Revision total hip arthroplasty performed with a contemporary alumina-on-alumina bearing surface; Minimum 5-year follow-up study

被引:1
作者
Yoo, JJ [1 ]
Kim, HJ [1 ]
Kim, YM [1 ]
Yoon, KS [1 ]
Koo, KH [1 ]
Nam, KW [1 ]
Shing, SI [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Orthoped Surg, Seoul 110744, South Korea
来源
BIOCERAMICS 18, PTS 1 AND 2 | 2006年 / 309-311卷
关键词
alumina; ceramic; revision; total hip arthroplasty; bearing surface; wear; osteolysis;
D O I
10.4028/www.scientific.net/KEM.309-311.1353
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Limitation in liner and head options available to the surgeon may be the most practical disadvantage of alumina-on-alumina total hip arthroplasty (THA). This may be more problematic in the revision THA. We evaluated the results of 57 revision THAs (average, 46.2 years old) performed with a contemporary alumina-on-alumina bearing surface after a 5-year minimum follow-up (average, 67 months; range, 60-85 months). A third generation alumina-on-alumina bearing (BIOLOX (R) forte, CeramTec AG) and a cementless PLASMACUP (R)-BiCONTACT (R) hip revision system (AESCULAP AG & Co.) had been used in all patients. Alumina bearing was chosen for a relatively young active patient in whom an acetabular bone defect was not severe and an extremely long neck of artificial head was not required for the restoration of hip joint mechanics. The average Harris hip score improved from 65.0 points to 88.9 points. No implant loosened, no stem or cup was re-revised, and no additional reoperations were required. Ceramic wear was undetectable in 14 hips where differentiation of the femoral head from the cup was possible on radiographs and no osteolysis was observed. During the follow-up period, no hip demonstrated signs of infection or ceramic failure. Short-term results of revision THAs performed with an alumina-on-alumina bearing are encouraging. We believe that physiological age and activity level of a patient, severity of acetabular bone loss, and availability of alumina head and liner options required for the restoration of proper limb length and joint stability should be considered to choose this alumina bearing surface during the revision THA.
引用
收藏
页码:1353 / 1356
页数:4
相关论文
共 50 条
  • [1] Contemporary alumina-on-alumina total hip arthroplasty performed in patients younger than forty years: A 5-year minimum follow-up study
    Yoo, Jeong Joon
    Kim, Young-Min
    Yoon, Kang Sup
    Koo, Kyung-Hoi
    Kim, Jong Won
    Nam, Kwang Woo
    Kim, Hee Joong
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 78B (01) : 70 - 75
  • [2] Cementless alumina-on-alumina total hip arthroplasty in patients younger than 50 years - A 5-year minimum follow-up study
    Ha, Yong-Chan
    Koo, Kyung-Hoi
    Jeong, Soon-Taek
    Yoo, Jeong Joon
    Kim, Young-Min
    Kim, Hee Joong
    JOURNAL OF ARTHROPLASTY, 2007, 22 (02) : 184 - 188
  • [3] Revision Total Hip Arthroplasty Using an Alumina-On-Alumina Bearing Surface in Patients With Osteolysis
    Yoo, Jeong Joon
    Yoon, Pil Whan
    Lee, Young-Kyun
    Koo, Kyung-Hoi
    Yoon, Kang Sup
    Kim, Hee Joong
    JOURNAL OF ARTHROPLASTY, 2013, 28 (01) : 132 - 138
  • [4] Excellent results with cementless total hip arthroplasty and alumina-on-alumina pairing: minimum ten-year follow-up
    Kress, Alexander M.
    Schmidt, Rainer
    Holzwarth, Ulrich
    Forst, Raimund
    Mueller, Lutz A.
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (02) : 195 - 200
  • [5] Third-Generation Alumina-on-Alumina Total Hip Arthroplasty: 14 to 16-Year Follow-Up Study
    Kang, Bun-Jung
    Ha, Yong-Chan
    Ham, Dae-Woong
    Hwang, Sun-Chul
    Lee, Young-Kyun
    Koo, Kyung-Hoi
    JOURNAL OF ARTHROPLASTY, 2015, 30 (03) : 411 - 415
  • [6] Straight Tapered Titanium Stem With Alumina Bearing in Cementless Primary Total Hip Arthroplasty A Minimum 5-Year Follow-Up
    Hwang, Bo-Hyun
    Lee, Woo-Suk
    Park, Kwan-Kyu
    Yang, Ick-Hwan
    Han, Chang-Dong
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1310 - 1317
  • [7] Failure Analysis of Alumina on Alumina Total Hip Arthroplasty With a Layered Acetabular Component Minimum Ten-Year Follow-Up Study
    Kawano, Shunsuke
    Sonohata, Motoki
    Shimazaki, Takafumi
    Kitajima, Masaru
    Mawatari, Masaaki
    Hotokebuchi, Takao
    JOURNAL OF ARTHROPLASTY, 2013, 28 (10) : 1822 - 1827
  • [8] A Minimum Ten Years of Follow-Up of Alumina Head on Delta Liner Total Hip Arthroplasty
    Choy, Won-sik
    Cha, Yong-han
    Jeon, Chung-youb
    Lee, Kyu-sang
    Kim, Ha-yong
    JOURNAL OF ARTHROPLASTY, 2018, 33 (02) : 470 - 476
  • [9] Minimum 5-Year Follow-Up of a Cementless, Modular, Tapered Stem in Hip Revision Arthroplasty
    Weiss, Rudiger J.
    Beckman, Mats O.
    Enocson, Anders
    Schmalholz, Anders
    Stark, Andre
    JOURNAL OF ARTHROPLASTY, 2011, 26 (01) : 16 - 23
  • [10] Total Hip Arthroplasty Performed with a Novel Design Type 1 Femoral Stem: A Retrospective Minimum 5-Year Follow-up Study
    Yang, Hanbual
    Kim, Kangbaek
    Kim, Hong Seok
    Yoo, Jeong Joon
    CLINICS IN ORTHOPEDIC SURGERY, 2022, 14 (01) : 28 - 34