Impact on stereo-acuity of two presbyopia correction approaches: monovision and small aperture inlay

被引:33
作者
Fernandez, Enrique J. [1 ]
Schwarz, Christina [1 ]
Prieto, Pedro M. [1 ]
Manzanera, Silvestre [1 ]
Artal, Pablo [1 ]
机构
[1] Univ Murcia, Lab Opt, Inst Univ Invest Opt & Nanofis, E-30100 Murcia, Spain
关键词
OPTICS VISUAL SIMULATOR; CORNEAL INLAY; ADAPTIVE OPTICS; SURGICAL-CORRECTION; INTEROCULAR DIFFERENCES; BINOCULAR SUMMATION; OCULAR ABERRATIONS; INTRACORNEAL INLAY; SPATIAL-FREQUENCY; PHASE MODULATOR;
D O I
10.1364/BOE.4.000822
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Some of the different currently applied approaches that correct presbyopia may reduce stereovision. In this work, stereo-acuity was measured for two methods: (1) monovision and (2) small aperture inlay in one eye. When performing the experiment, a prototype of a binocular adaptive optics vision analyzer was employed. The system allowed simultaneous measurement and manipulation of the optics in both eyes of a subject. The apparatus incorporated two programmable spatial light modulators: one phase-only device using liquid crystal on silicon technology for wavefront manipulation and one intensity modulator for controlling the exit pupils. The prototype was also equipped with a stimulus generator for creating retinal disparity based on two micro-displays. The three-needle test was programmed for characterizing stereo-acuity. Subjects underwent a two-alternative forced-choice test. The following cases were tested for the stimulus placed at distance: (a) natural vision; (b) 1.5 D monovision; (c) 0.75 D monovision; (d) natural vision and small pupil; (e) 0.75 D monovision and small pupil. In all cases the standard pupil diameter was 4 mm and the small pupil diameter was 1.6 mm. The use of a small aperture significantly reduced the negative impact of monovision on stereopsis. The results of the experiment suggest that combining micro-monovision with a small aperture, which is currently being implemented as a corneal inlay, can yield values of stereoacuity close to those attained under normal binocular vision. (C) 2013 Optical Society of America
引用
收藏
页码:822 / 830
页数:9
相关论文
共 38 条
[1]   Influence of interocular differences in the Strehl ratio on binocular summation [J].
Castro, Jose J. ;
Jimenez, Jose R. ;
Hita, Enrique ;
Ortiz, Carolina .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2009, 29 (03) :370-374
[2]   Interactions of spatial frequency and unequal monocular contrasts in stereopsis [J].
Cormack, LK ;
Stevenson, SB ;
Landers, DD .
PERCEPTION, 1997, 26 (09) :1121-1136
[3]   Reading Performance After Implantation of a Modified Corneal Inlay Design for the Surgical Correction of Presbyopia: 1-Year Follow-up [J].
Dexl, Alois K. ;
Seyeddain, Orang ;
Riha, Wolfgang ;
Hohensinn, Melchior ;
Rueckl, Theresa ;
Hitzl, Wolfgang ;
Grabner, Guenther .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (05) :994-1001
[4]   Monovision: a review [J].
Evans, Bruce J. W. .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2007, 27 (05) :417-439
[5]   Ocular aberrations as a function of wavelength in the near infrared measured with a femtosecond laser [J].
Fernández, EJ ;
Unterhuber, A ;
Prieto, PM ;
Hermann, B ;
Drexler, W ;
Artal, P .
OPTICS EXPRESS, 2005, 13 (02) :400-409
[6]  
Fernández EJ, 2002, J REFRACT SURG, V18, pS634
[7]   Adaptive optics binocular visual simulator to study stereopsis in the presence of aberrations [J].
Fernandez, Enrique J. ;
Prieto, Pedro M. ;
Artal, Pablo .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2010, 27 (11) :A48-A55
[8]   Binocular adaptive optics visual simulator [J].
Fernandez, Enrique J. ;
Prieto, Pedro M. ;
Artal, Pablo .
OPTICS LETTERS, 2009, 34 (17) :2628-2630
[9]   Wave-aberration control with a liquid crystal on silicon (LCOS) spatial phase modulator [J].
Fernandez, Enrique J. ;
Prieto, Pedro M. ;
Artal, Pablo .
OPTICS EXPRESS, 2009, 17 (13) :11013-11025
[10]   Ocular aberrations up to the infrared range: from 632.8 to 1070 nm [J].
Fernandez, Enrique J. ;
Artal, Pablo .
OPTICS EXPRESS, 2008, 16 (26) :21199-21208