Revision total hip arthroplasty performed with a contemporary alumina-on-alumina bearing surface; Minimum 5-year follow-up study

被引:1
作者
Yoo, JJ [1 ]
Kim, HJ [1 ]
Kim, YM [1 ]
Yoon, KS [1 ]
Koo, KH [1 ]
Nam, KW [1 ]
Shing, SI [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthoped Surg, Seoul 110744, South Korea
来源
BIOCERAMICS 18, PTS 1 AND 2 | 2006年 / 309-311卷
关键词
alumina; ceramic; revision; total hip arthroplasty; bearing surface; wear; osteolysis;
D O I
10.4028/www.scientific.net/KEM.309-311.1353
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Limitation in liner and head options available to the surgeon may be the most practical disadvantage of alumina-on-alumina total hip arthroplasty (THA). This may be more problematic in the revision THA. We evaluated the results of 57 revision THAs (average, 46.2 years old) performed with a contemporary alumina-on-alumina bearing surface after a 5-year minimum follow-up (average, 67 months; range, 60-85 months). A third generation alumina-on-alumina bearing (BIOLOX (R) forte, CeramTec AG) and a cementless PLASMACUP (R)-BiCONTACT (R) hip revision system (AESCULAP AG & Co.) had been used in all patients. Alumina bearing was chosen for a relatively young active patient in whom an acetabular bone defect was not severe and an extremely long neck of artificial head was not required for the restoration of hip joint mechanics. The average Harris hip score improved from 65.0 points to 88.9 points. No implant loosened, no stem or cup was re-revised, and no additional reoperations were required. Ceramic wear was undetectable in 14 hips where differentiation of the femoral head from the cup was possible on radiographs and no osteolysis was observed. During the follow-up period, no hip demonstrated signs of infection or ceramic failure. Short-term results of revision THAs performed with an alumina-on-alumina bearing are encouraging. We believe that physiological age and activity level of a patient, severity of acetabular bone loss, and availability of alumina head and liner options required for the restoration of proper limb length and joint stability should be considered to choose this alumina bearing surface during the revision THA.
引用
收藏
页码:1353 / 1356
页数:4
相关论文
共 50 条
  • [11] Highly Cross-Linked Polyethylene in Total Hip Arthroplasty for Osteonecrosis of the Femoral Head: A Minimum 5-Year Follow-Up Study
    Min, Byung-Woo
    Lee, Kyung-Jae
    Song, Kwang-Soon
    Bae, Ki-Cheor
    Cho, Chul-Hyun
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03) : 526 - 530
  • [12] Uncemented total hip arthroplasty using alumina ceramic bearings at a minimum of 14 years of follow-up
    Sachiyuki Tsukada
    Motohiro Wakui
    Kazuha Kizaki
    Takuya Iseki
    Masunao Miyao
    Atsushi Tasaki
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 1689 - 1695
  • [13] Total hip arthroplasty after surgical treatment of acetabular fractures : a 5-year minimum follow-up study
    Ordas-Bayon, Alejandro
    Godoy Monzon, Daniel
    Cid Casteulani, Alberto
    Buttaro, Martin
    Diaz Dilernia, Fernando
    Piccaluga, Francisco
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (ES1): : 52 - 59
  • [14] Epidemiology of Dislocation Following Direct Anterior Total Hip Arthroplasty: A Minimum 5-Year Follow-Up Study
    Tamaki, Tatsuya
    Oinuma, Kazuhiro
    Miura, Yoko
    Higashi, Hidetaka
    Kaneyama, Ryutaku
    Shiratsuchi, Hideaki
    JOURNAL OF ARTHROPLASTY, 2016, 31 (12) : 2886 - 2888
  • [15] Use of a Modular Tapered Fluted Femoral Component in Revision Total Hip Arthroplasty Following Resection of a Previously Infected Total Hip: Minimum 5-year Follow-Up
    Houdek, Matthew T.
    Perry, Kevin I.
    Wyles, Cody C.
    Berry, Daniel J.
    Sierra, Rafael J.
    Trousdale, Robert T.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (03) : 435 - 438
  • [16] Uncemented total hip arthroplasty using alumina ceramic bearings at a minimum of 14 years of follow-up
    Tsukada, Sachiyuki
    Wakui, Motohiro
    Kizaki, Kazuha
    Iseki, Takuya
    Miyao, Masunao
    Tasaki, Atsushi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (07) : 1689 - 1695
  • [17] Clinical Outcomes and Bearing-Specific Complications Following Fourth-Generation Alumina Ceramic-on-Ceramic Total Hip Arthroplasty: A Single-Surgeon Series of 749 Hips at a Minimum of 5-Year Follow-Up
    Lim, Seung-Jae
    Ryu, Hyung-Gon
    Eun, Hyeon-Jun
    Park, Chan-Woo
    Kwon, Kyeu-Back
    Park, Youn-Soo
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07) : 2182 - +
  • [18] Outcomes of Ceramic- On-Ceramic Bearing Total Hip Arthroplasty: A Minimum 10-Year Follow-Up Study
    Alshammari, Malek O.
    de Petrillo, Gianni
    Epure, Laura M.
    Huk, Olga L.
    Zukor, David J.
    Antoniou, John
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07) : S146 - S151
  • [19] Revision of Failed Total Hip Arthroplasty Acetabular Cups to Porous Tantalum Components A 5-Year Follow-Up Study
    Fernandez-Fairen, Mariano
    Murcia, Antonio
    Blanco, Agustin
    Merono, Antonio
    Murcia, Antonio, Jr.
    Ballester, Jorge
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06) : 865 - 872
  • [20] Monobloc Dual Mobility With a Minimum 5-Year Follow-Up: A Safe and Effective Solution in Primary Total Hip Arthroplasty
    Gkiatas, Ioannis
    Tarity, T. David
    Nocon, Allina A.
    Verwiel, Chloe P.
    Xiang, William
    Malahias, Michael-Alexander
    Sculco, Peter K.
    Sculco, Thomas P.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (01) : 83 - 88