Clinical Implications of Distal Embolization During Coronary Interventional Procedures in Patients With Acute Myocardial Infarction Quantitative Study With Doppler Guidewire

被引:43
作者
Okamura, Atsunori [1 ]
Ito, Hiroshi [1 ]
Iwakura, Katsuomi [1 ]
Kurotobi, Toshiya [1 ]
Koyama, Yasushi [1 ]
Date, Motoo [1 ]
Higuchi, Yoshiharu [1 ]
Inoue, Koichi [1 ]
Fujii, Kenshi [1 ]
机构
[1] Sakurabashi Watanabe Hosp, Div Cardiol, Kita Ku, Osaka 5300001, Japan
关键词
D O I
10.1016/j.jcin.2008.03.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study sought to investigate the timing and amount of embolic particles generation during the percutaneous coronary intervention (PCI) procedure and studied the relationship between embolic burden and coronary blood flow and myocardial damage. Background Distal embolization is a major complication of PCI. The Doppler guidewire (DGW) can detect the embolic particles as high-intensity transient signals (HITS) during the PCI procedure. Methods We prospectively studied 37 patients with acute myocardial infarction (MI). Under monitoring with the DGW, we performed first and second balloon angioplasty, followed by stenting and post-high-pressure dilatation. Left ventricular ejection fraction (LVEF) (%) and regional wall motion (RWM) (standard deviation/chord) were measured on days 1 and 22. Results The HITS were detected in 35 of 37 patients. The number of HITS was the greatest after stenting (16 +/- 18) followed by first balloon inflation (5 +/- 4). There was a significant correlation between the total number of HITS and the corrected Thrombolysis In Myocardial Infarction frame count (r = 0.52, p = 0.003) and a significant weak inverse correlation between the total number of HITS and changes in LVEF and RWM (r = 0.37, p = 0.03 and r = 0.35, p = 0.04, respectively). Conclusions Distal embolization is common during PCI in patients with acute MI, and the majority of HITS were observed after stenting. An increase in the total number of HITS is associated with reduced coronary blood flow, and is weakly associated with poor recovery of left ventricular function. (J Am Coll Cardiol Intv 2008;1:268-76) (C) 2008 by the American College of Cardiology Foundation
引用
收藏
页码:268 / 276
页数:9
相关论文
共 16 条
[1]   Effect of the distal-balloon protection system on microembolization during carotid stenting [J].
Al-Mubarak, N ;
Roubin, GS ;
Vitek, JJ ;
Iyer, SS ;
New, G ;
Leon, MB .
CIRCULATION, 2001, 104 (17) :1999-2002
[2]   Detection of coronary microembolisation by Doppler ultrasound during percutaneous coronary interventions [J].
Bahrmann, P ;
Figulla, HR ;
Wagner, M ;
Ferrari, M ;
Voss, A ;
Werner, GS .
HEART, 2005, 91 (09) :1186-1192
[3]   Detection of coronary microembolization by Doppler ultrasound in patients with stable angina pectoris undergoing elective percutaneous coronary interventions [J].
Bahrmann, Philipp ;
Werner, Gerald S. ;
Heusch, Gerd ;
Ferrari, Markus ;
Poerner, Tudor C. ;
Voss, Andreas ;
Figulla, Hans R. .
CIRCULATION, 2007, 115 (05) :600-608
[4]   TIMI frame count: A quantitative method of assessing coronary artery flow [J].
Gibson, CM ;
Cannon, CP ;
Daley, WL ;
Dodge, JT ;
Alexander, B ;
Marble, SJ ;
McCabe, CH ;
Raymond, L ;
Fortin, T ;
Poole, WK ;
Braunwald, E .
CIRCULATION, 1996, 93 (05) :879-888
[5]   ROLE OF ADENOSINE IN HYPEREMIC RESPONSE OF CORONARY BLOOD-FLOW IN MICROEMBOLIZATION [J].
HORI, M ;
INOUE, M ;
KITAKAZE, M ;
KORETSUNE, Y ;
IWAI, K ;
TAMAI, J ;
ITO, H ;
KITABATAKE, A ;
SATO, T ;
KAMADA, T .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (03) :H509-H518
[6]   Intravenous nicorandil can preserve microvascular integrity and myocardial viability in patients with reperfused anterior wall myocardial infarction [J].
Ito, H ;
Taniyama, Y ;
Iwakura, K ;
Nishikawa, N ;
Masuyama, T ;
Kuzuya, T ;
Hori, M ;
Higashino, Y ;
Fujii, K ;
Minamino, T .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (03) :654-660
[7]   LACK OF MYOCARDIAL PERFUSION IMMEDIATELY AFTER SUCCESSFUL THROMBOLYSIS - A PREDICTOR OF POOR RECOVERY OF LEFT-VENTRICULAR FUNCTION IN ANTERIOR MYOCARDIAL-INFARCTION [J].
ITO, H ;
TOMOOKA, T ;
SAKAI, N ;
YU, H ;
HIGASHINO, Y ;
FUJII, K ;
MASUYAMA, T ;
KITABATAKE, A ;
MINAMINO, T .
CIRCULATION, 1992, 85 (05) :1699-1705
[8]   THE BEHAVIOR OF SONICATED ALBUMIN MICROBUBBLES WITHIN THE MICROCIRCULATION - A BASIS FOR THEIR USE DURING MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY [J].
KELLER, MW ;
SEGAL, SS ;
KAUL, S ;
DULING, B .
CIRCULATION RESEARCH, 1989, 65 (02) :458-467
[9]   Detection of embolic particles with the Doppler guide wire during coronary intervention in patients with acute myocardial infarction - Efficacy of distal protection device [J].
Okamura, A ;
Ito, H ;
Iwakura, K ;
Kawano, S ;
Inoue, K ;
Maekawa, Y ;
Ogihara, T ;
Fujii, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (02) :212-215
[10]   Detection and quantification of embolic particles during percutaneous coronary intervention to stable plaque: It correlates to coronary flow dynamics and myocardial damage [J].
Okamura, Atsunori ;
Ito, Hiroshi ;
Iwakura, Katsuomi ;
Kawano, Shigeo ;
Kurotobi, Toshiya ;
Date, Motoo ;
Inoue, Koichi ;
Ogihara, Toshio ;
Fujii, Kenshi .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (03) :425-431