Effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography

被引:15
|
作者
Parthasarathy, Mohana Kuppuswamy [1 ,2 ,3 ]
Bhende, Muna [1 ]
机构
[1] Med Res Fdn, Sri Bhagwan Mahavir Vitreoretinal Serv, Dept Vitreoretinal Serv, Madras, Tamil Nadu, India
[2] Elite Sch Optometry, Dept Vitreoretinal Serv, Madras, Tamil Nadu, India
[3] Birla Inst Technol & Sci, Dept Vitreoretinal Serv, Pilani, Rajasthan, India
关键词
Artifact; foveal diameter; foveal slope; ocular magnification; optical coherence tomography; NERVE-FIBER LAYER; FOVEAL PIT MORPHOLOGY; GEOGRAPHIC ATROPHY; THICKNESS; SIZE; PREDICTORS; CHILDREN; PROFILE; MYOPIA; SEX;
D O I
10.4103/0301-4738.159877
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: The aim of the present study was to study the effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography (OCT). Materials and Methods: One hundred and fifty-one subjects were included from the normative study of foveal morphology carried out at our hospital. Subjects underwent comprehensive eye examination and macular scanning using Cirrus high-definition OCT and axial length (AXL) measurement. Macular cube 512 x 128 scan protocol was used for scanning the macula. Automated measurements of the fovea namely foveal diameter, foveal slope (lateral measurements) and foveal depth (axial measurement) were taken. A correction factor for ocular magnification was done using the formula t = p x q x s, where "t" is the corrected measurement, "p" is the magnification of OCT, "q" is the ocular magnification, and "s" is the measurement on OCT without correction. The difference between corrected and uncorrected measurements was evaluated for statistical significance. Results: Mean AXL was 22.95 +/- 0.78 mm. Refractive error ranged from -3D to + 4D. Mean difference between measured and corrected foveal diameter, slope and depth was 166.05 +/- 95.37 mu m (P < 0.001), 0.81 degrees +/- 0.53 degrees (P < 0.001) and 0.05 +/- 0.49 mu m (P = 0.178) respectively. AXL lesser than the OCT calibrated value of 24.46 mm showed an increased foveal diameter (r = 0.961, P < 0.001) and a reduced foveal slope (r = -0.863, P < 0.001) than the corrected value. Conclusion: Lateral measurements made on OCT varied with AXL s other than the OCT calibrated value of 24.46 mm. Therefore, to estimate the actual dimensions of a retinal lesion using OCT, especially lateral dimensions, we recommend correction for the ocular magnification factor.
引用
收藏
页码:427 / 431
页数:5
相关论文
共 50 条
  • [1] Effect of Ocular Magnification on Macular Choroidal Thickness Measurements Made Using Optical Coherence Tomography in Children
    Deng, Junjie
    Jin, Jiali
    Zhang, Bo
    Zhang, Siqi
    Wang, Jingjing
    Xiong, Shuyu
    Cheng, Tianyu
    Liu, Kun
    Huang, Jiannan
    He, Xiangui
    Xu, Xun
    CURRENT EYE RESEARCH, 2022, 47 (11) : 1538 - 1546
  • [2] Macular Measurements Using Spectral-Domain Optical Coherence Tomography in Chinese Myopic Children
    Chen, Si
    Wang, Bingsong
    Dong, Ning
    Ren, Xiaofang
    Zhang, Tuohong
    Xiao, Lin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (11) : 7410 - 7416
  • [3] The effects of ocular magnification on Spectralis spectral domain optical coherence tomography scan length
    Ctori, Irene
    Gruppetta, Stephen
    Huntjens, Byki
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (05) : 733 - 738
  • [4] The effects of ocular magnification on Spectralis spectral domain optical coherence tomography scan length
    Irene Ctori
    Stephen Gruppetta
    Byki Huntjens
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2015, 253 : 733 - 738
  • [5] Macular Imaging for Glaucoma Using Spectral-domain Optical Coherence Tomography: A Review
    Wong, Jessica J.
    Chen, Teresa C.
    Shen, Lucy Q.
    Pasquale, Louis R.
    SEMINARS IN OPHTHALMOLOGY, 2012, 27 (5-6) : 160 - 166
  • [6] Macular thickness and volume of myopic eyes measured using spectral-domain optical coherence tomography
    Hwang, Young Hoon
    Kim, Yong Yeon
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2012, 95 (05) : 492 - 498
  • [7] Effect of Spectral Domain Optical Coherence Tomography Image Quality on Macular Thickness Measurements and Error Rate
    Falavarjani, Khalil Ghasemi
    Mehrpuya, Amirabbas
    Amirkourjani, Foad
    CURRENT EYE RESEARCH, 2017, 42 (02) : 282 - 286
  • [8] Macular thickness and macular volume measurements using spectral domain optical coherence tomography in normal Nepalese eyes
    Pokharel, Amrit
    Shrestha, Gauri Shankar
    Shrestha, Jyoti Baba
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 511 - 519
  • [9] Macular spectral-domain optical coherence tomography values and correlations in healthy children
    Passani, Andrea
    Sframeli, Angela Tindara
    Posarelli, Chiara
    Lisi, Domenico
    Guidi, Gianluca
    Casini, Giamberto
    Ferreras, Antonio
    Figus, Michele
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2449 - 2457
  • [10] MACULAR AND PERIPAPILLARY SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY CHANGES IN SICKLE CELL RETINOPATHY
    Brasileiro, Fabiana
    Martins, Thayze T.
    Campos, Silvio B.
    Andrade, Joao L.
    Bravo-Filho, Vasco T.
    Araujo, Aderson S.
    Arantes, Tiago E.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (02): : 257 - 263