Photoacoustic imaging using a two-dimensional CMUT array

被引:0
作者
Wygant, IO [1 ]
Zhuang, X [1 ]
Kuo, PS [1 ]
Yeh, DT [1 ]
Oralkan, O [1 ]
Khuri-Yakub, BT [1 ]
机构
[1] Stanford Univ, Edward L Ginzton Lab, Stanford, CA 94305 USA
来源
2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 | 2005年
关键词
photoacoustics; capacitive micromachined ultrasonic transducer; CMUT; three-dimensional; integrated electronics;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Photoacoustic imaging is a promising complement to pulse-echo ultrasound imaging because it provides contrast between areas with different light absorption characteristics. Specifically, regions with higher blood concentration can be identified, which is useful for imaging vascularization and the early detection of cancer. Here we present volumetric photoacoustic images of a vessel-like phantom. The phantom consists of three 1.3-mm diameter tubes inside a tissue mimicking material. The center tube is filled with ink to provide optical contrast. A two-dimensional capacitive micromachined ultrasonic transducer (CMUT) array is used for acoustic detection. The use of a two-dimensional transducer array eliminates the drawbacks of a mechanically scanned system and enables volumetric imaging. CMUT technology enables new types of transducer arrays that would benefit photoacoustic imaging. Fully populated two-dimensional arrays, annular ring-arrays, and high-frequency arrays have all been demonstrated using CMUT technology and have advantages for photoacoustic imaging systems. Other advantages of CMUT technology for photoacoustic imaging include a wider bandwidth than comparable piezoelectric devices and ease of integration with electronics.
引用
收藏
页码:1921 / 1924
页数:4
相关论文
共 8 条
[1]   Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors [J].
Esenaliev, RO ;
Karabutov, AA ;
Oraevsky, AA .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :981-988
[2]   Image reconstruction for photoacoustic scanning of tissue structures [J].
Hoelen, CGA ;
de Mul, FFM .
APPLIED OPTICS, 2000, 39 (31) :5872-5883
[3]   Three-dimensional photoacoustic imaging of blood vessels in tissue [J].
Hoelen, CGA ;
de Mul, FFM ;
Pongers, R ;
Dekker, A .
OPTICS LETTERS, 1998, 23 (08) :648-650
[4]   Volumetric ultrasound Imaging using 2-D CMUT arrays [J].
Oralkan, Ö ;
Ergun, AS ;
Cheng, CH ;
Johnson, JA ;
Karaman, M ;
Lee, TH ;
Khuri-Yakub, BT .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (11) :1581-1594
[5]  
Wang LHV, 2003, DIS MARKERS, V19, P123
[6]  
WYGANT IO, 2005, P SPIE MED IM, P26
[7]  
YEH DT, 2005, 2005 IEEE INT ULTR S
[8]  
ZHUANG X, 2005, P SPIE MED IM, P37