Highly balanced gradiometer systems based on HTS-SQUIDs for the use in magnetically unshielded environment

被引:6
作者
Borgmann, J
Rijpma, AP
ter Brake, HJM
Rogalla, H
David, P
机构
[1] Univ Twente, Fac Appl Phys, Low Temp Div, NL-7500 AE Enschede, Netherlands
[2] Univ Bonn, Inst Strahlen & Kernphys, D-53117 Bonn, Germany
关键词
D O I
10.1109/77.783827
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two different concepts for gradiometer formation were tested applying high-temperature rf SQUIDs operated at 77 K in liquid nitrogen. All gradiometer systems are fully based on magnetometers. The first concept applies a compensating magnetometer at different positions to actively cancel the magnetic field at the location of other magnetometers. These magnetometers were arranged In an axial direction. In parts, a system of superconducting plates was used to align the relative magnetic orientation of the magnetometers. The outputs of these sensors were used to form a highly balanced electronic gradiometer. The second concept Is based on electronic noise cancellation. A set of three magnetometers arranged in an axial direction was used to form an electronic second-order gradiometer. Different types of reference systems based on HTS-SQUID magnetometers and fluxgate sensors were applied to the gradiometer signal for achieving a high common mode rejection of the environmental disturbances. The performance of the different systems is demonstrated in a magnetically unshielded environment as well as in a shielded environment and the common mode rejection of homogeneous magnetic fields is measured. To demonstrate the performance of the systems, biomagnetic measurements have been performed in shielded and unshielded environments.
引用
收藏
页码:3680 / 3683
页数:4
相关论文
共 15 条
[1]  
*BART INSTR LTD, 1996, OP MAN OX8 7GE
[2]   Electronic high-temperature radio frequency superconducting quantum interference device gradiometers for unshielded environment [J].
Borgmann, J ;
David, P ;
Ockenfuss, G ;
Otto, R ;
Schubert, J ;
Zander, W ;
Braginski, AI .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07) :2730-2734
[3]   Compensation techniques for high-temperature superconducting quantum interference device gradiometers operating in unshielded environment [J].
Borgmann, J ;
David, P ;
Krause, HJ ;
Otto, R ;
Braginski, AI .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (08) :3082-3084
[4]   High-T-c superconducting gradiometer with a long baseline asymmetric flux transformer [J].
Dantsker, E ;
Froehlich, OM ;
Tanaka, S ;
Kouznetsov, K ;
Clarke, J ;
Lu, Z ;
Matijasevic, V ;
Char, K .
APPLIED PHYSICS LETTERS, 1997, 71 (12) :1712-1714
[5]   The influence of ambient magnetic environments on high-T-c superconducting quantum interference device gradiometers [J].
Keene, MN ;
Exon, NJ ;
Humphreys, RG ;
Chew, NG .
JOURNAL OF APPLIED PHYSICS, 1996, 79 (11) :8783-8791
[6]  
KOCH RH, 1993, APPL PHYS LETT, V63, P3
[7]  
PETERS MJ, 1998, COMMUNICATION
[8]  
RIJPMA AP, 1998, APPL SUP C PALM SPRI
[9]   SUPERCONDUCTING INSTRUMENTS [J].
SARWINSKI, RE .
CRYOGENICS, 1977, 17 (12) :671-679
[10]   A 2ND-ORDER SQUID GRADIOMETER OPERATING AT 77-K [J].
TAVRIN, Y ;
ZHANG, Y ;
WOLF, W ;
BRAGINSKI, AI .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1994, 7 (05) :265-268