Effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography

被引:15
|
作者
Parthasarathy, Mohana Kuppuswamy [1 ,2 ,3 ]
Bhende, Muna [1 ]
机构
[1] Med Res Fdn, Sri Bhagwan Mahavir Vitreoretinal Serv, Dept Vitreoretinal Serv, Madras, Tamil Nadu, India
[2] Elite Sch Optometry, Dept Vitreoretinal Serv, Madras, Tamil Nadu, India
[3] Birla Inst Technol & Sci, Dept Vitreoretinal Serv, Pilani, Rajasthan, India
关键词
Artifact; foveal diameter; foveal slope; ocular magnification; optical coherence tomography; NERVE-FIBER LAYER; FOVEAL PIT MORPHOLOGY; GEOGRAPHIC ATROPHY; THICKNESS; SIZE; PREDICTORS; CHILDREN; PROFILE; MYOPIA; SEX;
D O I
10.4103/0301-4738.159877
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: The aim of the present study was to study the effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography (OCT). Materials and Methods: One hundred and fifty-one subjects were included from the normative study of foveal morphology carried out at our hospital. Subjects underwent comprehensive eye examination and macular scanning using Cirrus high-definition OCT and axial length (AXL) measurement. Macular cube 512 x 128 scan protocol was used for scanning the macula. Automated measurements of the fovea namely foveal diameter, foveal slope (lateral measurements) and foveal depth (axial measurement) were taken. A correction factor for ocular magnification was done using the formula t = p x q x s, where "t" is the corrected measurement, "p" is the magnification of OCT, "q" is the ocular magnification, and "s" is the measurement on OCT without correction. The difference between corrected and uncorrected measurements was evaluated for statistical significance. Results: Mean AXL was 22.95 +/- 0.78 mm. Refractive error ranged from -3D to + 4D. Mean difference between measured and corrected foveal diameter, slope and depth was 166.05 +/- 95.37 mu m (P < 0.001), 0.81 degrees +/- 0.53 degrees (P < 0.001) and 0.05 +/- 0.49 mu m (P = 0.178) respectively. AXL lesser than the OCT calibrated value of 24.46 mm showed an increased foveal diameter (r = 0.961, P < 0.001) and a reduced foveal slope (r = -0.863, P < 0.001) than the corrected value. Conclusion: Lateral measurements made on OCT varied with AXL s other than the OCT calibrated value of 24.46 mm. Therefore, to estimate the actual dimensions of a retinal lesion using OCT, especially lateral dimensions, we recommend correction for the ocular magnification factor.
引用
收藏
页码:427 / 431
页数:5
相关论文
共 50 条
  • [41] Spectral domain macular optical coherence tomography: a new diagnostic tool for glaucoma?
    White, Andrew
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 (09) : 823 - 824
  • [42] Spectral domain optical coherence tomography evolutive features in acute macular neuroretinopathy
    Azar, Georges
    Wolff, Benjamin
    Cornut, Pierre-Loic
    Sahel, Jose-Alain
    Mauget-Faysse, Martine
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (05) : 850 - 852
  • [43] Spectral-Domain Optical Coherence Tomography Characteristics of Macular Contusion Trauma
    Yu, Weihong
    Zheng, Lin
    Zhang, Zhiqiao
    Dai, Rongping
    Dong, Fangtian
    OPHTHALMIC RESEARCH, 2012, 47 (04) : 220 - 224
  • [44] Optical coherence tomography in paediatric glaucoma: time domain versus spectral domain
    Ghasia, Fatema F.
    Freedman, Sharon F.
    Rajani, Anand
    Holgado, Sandra
    Asrani, Sanjay
    El-dairi, Mays
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (07) : 837 - 842
  • [45] Astigmatism and optical coherence tomography measurements
    Hwang, Young Hoon
    Lee, Sang Mok
    Kim, Yong Yeon
    Lee, Jong Yeon
    Yoo, Chungkwon
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (02) : 247 - 254
  • [46] The Application of Enhanced Depth Imaging Spectral-Domain Optical Coherence Tomography in Macular Diseases
    Wang, Jing
    Yin, Lian-Rong
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [47] Macular Findings Obtained by Spectral Domain Optical Coherence Tomography in Retinopathy of Prematurity
    Erol, Muhammet Kazim
    Ozdemir, Ozdemir
    Coban, Deniz Turgut
    Bilgin, Ahmet Burak
    Dogan, Berna
    Sari, Esin Sogutlu
    Toslak, Devrim
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [48] Retinal vessel diameter measurements by spectral domain optical coherence tomography
    Yanling Ouyang
    Qing Shao
    Dirk Scharf
    Antonia M. Joussen
    Florian M. Heussen
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2015, 253 : 499 - 509
  • [49] COMPARISON OF SPECTRAL/FOURIER DOMAIN OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS FOR ASSESSMENT OF NORMAL MACULAR THICKNESS
    Sull, Alan C.
    Vuong, Laurel N.
    Price, Lori Lyn
    Srinivasan, Vivek J.
    Gorczynska, Iwona
    Fujimoto, James G.
    Schuman, Joel S.
    Duker, Jay S.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (02): : 235 - 245
  • [50] Evaluation of spectral domain optical coherence tomography parameters in ocular hypertension, preperimetric, and early glaucoma
    Aydogan, Tugba
    Akcay, Betul Ilkay Sezgin
    Kardes, Esra
    Ergin, Ahmet
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (11) : 1143 - 1150