Quartz tuning fork based sensor for detection of volatile organic compounds: towards breath analysis

被引:7
作者
Sampson, Abraham [1 ]
Panchal, Suresh [1 ]
Phadke, Apoorva [1 ]
Kashyap, A. [1 ]
Suman, Jilma [1 ]
Unnikrishnan, G. [1 ]
Datar, Suwarna [1 ]
机构
[1] Def Inst Adv Technol, Dept Appl Phys, Pune 411021, Maharashtra, India
来源
MATERIALS RESEARCH EXPRESS | 2018年 / 5卷 / 04期
关键词
breath analysis; quartz tuning fork; volatile organic compounds; linear discriminants analysis (LDA); EXHALED NITRIC-OXIDE; ELECTRONIC NOSE; LUNG-CANCER; BIOMARKERS; DISEASES; AMMONIA;
D O I
10.1088/2053-1591/aabbd2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Several volatile organic compounds (VOCs) are present in the exhaled human breath whose concentration can vary depending on the physiological changes occurring within a human being. These changes in the concentration or the occurrence of a particular VOC can be used as signature of a particular disease in a person. In the present work, a sensor has been developed to detect VOCs such as 1,4-dimethoxy-2,3-butanediol (BD), and cyclohexanone (CH), acetone, methanol and ethanol. Except for BD and CH, the rest of the VOCs are present in a healthy person in ppm levels. CH and BD have been reported to be present in the exhaled human breath of breast cancer patients in ppm levels and can be used to distinguish between a healthy person and a person with breast cancer. The selectivity of the sensor towards these two compounds in the presence of other VOCs commonly present in human breath like acetone, ethanol and methanol has been studied. The sensor has been developed using modified Quartz Tuning Forks (QTFs) with the intent of developing an array of such sensors identifying different VOCs present in a healthy human's breath. Two differently modified QTFs have been used to detect 1 ppm of 1,4-dimethoxy-2,3-butanediol and 20 ppm of cyclohexanone. Linear Discriminants Analysis (LDA) has been used to classify seven different VOCs. For this purpose, features extracted from sensor responses -shift in resonant frequency, response time and recovery time of the sensors-have been used as features in the model. Differently modified array of QTFs along with the use of LDA can be a useful pathway towards development of a QTF based sensor array for human breath analysis.
引用
收藏
页数:10
相关论文
共 50 条
[21]   Analysis of CNT-based SAW sensor for the detection of volatile organic compounds [J].
Tiwary, Ashish ;
Kumar, Jitendra ;
Behera, Basudeba .
PHYSICA B-CONDENSED MATTER, 2023, 669
[22]   Breath analysis by optical fiber sensor for the determination of exhaled organic compounds with a view to diagnostics [J].
Silva, Lurdes I. B. ;
Freitas, Ana C. ;
Rocha-Santos, Teresa A. P. ;
Pereira, M. E. ;
Duarte, Armando C. .
TALANTA, 2011, 83 (05) :1586-1594
[23]   Detection of volatile organic compounds in exhaled breath to screen lung cancer: a systematic review [J].
Hua, Qingling ;
Zhu, Yanzhe ;
Liu, Hu .
FUTURE ONCOLOGY, 2018, 14 (16) :1647-1662
[24]   An LDA based sensor selection approach used in breath analysis system [J].
Guo, Dongmin ;
Zhang, David ;
Zhang, Lei .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (01) :265-274
[25]   A comprehensive meta-analysis and systematic review of breath analysis in detection of COVID-19 through Volatile organic compounds [J].
Long, Grace A. ;
Xu, Qian ;
Sunkara, Jahnavi ;
Woodbury, Reagan ;
Brown, Katherine ;
Huang, Justin J. ;
Xie, Zhenzhen ;
Chen, Xiaoyu ;
Fu, Xiao-an ;
Huang, Jiapeng .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2024, 109 (03)
[26]   Volatile Organic Compounds in Exhaled Breath in a Healthy Population: Effect of Tobacco Smoking [J].
Javier Jareno-Esteban, Jose ;
Angeles Munoz-Lucas, M. ;
Carrillo-Aranda, Belen ;
Angel Maldonado-Sanz, Jose ;
de Granda-Orive, Ignacio ;
Aguilar-Ros, Antonio ;
Civera-Tejuca, Concepcion ;
Gutierrez-Ortega, Carlos ;
Miguel Callol-Sanchez, Luis .
ARCHIVOS DE BRONCONEUMOLOGIA, 2013, 49 (11) :457-461
[27]   Detection of volatile organic compounds (VOCs) from exhaled breath as noninvasive methods for cancer diagnosis [J].
Sun, Xiaohua ;
Shao, Kang ;
Wang, Tie .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (11) :2759-2780
[28]   Dynamic Responses of Electrically Driven Quartz Tuning Fork and qPlus Sensor: A Comprehensive Electromechanical Model for Quartz Tuning Fork [J].
Lee, Manhee ;
Kim, Bongsu ;
An, Sangmin ;
Jhe, Wonho .
SENSORS, 2019, 19 (12)
[29]   Low frequency quartz tuning fork as hydrogen sensor [J].
Feng, Chaofan ;
Zifarelli, Andrea ;
Menduni, Giansergio ;
Sampaolo, Angelo ;
Wu, Hongpeng ;
Dong, Lei ;
Spagnolo, Vincenzo ;
Patimisco, Pietro .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 96 :763-770
[30]   Analysis of Exhaled Breath Volatile Organic Compounds in Inflammatory Bowel Disease: A Pilot Study [J].
Hicks, Lucy C. ;
Huang, Juzheng ;
Kumar, Sacheen ;
Powles, Sam T. ;
Orchard, Timothy R. ;
Hanna, George B. ;
Williamsa, Horace R. T. .
JOURNAL OF CROHNS & COLITIS, 2015, 9 (09) :731-737