Gas exchange calculation may estimate changes in pulmonary blood flow during veno-arterial extracorporeal membrane oxygenation in a porcine model

被引:14
作者
Bachmann, Kaspar F. [1 ,2 ]
Haenggi, Matthias [2 ]
Jakob, Stephan M. [2 ]
Takala, Jukka [2 ]
Gattinoni, Luciano [3 ]
Berger, David [2 ]
机构
[1] Univ Bern, Bern Univ Hosp, Inselspital, Dept Anaesthesiol & Pain Med, Bern, Switzerland
[2] Univ Bern, Bern Univ Hosp, Inselspital, Dept Intens Care Med, Bern, Switzerland
[3] Univ Gottingen, Dept Anesthesiol Emergency & Intens Care Med, Gottingen, Germany
关键词
carbon dioxide; cardiac output; ECMO; intensive care; weaning; CARBON-DIOXIDE REMOVAL; ENERGY-EXPENDITURE; VENTILATION;
D O I
10.1152/ajplung.00167.2019
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Veno-arterial extracorporeal membrane oxygenation (V-A ECMO) is used as rescue therapy for severe cardiopulmonary failure. We tested whether the ratio of CO2 elimination at the lung and the V-A ECMO ((V) over dotCO(2ECMO)/(V) over dotCO(2Lung)) would reflect the ratio of respective blood flows and could be used to estimate changes in pulmonary blood flow ((Q) over dot(Lung)) i.e., native cardiac output. Four healthy pigs were centrally cannulated for V-A ECMO. We measured blood flows with an ultrasonic flow probe. (V) over dotCO(2ECMO) and (V) over dotCO(2Lung) were calculated from sidestream capnographs under constant pulmonary ventilation during V-A ECMO weaning with changing sweep gas and/or V-A ECMO blood flow. If ventilation-to-perfusion ratio ((V) over dot/(Q) over dot) of V-A ECMO was not 1, the (V) over dotCO(2ECMO) was normalized to (V) over dot/(Q) over dot = 1 ((V) over dotCO(2ECMONorm)). Changes in pulmonary blood flow were calculated using the relationship between changes in CO2 elimination and V-A ECMO blood flow ((Q) over dot(ECMO)). (Q) over dot(ECMO) correlated strongly with (V) over dotCO(2ECMONorm) (r(2) 0.95-0.99). (Q) over dot(Lung) correlated well with (V) over dotCO(2Lung) (r(2) 0.65-0.89, P < = 0.002). Absolute (Q) over dot(Lung) could not be calculated in a nonsteady state. Calculated pulmonary blood flow changes had a bias of 76 (-266 to 418) mL/min and correlated with measured (Q) over dot(Lung) (r(2) 0.974-1.000, P = 0.1 to 0.006) for cumulative ECMO flow reductions. In conclusion, (V) over dotCO(2) of the lung correlated strongly with pulmonary blood flow. Our model could predict pulmonary blood flow changes within clinically acceptable margins of error. The prediction is made possible with normalization to a (V) over dot/(Q) over dot of 1 for ECMO. This approach depends on measurements readily available and may allow immediate assessment of the cardiac output response.
引用
收藏
页码:L1211 / L1221
页数:11
相关论文
共 23 条
[1]   Weaning of extracorporeal membrane oxygenation using continuous hemodynamic transesophageal echocardiography [J].
Cavarocchi, Nicholas C. ;
Pitcher, Harrison T. ;
Yang, Qiong ;
Karbowski, Pawel ;
Miessau, Joseph ;
Hastings, Harold M. ;
Hirose, Hitoshi .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 146 (06) :1474-1479
[2]   The ICM research agenda on extracorporeal life support [J].
Combes, Alain ;
Brodie, Dan ;
Chen, Yih-Sharng ;
Fan, Eddy ;
Henriques, Jose P. S. ;
Hodgson, Carol ;
Lepper, Philipp M. ;
Leprince, Pascal ;
Maekawa, Kunihiko ;
Muller, Thomas ;
Nuding, Sebastian ;
Ouweneel, Dagmar M. ;
Roch, Antoine ;
Schmidt, Matthieu ;
Takayama, Hiroo ;
Vuylsteke, Alain ;
Werdan, Karl ;
Papazian, Laurent .
INTENSIVE CARE MEDICINE, 2017, 43 (09) :1306-1318
[3]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[4]   Measuring resting energy expenditure during extracorporeal membrane oxygenation: preliminary clinical experience with a proposed theoretical model [J].
De Waele, E. ;
van Zwam, K. ;
Mattens, S. ;
Staessens, K. ;
Diltoer, M. ;
Honore, P. M. ;
Czapla, J. ;
Nijs, J. ;
La Meir, M. ;
Huyghens, L. ;
Spapen, H. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2015, 59 (10) :1296-1302
[5]   Extracorporeal CO2 Removal: The Minimally Invasive Approach, Theory, and Practice [J].
Duscio, Eleonora ;
Cipulli, Francesco ;
Vasques, Francesco ;
Collino, Francesca ;
Rapetti, Francesca ;
Romitti, Federica ;
Behnemann, Tim ;
Niewenhuys, Julia ;
Tonetti, Tommaso ;
Pasticci, Iacopo ;
Vassalli, Francesco ;
Reupke, Verena ;
Moerer, Onnen ;
Quintel, Michael ;
Gattinoni, Luciano .
CRITICAL CARE MEDICINE, 2019, 47 (01) :33-40
[6]  
HANNON JP, 1990, LAB ANIM SCI, V40, P293
[7]   Volumetric Capnography for Noninvasive Monitoring of Acute Respiratory Distress Syndrome [J].
Jonson, Bjorn .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 198 (03) :396-398
[8]  
Keener JJ, 2009, MATH PHYSL SYSTEMS P, V2nd, P694
[9]   Factors Predicting Early- and Long-Term Survival in Patients Undergoing Extracorporeal Membrane Oxygenation (ECMO) [J].
Lee, Seung Hyun ;
Chung, Cheol Hyun ;
Lee, Jae Won ;
Jung, Sung Ho ;
Choo, Suk Jung .
JOURNAL OF CARDIAC SURGERY, 2012, 27 (02) :255-263
[10]   Efficiency of gas transfer in venovenous extracorporeal membrane oxygenation: analysis of 317 cases with four different ECMO systems [J].
Lehle, Karla ;
Philipp, Alois ;
Hiller, Karl-Anton ;
Zeman, Florian ;
Buchwald, Dirk ;
Schmid, Christof ;
Dornia, Christian ;
Lunz, Dirk ;
Mueller, Thomas ;
Lubnow, Matthias .
INTENSIVE CARE MEDICINE, 2014, 40 (12) :1870-1877