Evaluating Contrast Agent Waste and Costs of Weight-Based CT Contrast Bolus Protocols Using Single-or Multiple-Dose Packaging

被引:14
作者
Robinson, Jeffrey D. [1 ]
Mitsumori, Lee M. [1 ]
Linnau, Ken F. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98104 USA
关键词
contrast agent injector; control software; cost containment; CT; economics; ABDOMINAL CT; HEPATIC ENHANCEMENT; BODY-WEIGHT; REDUCTION; VOLUME;
D O I
10.2214/AJR.12.9479
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Although weight-based contrast agent injection protocols can improve contrast-enhanced CT, one disadvantage is waste caused by differences between the amount of contrast material required for a weight-based algorithm and full-package protocols used with single-use packaging of contrast material. The availability of 500-mL multiple-use packaging of contrast material should facilitate the implementation of weight-based contrast bolus protocols for CT because arbitrary volumes of contrast agent can be loaded without significant waste. Our hypothesis was that multiple-use packaging when used with a weight-based contrast bolus protocol would reduce costs compared with single-use packaging. MATERIALS AND METHODS. Contrast agent volume loaded and volume actually delivered to 1304 patients undergoing abdominal and pelvic CT were recorded. Model 1 used volume loaded to estimate contrast material cost, model 2 used volume delivered, and model 3 assumed that patients received either 100 or 150 mL from a single-use package, depending on weight. RESULTS. Model 1 required 368 packages of 500 mL contrast material ($ 23,000). Model 2 required 353 packages of 500 mL contrast material ($ 22,062.50). Model 3 required 863 and 478 packages of 100 and 150 mL contrast material, respectively ($ 22,120). CONCLUSION. Cost containment can be realized while improving the quality of contrast opacification by employing 500-mL multiple-use packaging of contrast materials. Care must be taken by the technologists to load only the volume of contrast agent that is needed, or the resulting contrast agent waste will negate the savings and even result in cost increases.
引用
收藏
页码:W617 / W620
页数:4
相关论文
共 10 条
  • [1] Cost reduction in abdominal CT by weight-adjusted dose
    Arana, Estanislao
    Marti-Bonmati, Luis
    Tobarra, Eva
    Sierra, Consuelo
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (03) : 507 - 511
  • [2] Optimization of Contrast Enhancement in Thoracic MDCT
    Bae, Kyongtae T.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2010, 48 (01) : 9 - +
  • [3] Optimal Vascular and Parenchymal Contrast Enhancement: The Current State of the Art
    Fleischmann, Dominik
    Kamaya, Aya
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) : 13 - +
  • [4] DYNAMIC INCREMENTAL CT - EFFECT OF VOLUME AND CONCENTRATION OF CONTRAST MATERIAL AND PATIENT WEIGHT ON HEPATIC ENHANCEMENT
    HEIKEN, JP
    BRINK, JA
    MCCLENNAN, BL
    SAGEL, SS
    CROWE, TM
    GAINES, MV
    [J]. RADIOLOGY, 1995, 195 (02) : 353 - 357
  • [5] Body Size Indexes for Optimizing Iodine Dose for Aortic and Hepatic Enhancement at Multidetector CT: Comparison of Total Body Weight, Lean Body Weight, and Blood Volume
    Kondo, Hiroshi
    Kanematsu, Masayuki
    Goshima, Satoshi
    Tomita, Yuhei
    Kim, Myeong-Jin
    Moriyama, Noriyuki
    Onozuka, Minoru
    Shiratori, Yoshimune
    Bae, Kyongtae T.
    [J]. RADIOLOGY, 2010, 254 (01) : 163 - 169
  • [6] DYNAMIC CONTRAST ENHANCEMENT OF THE UPPER ABDOMEN - EFFECT OF CONTRAST-MEDIUM AND BODY-WEIGHT
    KORMANO, M
    PARTANEN, K
    SOIMAKALLIO, S
    KIVIMAKI, T
    [J]. INVESTIGATIVE RADIOLOGY, 1983, 18 (04) : 364 - 367
  • [7] Aortic enhancement during abdominal CT angiography: Correlation with test injections, flow rates, and patient demographics
    Platt, JF
    Reige, KA
    Ellis, JH
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (01) : 53 - 56
  • [8] Robinson TJ, 2012, J DIGIT IMAGING
  • [9] Contrast and Cost Savings by Implementation of a Multidose Bulk IV Contrast Delivery System
    Routhier, Justin
    Piazzo, Kathy
    Sodickson, Aaron
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2011, 8 (04) : 265 - 270
  • [10] Usefulness of saline pushing in reduction of contrast material dose in abdominal CT: evaluation of time-density curve for the aorta, portal vein and liver
    Tatsugami, F.
    Matsuki, M.
    Inada, Y.
    Nakai, G.
    Tanikake, M.
    Yoshikawa, S.
    Narabayashi, I.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (952) : 231 - 234