Intralenticular foreign body: A case report and literature review

被引:7
作者
Lin, Yen-Chun [1 ]
Kuo, Chin-Liang [1 ]
Chen, Yan-Ming [1 ,2 ]
机构
[1] I Shou Univ, E Da Hosp, Dept Ophthalmol, 1 E Da Rd, Kaohsiung 824, Taiwan
[2] Natl Taiwan Univ Hosp, Dept Ophthalmol, Taipei, Taiwan
关键词
Intralenticular foreign body; intraocular foreign body; metal foreign body; TRAUMATIC CATARACT; BODIES;
D O I
10.4103/tjo.tjo_88_18
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this manuscript was to provide a better understanding of patients with intralenticular foreign bodies (FBs) and also to review the reported cases, including clinical presentation, diagnosis, management, and visual outcome. A 50-year-old male was referred to our clinic with suspected intraocular FB. Under slit-lamp examination, a full-thickness corneal wound with localized corneal edema at the temporal lower peri-limbal area was revealed. Seidel test did not indicate any wound leakage. The corresponding iris was depigmented, but there was no penetrating hole. The anterior chamber was deep with cells, but the lens, vitreous, and fundus were normal. B-scan ultrasonography and orbital computed tomography were performed, but no intraocular FB was detected. On the 2nd day, a zonal cortical cataract and posterior subcapsular cataract formed rapidly. Left-eye bare vision dramatically decreased from 20/100 to counting fingers. One month later, the patient received elective extracapsular cataract extraction. A fine metal thread was completely embedded in the lens; the lens and FB were removed together during the operation. The posterior capsule was not injured; an intraocular lens was implanted in the capsular bag. Two months postoperatively, left-eye vision had returned to 20/25. No adverse events were noted during the follow-up period. In addition to the case report, some 28 previously reported cases of intralenticular FB are reviewed here. Patient demographics, time and course of management, and visual outcome are all summarized and compared.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 21 条
[1]  
Arora R, 2000, Indian J Ophthalmol, V48, P119
[2]  
BISHARA SA, 1985, ANN OPHTHALMOL, V17, P760
[3]   Intralenticular metallic foreign body [J].
Cazabon, S ;
Dabbs, TR .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12) :2233-2234
[4]  
Chang Young Suk, 2008, Korean J Ophthalmol, V22, P272, DOI 10.3341/kjo.2008.22.4.272
[5]   Intralenticular foreign body: a D-Day reminder [J].
Dhawahir-Scala, FE ;
Kamal, A .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (06) :659-660
[6]   Metallic intraocular foreign bodies: Characteristics, interventions, and prognostic factors for visual outcome and globe survival [J].
Ehlers, Justis P. ;
Kunimoto, Derek Y. ;
Ittoop, Sabita ;
Maguire, Joseph I. ;
Ho, Allen C. ;
Regillo, Carl D. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (03) :427-433
[7]   AN INTRALENTICULAR FOREIGN-BODY AND A CLEAR LENS [J].
FOSS, AJE ;
FORBES, JE ;
MORGAN, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (12) :828-828
[8]   A case of a retained intralenticular foreign body for two years [J].
Guler, Mete ;
Yilmaz, Turgut ;
Yigit, Mehmet ;
Ulku, Gulsen ;
Arslan, Sermal .
CLINICAL OPHTHALMOLOGY, 2010, 4 :955-957
[9]   Traumatic cataract and intralenticular foreign body [J].
Kumar, A ;
Kumar, V ;
Dapling, RB .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (06) :660-661
[10]  
Lee Jang-Hun, 2014, Korean J Ophthalmol, V28, P423, DOI 10.3341/kjo.2014.28.5.423