Audible noise of transmission lines caused by the corona effect: Analysis, modelling, prediction

被引:20
作者
Engel, Z
Wszolek, T
机构
[1] Mechanics and Vibroacoustics Dept., Tech. Univ. of Mining and Metallurgy, 30-059 Cracow
关键词
transmission lines; corona effect; audible noise;
D O I
10.1016/0003-682X(95)00041-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The paper presents the results of investigations of audible noise of high voltage transmission lines of alternating current (a.c. UHV) caused by the corona effect. The investigation results concern the 400 kV lines in two basic layouts existing in Poland: single horizontal and double vertical. Environmental investigations in real conditions were executed in a whole year cycle with the short-term method. Apart from the results of the environmental investigations the paper contains also the laboratory investigation results. The influence of constructional design and environmental parameters on the sound level distribution along a span was analysed. The influence of the conductor surface stare and weather conditions on the level and shape of the emitted audible noise spectrum was particularly taken into account. The evaluation of the influence of the line audible noise on the acoustic climate of the environment was carried out. The analysis of possibilities of the application of well known computational procedures to the prediction of the line audible noise caused by the corona effect in Polish conditions was executed and an original form of a line acoustic model with the audible noise prediction possibility as a function of rainfall was presented. (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:149 / 163
页数:15
相关论文
共 45 条
  • [41] Analysis and Comparison of Audible Noise Caused by Magnetic Components in Switch-Mode Power Supplies Operating in Burst Mode and Frequency-Foldback Mode
    Huber, Laszlo
    Jovanovic, Milan M.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) : 5299 - 5308
  • [42] Assessing the impact of the Corona effect on the lightning response of transmission lines using the Time Domain Hybrid Electromagnetic Model (HEM-TD)
    Silva, Barbara Pereira
    Visacro, Silverio
    Silveira, Fernando H.
    Macedo, Sany
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 216
  • [43] Fault Analysis of The Distance Protection Overreach Caused by The Power Transmission Lines Ring Closing with A Wrong Phase Sequence
    He, He
    Wang, Hongbin
    Huang, Ruiling
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 114 - 118
  • [44] Modified field-to-line coupling model for simulating the corona effect on the lightning induced voltages of multi-conductor transmission lines over a lossy ground
    Liu, Xin
    Yang, Jiawei
    Liang, Guishu
    Wang, Litong
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (07) : 1865 - 1876
  • [45] Lightning Shielding Analysis of EHV and UHV AC Transmission Lines: the Effect of Operating Voltage and Terrain Topography
    Cuaran, Jose
    Acosta, Jbair
    Becerra, Marley
    Roman, Francisco
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1756 - 1760