Open-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications

被引:241
作者
Freire, Nuno M. A. [1 ,2 ]
Estima, Jorge O. [1 ,2 ]
Marques Cardoso, Antonio J. [2 ,3 ]
机构
[1] Univ Coimbra, Fac Sci & Technol, Dept Elect & Comp Engn, P-3030290 Coimbra, Portugal
[2] Inst Telecomunicacoes, P-3030290 Coimbra, Portugal
[3] Univ Beira Interior, Dept Electromech Engn, P-6201001 Covilha, Portugal
关键词
Condition monitoring; fault diagnosis; multiple power switch open-circuit faults; permanent magnet machines; semiconductor device reliability; wind power generation; OPEN-SWITCH FAULTS; PWM INVERTER; POWER ELECTRONICS; RELIABILITY; SCHEME;
D O I
10.1109/TIE.2012.2207655
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Condition monitoring and fault diagnosis are currently considered crucial means to increase the reliability and availability of wind turbines and, consequently, to reduce the wind energy cost. With similar goals, direct-drive wind turbines based on permanent magnet synchronous generators (PMSGs) with full-scale power converters are an emerging and promising technology. Numerous studies show that power converters are a significant contributor to the overall failure rate of modern wind turbines. In this context, open-circuit fault diagnosis in the two power converters of a PMSG drive for wind turbine applications is addressed in this paper. A diagnostic method is proposed for each power converter, allowing real-time detection and localization of multiple open-circuit faults. The proposed methods are suitable for integration into the drive controller and triggering remedial actions. In order to prove the reliability and effectiveness of the proposed fault diagnostic methods, several simulation and experimental results are presented.
引用
收藏
页码:3957 / 3967
页数:11
相关论文
共 48 条
[1]  
Abramik S., 2003, P EUR C POW EL APPL, P2
[2]   Switching Function Model-Based Fast-Diagnostic Method of Open-Switch Faults in Inverters Without Sensors [J].
An, Qun-Tao ;
Sun, Li-Zhi ;
Zhao, Ke ;
Sun, Li .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (01) :119-126
[3]  
[Anonymous], 2010, P 19 INT C EL MACH I
[4]   A Failure-Detection Strategy for IGBT Based on Gate-Voltage Behavior Applied to a Motor Drive System [J].
Antonio Rodriguez-Blanco, Marco ;
Claudio-Sanchez, Abraham ;
Theilliol, Didier ;
Gerardo Vela-Valdes, Luis ;
Sibaja-Teran, Pedro ;
Hernandez-Gonzalez, Leobardo ;
Aguayo-Alquicira, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1625-1633
[5]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[6]   An Observer-Based Diagnosis Scheme for Single and Simultaneous Open-Switch Faults in Induction Motor Drives [J].
Campos-Delgado, D. U. ;
Espinoza-Trejo, D. R. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (02) :671-679
[7]   Fault Diagnosis on a PWM Rectifier AC Drive System with Fault Tolerance Using the Average Current Park's Vector Approach [J].
Caseiro, J. A. A. ;
Mendes, A. M. S. ;
Marques Cardoso, A. J. .
2009 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE, VOLS 1-3, 2009, :695-701
[8]   A Review of the State of the Art of Power Electronics for Wind Turbines [J].
Chen, Zhe ;
Guerrero, Josep M. ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (08) :1859-1875
[9]   Fault detection and diagnosis in an induction machine drive: A pattern recognition approach based on concordia stator mean current vector [J].
Diallo, D ;
Benbouzid, MEH ;
Hamad, D ;
Pierre, X .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (03) :512-519
[10]   Open-Switch Fault Diagnosis and System Reconfiguration of Doubly fed Wind Power Converter Used in a Microgrid [J].
Duan, Pan ;
Xie, Kai-gui ;
Zhang, Li ;
Rong, Xianliang .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (03) :816-821