Retrofit of Non-Ductile RC Frames with Precast Concrete (PC) Wall Panels

被引:15
|
作者
Baran, Mehmet [1 ]
Tankut, Tugrul [2 ]
机构
[1] Kirikkale Univ, Dept Civil Engn, TR-71450 Kirikkale, Turkey
[2] Middle E Tech Univ, Dept Civil Engn, TR-06531 Ankara, Turkey
关键词
strengthening; reinforced concrete frames; precast concrete panels; lap splice; INFILLED FRAMES; STRENGTH;
D O I
10.1260/1369-4332.14.6.1149
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An economic, structurally effective and practically applicable strengthening method had been developed for reinforced concrete (RC) framed buildings. This study presents the test results on strengthening of deficient RC frames by using high strength precast concrete (PC) panels. The idea of the method is to convert the existing hollow brick infill wall into a load carrying system by bonding PC panels on to the plastered hollow brick infills. For this purpose, six (two reference and four strengthened) one-third scale, one bay, two storey deficient RC frames were tested under reversed-cyclic lateral loads. Test frames were designed and constructed with common deficiencies observed in practice. Panels having two different shapes were used as strengthening agencies. Test results showed that both strength and stiffness of the test frames were significantly improved by the introduction of PC panels. Experimental results were compared with the analytical approaches suggested by the authors.
引用
收藏
页码:1149 / 1166
页数:18
相关论文
共 50 条
  • [31] Historic Desmond Building Retrofit-A Case Study of the Seismic Retrofit of a Non-Ductile Concrete Building in the Los Angeles Area
    Jiang, Z.
    Sarkisian, M.
    Mathias, N.
    Garai, R.
    Lyrenmann, J.
    IMPROVING THE SEISMIC PERFORMANCE OF EXISTING BUILDINGS AND OTHER STRUCTURES 2015, 2015, : 173 - 184
  • [32] Experimental study on the efficiency of tapered strip dampers for the seismic retrofitting of damaged non-ductile RC frames
    Vafaei, Mohammadreza
    Sheikh, Abdirahman Mursal Omar
    Alih, Sophia C.
    ENGINEERING STRUCTURES, 2019, 199
  • [33] Fragility curves for non-ductile reinforced concrete frames that exhibit different component response mechanisms
    Jeon, Jong-Su
    Lowes, Laura N.
    DesRoches, Reginald
    Brilakis, Ioannis
    ENGINEERING STRUCTURES, 2015, 85 : 127 - 143
  • [34] Optimum retrofit strategy of FRP column jacketing system for non-ductile RC building frames using artificial neural network and genetic algorithm hybrid approach
    Shin, Jiuk
    Park, Sangki
    Journal of Building Engineering, 2022, 57
  • [35] Optimum retrofit strategy of FRP column jacketing system for non-ductile RC building frames using artificial neural network and genetic algorithm hybrid approach
    Shin, Jiuk
    Park, Sangki
    JOURNAL OF BUILDING ENGINEERING, 2022, 57
  • [36] Precast prestressed concrete frames for seismically retrofitting existing RC frames
    Kurosawa, Ryotaro
    Sakata, Hiroyasu
    Qu, Zhe
    Suyama, Takashi
    ENGINEERING STRUCTURES, 2019, 184 : 345 - 354
  • [37] Flexural performance of precast concrete insulated wall panels with various configurations of ductile shear ties
    Gombeda, Matthew J.
    Naito, Clay J.
    Quiel, Spencer E.
    JOURNAL OF BUILDING ENGINEERING, 2021, 33
  • [38] Loadbearing architectural precast concrete wall panels
    Freedman, S
    PCI JOURNAL, 1999, 44 (05): : 92 - 115
  • [39] Bowing of insulated precast concrete wall panels
    Losch, E
    PCI JOURNAL, 2003, 48 (06): : 126 - 129
  • [40] DESIGN OF JOINTS IN PRECAST CONCRETE WALL PANELS
    SCHUTZ, RJ
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1966, 11 (05): : 60 - &