Audible noise of transmission lines caused by the corona effect: Analysis, modelling, prediction

被引:20
作者
Engel, Z
Wszolek, T
机构
[1] Mechanics and Vibroacoustics Dept., Tech. Univ. of Mining and Metallurgy, 30-059 Cracow
关键词
transmission lines; corona effect; audible noise;
D O I
10.1016/0003-682X(95)00041-7
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The paper presents the results of investigations of audible noise of high voltage transmission lines of alternating current (a.c. UHV) caused by the corona effect. The investigation results concern the 400 kV lines in two basic layouts existing in Poland: single horizontal and double vertical. Environmental investigations in real conditions were executed in a whole year cycle with the short-term method. Apart from the results of the environmental investigations the paper contains also the laboratory investigation results. The influence of constructional design and environmental parameters on the sound level distribution along a span was analysed. The influence of the conductor surface stare and weather conditions on the level and shape of the emitted audible noise spectrum was particularly taken into account. The evaluation of the influence of the line audible noise on the acoustic climate of the environment was carried out. The analysis of possibilities of the application of well known computational procedures to the prediction of the line audible noise caused by the corona effect in Polish conditions was executed and an original form of a line acoustic model with the audible noise prediction possibility as a function of rainfall was presented. (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:149 / 163
页数:15
相关论文
共 45 条
  • [21] Generation Mechanism of Pure Tones of Audible Noise Caused by Single Corona Source Under AC Voltages
    Li X.
    Wang J.
    Cheng L.
    Lu T.
    Cui X.
    Xie H.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (03): : 906 - 914
  • [22] Simulation calculation and measurement analysis of audible noise for ±800 kV Yunnan-Guangdong UHVDC transmission lines
    Deng, J. (reacherempire@163.com), 1600, Science Press (38): : 3268 - 3276
  • [23] Calculation and Research of Audible Noise of AC Transmission Lines (Ⅱ) - Distribution Under Crossing Erection
    Fu W.
    He W.
    Xie G.
    Liang Q.
    Lan L.
    Chen Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (12): : 4070 - 4078
  • [24] Optimization method for multi-factor tests of audible noise on UHVDC transmission lines
    Zhao, Penghui
    Yuan, Haiwen
    Liu, Chengxin
    Zhou, Hu
    Xu, Hai
    Zhang, Xiangdong
    2022 IEEE 17TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2022, : 1673 - 1677
  • [25] Calculation and Research of Audible Noise of AC Transmission Lines (Ⅰ) - Three-dimensional Distribution
    Xie G.
    Fu W.
    He W.
    Lan L.
    Wan B.
    Zhang Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (09): : 2990 - 2998
  • [26] Simulation and Experimental Study on Corona Noise Distribution of UHV Transmission Lines
    Zhao, Guo
    Song, Haoran
    Zhu, Heping
    Li, Shulin
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2025, 18 (03) : 292 - 305
  • [27] Application of π Circuits for Simulation of Corona Effect in Transmission Lines
    Lessa, L. S.
    Prado, A. J.
    Bonelli, M. L.
    Kurokawa, S.
    Pissolato Filho, J.
    Bovolato, L. F.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [28] Invalid Data Rejection of Audible Noise on AC Transmission Lines Based on Moving Window Kernel Principal Component Analysis
    Cheng, Ziyi
    Li, Zhenhua
    Huang, Yuehua
    Yao, Weifang
    Xie, Huichun
    FRONTIERS IN ENERGY RESEARCH, 2021, 9
  • [29] Time-domain Correlation Between Audible Noise and Radio Interference Caused by Single Positive Corona Source on the Conductor
    Cheng L.
    Li X.
    Ma H.
    Li Y.
    Lu T.
    Liu Y.
    Gaodianya Jishu/High Voltage Engineering, 2019, 45 (12): : 4088 - 4095
  • [30] Effect of Rain Drops on Corona Discharge in Alternating Current Transmission Lines with a Corona Cage
    Chen, Lan
    Bian, Xingming
    Wang, Lingming
    Guan, Zhicheng
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2012, 51 (09)