Macroscopic and microscopic X-ray dose mappings with CCD-based GafChromic film dosimeters

被引:0
作者
Nariyama, Nobuteru [1 ]
机构
[1] Japan Synchrotron Radiat Res Inst, Sayo, Hyogo 6795198, Japan
关键词
GafChromic film; Dose; Microscopic; CCD; LED; MICROBEAM;
D O I
10.1016/j.apradiso.2011.12.009
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Charge-coupled device (CCD) digital cameras have been used to expand the application area of conventional dosimeters to two-dimensional dose measurements. Although film dosimeters are normally read with scanners, CCD reading has several advantages over scanner reading: quick reading, interference filters, and no influence from the film orientation at the reading. Moreover, the lens and light source are changeable, which makes it possible to use a wide selection of dose ranges and spatial resolutions from microscopic to macroscopic. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1214 / 1218
页数:5
相关论文
共 8 条
  • [1] [Anonymous], 1998, 63 AAPM
  • [2] Dose and absorption spectra response of EBT2 Gafchromic film to high energy x-rays
    Butson, M. J.
    Cheung, T.
    Yu, P. K. N.
    Alnawaf, H.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (04) : 196 - 202
  • [3] Responses of GafChromic films for distribution of extremely high doses from synchrotron radiation
    Nariyama, N
    [J]. APPLIED RADIATION AND ISOTOPES, 2005, 62 (05) : 693 - 697
  • [4] Spectromicroscopic film dosimetry for high-energy microbeam from synchrotron radiation
    Nariyama, Nobuteru
    Ohigashi, Takuji
    Umetani, Keiji
    Shinohara, Kunio
    Tanaka, Hiroki
    Maruhashi, Akira
    Kashino, Genro
    Kurihara, Ai
    Kondob, Takeshi
    Fukumoto, Manabu
    Ono, Koji
    [J]. APPLIED RADIATION AND ISOTOPES, 2009, 67 (01) : 155 - 159
  • [5] Salvat F., 2009, PENELOPE-2008: A code system for Monte Carlo simulation of electron and photon transport
  • [6] MICROBEAM RADIATION-THERAPY
    SLATKIN, DN
    SPANNE, P
    DILMANIAN, FA
    SANDBORG, M
    [J]. MEDICAL PHYSICS, 1992, 19 (06) : 1395 - 1400
  • [7] Radiation damage to accelerator components of SPring-8 storage ring
    Tsumaki, K.
    Matsui, S.
    Oishi, A.
    Taniuchi, Y.
    [J]. RADIATION MEASUREMENTS, 2006, 41 : S265 - S270
  • [8] A narrow microbeam is more effective for tumor growth suppression than a wide microbeam: an in vivo study using implanted human glioma cells
    Uyama, Atsushi
    Kondoh, Takeshi
    Nariyama, Nobuteru
    Umetani, Keiji
    Fukumoto, Manabu
    Shinohara, Kunio
    Kohmura, Eiji
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2011, 18 : 671 - 678