy, Shanker ;
Choong, Hui Lin ;
Tan, Bien Soo .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (02) :190-198
[2]   Endovascular Revascularization of Hemodialysis Thrombosed Grafts with the Hydrodynamic Thrombectomy Catheter. Our 7-Year Experience [J].
Bermudez, Patricia ;
Fontsere, Nestor ;
Mestres, Gaspar ;
Garcia-Gamez, Andres ;
Barrufet, Marta ;
Burrel, Marta ;
Gilabert, Rosa ;
Gomez, Fernando ;
Macho, Juan .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 40 (02) :252-259
[3]  
Bush Ruth L, 2004, Semin Vasc Surg, V17, P32, DOI 10.1053/j.semvascsurg.2003.11.005
[4]   Hemodialysis graft declotting: Description of the ''lyse and wait'' technique [J].
Cynamon, J ;
Lakritz, PS ;
Wahl, SI ;
Bakal, CW ;
Sprayregen, S .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1997, 8 (05) :825-829
[5]   Quality Improvement Guidelines for Percutaneous Image-Guided Management of the Thrombosed or Dysfunctional Dialysis Circuit [J].
Dariushnia, Sean R. ;
Walker, T. Gregory ;
Silberzweig, James E. ;
Annamalai, Ganesan ;
Krishnamurthy, Venkataramu ;
Mitchell, Jason W. ;
Swan, Timothy L. ;
Wojak, Joan C. ;
Nikolic, Boris ;
Midia, Mehran .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (10) :1518-1530
[6]   Aspirex Thrombectomy in Occluded Dialysis Access: A Retrospective Study [J].
Dyer, Jules ;
Rosa, Joao ;
Chachlani, Menka ;
Nicholas, Johann .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (10) :1484-1490
[7]  
FAN PY, 1992, J AM SOC NEPHROL, V3, P1
[8]  
Gibbens D T, 2001, Tech Vasc Interv Radiol, V4, P122, DOI 10.1053/tvir.2001.25446
[9]   Thromboaspiration of arteriovenous hemodialysis graft thrombosis using Desilets-Hoffman sheath: single-center experience [J].
Goo, Dong Erk ;
Kim, Yong Jae ;
Park, Sung Tae ;
Yang, Seung Boo ;
Yoon, Sang Chul ;
Song, Dan .
JOURNAL OF VASCULAR ACCESS, 2014, 15 (05) :401-408
[10]   Prospective, Randomized, Concurrently Controlled Study of a Stent Graft versus Balloon Angioplasty for Treatment of Arteriovenous Access Graft Stenosis: 2-Year Results of the RENOVA Study [J].
Haskal, Ziv J. ;
Saad, Theodore F. ;
Hoggard, Jeffery G. ;
Cooper, Randy I. ;
Lipkowitz, George S. ;
Gerges, Anwar ;
Ross, John R. ;
Pflederer, Timothy A. ;
Mietling, Samuel W. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (08) :1105-1114