Effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography

被引:15
|
作者
Parthasarathy, Mohana Kuppuswamy [1 ,2 ,3 ]
Bhende, Muna [1 ]
机构
[1] Med Res Fdn, Sri Bhagwan Mahavir Vitreoretinal Serv, Dept Vitreoretinal Serv, Madras, Tamil Nadu, India
[2] Elite Sch Optometry, Dept Vitreoretinal Serv, Madras, Tamil Nadu, India
[3] Birla Inst Technol & Sci, Dept Vitreoretinal Serv, Pilani, Rajasthan, India
关键词
Artifact; foveal diameter; foveal slope; ocular magnification; optical coherence tomography; NERVE-FIBER LAYER; FOVEAL PIT MORPHOLOGY; GEOGRAPHIC ATROPHY; THICKNESS; SIZE; PREDICTORS; CHILDREN; PROFILE; MYOPIA; SEX;
D O I
10.4103/0301-4738.159877
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: The aim of the present study was to study the effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography (OCT). Materials and Methods: One hundred and fifty-one subjects were included from the normative study of foveal morphology carried out at our hospital. Subjects underwent comprehensive eye examination and macular scanning using Cirrus high-definition OCT and axial length (AXL) measurement. Macular cube 512 x 128 scan protocol was used for scanning the macula. Automated measurements of the fovea namely foveal diameter, foveal slope (lateral measurements) and foveal depth (axial measurement) were taken. A correction factor for ocular magnification was done using the formula t = p x q x s, where "t" is the corrected measurement, "p" is the magnification of OCT, "q" is the ocular magnification, and "s" is the measurement on OCT without correction. The difference between corrected and uncorrected measurements was evaluated for statistical significance. Results: Mean AXL was 22.95 +/- 0.78 mm. Refractive error ranged from -3D to + 4D. Mean difference between measured and corrected foveal diameter, slope and depth was 166.05 +/- 95.37 mu m (P < 0.001), 0.81 degrees +/- 0.53 degrees (P < 0.001) and 0.05 +/- 0.49 mu m (P = 0.178) respectively. AXL lesser than the OCT calibrated value of 24.46 mm showed an increased foveal diameter (r = 0.961, P < 0.001) and a reduced foveal slope (r = -0.863, P < 0.001) than the corrected value. Conclusion: Lateral measurements made on OCT varied with AXL s other than the OCT calibrated value of 24.46 mm. Therefore, to estimate the actual dimensions of a retinal lesion using OCT, especially lateral dimensions, we recommend correction for the ocular magnification factor.
引用
收藏
页码:427 / 431
页数:5
相关论文
共 50 条
  • [21] Precision and Agreement of Individual and Simultaneous Macular and Optic Disc Volumetric Measurements With Spectral Domain Optical Coherence Tomography
    Dominguez-Vicent, Alberto
    Kensen, Jesper
    Ramsay, Marika Wahlberg
    Brautaset, Rune
    Venkataraman, Abinaya Priya
    FRONTIERS IN MEDICINE, 2021, 8
  • [22] Characteristics of Hyperautofluorescent Choroidal Vessels within the Macular Atrophic Area Using Spectral-Domain Optical Coherence Tomography
    Shinojima, Ari
    Mori, Ryusaburo
    Nakashizuka, Hiroyuki
    Tanaka, Koji
    Fujita, Kyoko
    Kawamura, Akiyuki
    Haruyama, Miho
    Yamamoto, Atsushi
    Yuzawa, Mitsuko
    OPHTHALMOLOGICA, 2016, 235 (04) : 208 - 214
  • [23] Repeatability of Spectral Domain Optical Coherence Tomography Measurements in High Myopia
    Rao, Harsha L.
    Kumar, Addepalli U.
    Bonala, Sampath R.
    Yogesh, Kadam
    Lakshmi, Bodduluri
    JOURNAL OF GLAUCOMA, 2016, 25 (05) : E526 - E530
  • [24] Effects of Refractive Power on Macular Thickness Measurement Using Spectral-Domain Optical Coherence Tomography
    Lee, Sung Bok
    Shin, Il Hwan
    Shin, Kyung Sup
    Jo, Young Joon
    Kim, Jung Yeul
    OPHTHALMOLOGICA, 2015, 234 (03) : 172 - 176
  • [25] Macular edema in the era of spectral-domain optical coherence tomography
    Hunter, Allan
    Chin, Eric K.
    Telander, David G.
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 2085 - 2089
  • [26] Influence of Axial Length on Thickness Measurements Using Spectral-Domain Optical Coherence Tomography
    Roeck, Tobias
    Bartz-Schmidt, Karl Ulrich
    Bramkamp, Matthias
    Roeck, Daniel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7494 - 7498
  • [27] Assessment of the effect of age on macular layer thickness in a healthy Chinese cohort using spectral-domain optical coherence tomography
    Xu, Qian
    Li, Ying
    Cheng, Ying
    Qu, Yi
    BMC OPHTHALMOLOGY, 2018, 18
  • [28] Repeatability and Reproducibility of Macular Thickness Measurements Using Fourier Domain Optical Coherence Tomography
    Bruce, Alison
    Pacey, Ian E.
    Dharni, Poonam
    Scally, Andy J.
    Barrett, Brendan T.
    OPEN OPHTHALMOLOGY JOURNAL, 2009, 3 : 10 - 14
  • [29] Book review: spectral domain optical coherence tomography in macular diseases
    Müller Gonçalves Urias
    Eduardo Büchele Rodrigues
    International Journal of Retina and Vitreous, 3 (1)
  • [30] Parameters of ocular fundus on spectral-domain optical coherence tomography for glaucoma diagnosis
    Tao, Yu-Lin
    Tao, Li-Ming
    Jiang, Zheng-Xuan
    Liu, He-Ting
    Liang, Kun
    Li, Mo-Han
    Zhu, Xuan-Sheng
    Ren, Yan-Lin
    Cui, Bing-Jie
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (06) : 982 - 991